MODIFICATION

30 -- Protective Relays

Notice Date
9/27/2002
 
Notice Type
Modification
 
Contracting Office
US Army Humphreys Engineer Center Support Activity-Military, ATTN: CEHEC-CT, 7701 Telegraph Road, Alexandria, VA 22315-3860
 
ZIP Code
22315-3860
 
Solicitation Number
DACA72-02-T-0012
 
Response Due
9/30/2002
 
Point of Contact
Alandra Jones, 703-428-6551
 
E-Mail Address
Email your questions to US Army Humphreys Engineer Center Support Activity-Military
(alandra.r.jones@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
NA Specification for the purchase of a piece of test equipment: Input Voltage ? 85 to 265 Volts AC 50/60 Hz Phase Reference Input Current ? 0.5 to 5 Amps Phase Reference Voltage ? 10 to 30 volts Voltage Outputs ? Ranges: 3 ? phase ramped or step function in all 3 phases 0 to 120 volts @ 60VA; 0 to 240 Volts @ 60 VA Accuracy ? From 10 to 100% of range at full load, 40 to 80 Hertz, maximum 1% Output Frequency ? Range = 10 to 500 Hertz Resolution = .001 Hertz Accuracy = Less than 50 ppm for frequencies above 40 Hertz Frequency accuracy must be linearly derated to 200 ppm at 10 hertz Dynamic Capabilities: The frequency must be able to be ramped or a step function be available. Digital Timer ? Display six (6) digits, ranges = seconds and cycles; accuracy = +/- least significant digit or +/- .005% of reading, whichever is greater, in the seconds mode, +/- .5 cycles in the cycles mode Stop Gates ? Dry Contacts normally open and normally closed. This test equipment is going to be used along with a SR-90 Relay test set to test three-phase protective relays. It must have the following features available: a) Graphically displays voltage and phase angles to visually monitor the values for testing protective relays b) Single-phase; three-phase open delta; three-phase T-connect; three-phase Wye; and three-phase delta output of both voltages and phase angles fo r testing virtually all impedance relays c) Output Voltages, Phase angles, and Frequency must be independently of simultaneously selectable and fully adjustable in performaing three-phase or phase-to-phase tests without the use of a computer d) Voltage pha se angles must be adjustable from 0 to 360 degrees to provide multiple fault testing parameters and calibration settings.
 
Place of Performance
Address: US Army Humphreys Engineer Center Support Activity-Military ATTN: CEHEC-CT, 7701 Telegraph Road Alexandria VA
Zip Code: 22315-3860
Country: US
 
Record
SN00177670-W 20020929/020927213549 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.