Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 27, 2004 FBO #0852
SOLICITATION NOTICE

38 -- CONSTRUCTION SERVICES TO REPAIR STILLING BASIN WALLS AT WILSON DAM, RUSSELL COUNTY, KANSAS

Notice Date
3/25/2004
 
Notice Type
Solicitation Notice
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
US Army Engineer District, Kansas City, ATTN: CENWK-CT, 700 Federal Building 60l East 12th Street, Kansas City, MO 64106-2896
 
ZIP Code
64106-2896
 
Solicitation Number
W912DQ-04-B-0005
 
Response Due
5/11/2004
 
Archive Date
7/10/2004
 
Point of Contact
Rosalind M. Whitfield, (816)983-3923
 
E-Mail Address
Email your questions to US Army Engineer District, Kansas City
(rosalind.m.whitfield@nwk02.usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This procurement is a BEST VALUE Invitation For Bids for construction services and is full and open competition. Responsible offers will be evaluated on the basis of Best Value to the Government. In addition to using pricing as a determining factor, evaluation of the contractor??????s related experience and past performance will be considered. The United States Army Corps of Engineers intends to award a Firm Fixed Price Contract for construction services to repair the outlet works stilling basin walls . Repairs consist of construction of a temporary access roadway around the site, installation of low flow diversion piping and pumping system, dewatering the worksite, controlling storm water runoff and fugitive sediments, excavation of the existing backfi ll, providing support during Government inspection of the walls, and execution of one or more options. Option 1 requires installation of the backfill to original conditions, and replacement of the stilling basin wall backfill drains. Option 2 requires inst allation of an EPS wall in the backfill, installation of the backfill to original conditions, and replacement of the stilling basin wall backfill drains. Option 3 is focused on partially backfilling around the stilling basin to current conditions. Option 4 addresses the possible emergency actions necessary to restore functionality to the stilling basin in the event of the necessity to discharge water through the stilling basin. Option 5 addresses the removal of existing corrugated metal piping that may be c ontaminated with PCBs. Options 1, 2, and 3 are mutually exclusive. Only one of these options will be exercised. The magnitude of this procurement is between $1 and 5 million. The North American Industrial Classification System (NAICS) code for this project is 237990, the Standard Industrial Code (SIC) is 1629. The Small Business size standard is $27.5 Million. This solicitation is unrestricted. Bids will be accepted from all interested responsible and responsive offerors. The mandatory date of contract co mpletion is 1 December 2004. Solicitation W912DQ-04-B-0005 will be available on or about 08 April 2004. Bids will be due and opened on or about 11 May 2004. The solicitation will be issued on CD-ROM only. Hard copies will not be available. Copies of the CD -ROM will be limited to one per firm. To facilitate timely issuance, requests for copies must be made on http://www.nwk.usace.army.mil/contract/contract.html. by registering at this website. All offerors must be registered to receive CD-ROM. Plan holder lists are available only on this web site also. Do not use a post office box address. Point of contact for contractual questions and clarifications is Rosalind Whitfield, Contract Specialist/Contracting Officer, US Army Engineering District, Kansas City, Attn: CENWK-CT-C, 760 Federal Building 601 E. 12th Street, Kansas City, MO 64106, mailto: rosalind.m.whitfield@nwk02.usace.army.mil (816) 983-3923. Point of Contact for technical questions and clarifications is Randall S. Kuzniakowski, Program Manager, m ailto: Randall.S.Kuzniakowski@nwk02.usace.army.mil (816) 983-3685. No collect calls will be accepted. No telephone calls or faxes for solicitation requests will be accepted. Please reference DOD DFARS Clause 252.204-7302, ??????Required Central Contractor Registration.?????? Prospective offerors must be registered on the CCR prior to contract award. The registration form is available on the CCR web page http://www.ccr2000.com or http://www.ccr.gov you may telephone 1-888-227-2435, Contractor Registration A ssistance Center. URL http://www.nwk.usace.army.mil/contract/contract.html to register.
 
Place of Performance
Address: US Army Engineer District, Kansas City ATTN: CENWK-CT, 700 Federal Building 60l East 12th Street Kansas City MO
Zip Code: 64106-2896
Country: US
 
Record
SN00554289-W 20040327/040325212407 (fbodaily.com)
 