SOLICITATION NOTICE
30 -- Protective Relays
- Notice Date
- 9/23/2002
- Notice Type
- Solicitation Notice
- Contracting Office
- US Army Humphreys Engineer Center Support Activity-Military, ATTN: CEHEC-CT, 7701 Telegraph Road, Alexandria, VA 22315-3860
- ZIP Code
- 22315-3860
- Solicitation Number
- DACA72-02-T-0012
- Point of Contact
- Alandra Jones, 703-428-6551
- E-Mail Address
-
Email your questions to US Army Humphreys Engineer Center Support Activity-Military
(alandra.r.jones@usace.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- NA The Army Corps of Engineers, 249th Engineer Battalion has need of 3 ea $________ PVS-1000, frequency test set, programmable 3-phase voltage source, and calibration cetificate (3 ea $_________). This is a combined synopisi/solicitation for commericial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation: a written solicitation will not be issue d. The solicitation number is DACA72-02-T-0012, which is a request for quotation (RFQ). The solicitation incorporates provision and clauses that are in effect through Federal Acquisition Circular 01-08. Specification for the purchase of a piece of test equ ipment:Input Voltage ? 85 to 265 Volts AC 50/60 Hz Phase Reference Input Current ? 0.5 to 5 Amps Phase Reference Voltage ? 10 to 30 volts Voltage Outputs ? Ranges: 3 ?phase ramped or step function in all 3 phases 0 to 120 volts @ 60VA; 0 to 240 Volts @ 60 VA Accuracy ? From 10 to 100% of range at full load, 40 to 80 Hertz, maximum 1% Output Frequency ? Range = 10 to 500 Hertz Resolution = .001 Hertz Accuracy = Less than 50 ppm for frequencies above 40 Hertz Frequency accuracy must be linearly derated to 200 ppm at 10 hertz Dynamic Capabilities: The frequency must be able to be ramped o r a step function be available. Digital Timer ? Display six (6) digits, ranges = seconds and cycles; accuracy = +/- least significant digit or +/- .005% of reading, whichever is greater, in the seconds mode, +/- .5 cycles in the cycles mode Stop Gates ? Dry Contacts normally open and normally closed. This test equipment is going to be used along with a SR-90 Relay test set to test three-phase protective relays. It must have the following features available: a) Graphically displays voltage and phase angles to visually monitor the values for testing protective relays b) Single-phase; three-phase open delta; three-phase T-connect; three-phase Wye; and three-phase delta output of both voltages and phase angles for testing virtually all impedance r elays c) Output Voltages, Phase angles, and Frequency must be independently of simultaneously selectable and fully adjustable in performaing three-phase or phase-to-phase tests without the use of a computer d) Voltage phase angles must be adjustable from 0 to 360 degrees to provide multiple fault testing parameters and calibration settings. The following FAR provisions apply: 52.212-1, Instructions to Offerors-Commercial Items. Additional FAR and DFAR clauses are applicable: 52.212-4, 52.212-5, 52.222-26, 5 2.222-35, 52.232-33, 252.225-7001. Offeor shall include a completed copy of the provision at 52.212-3, Offeror Representation and Certifications-Commercial Items, with their quote. Reps & Certs are located at http://www.arnet.gov/far; http://farsite.hill.a f.mil; or http://www.dtic.mil/dfars. Submit quotes to the attention of Alandra Jones, fax 703-428-8181 or e-mail: Alandra.R.Jones@usace.army.mil
- Place of Performance
- Address: US Army Humphreys Engineer Center Support Activity-Military ATTN: CEHEC-CT, 7701 Telegraph Road Alexandria VA
- Zip Code: 22315-3860
- Country: US
- Zip Code: 22315-3860
- Record
- SN00173863-W 20020925/020924065422 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |