Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 13, 2004 FBO #0991
SOLICITATION NOTICE

66 -- 3.2mm Triple Resonance HXY MAS Solids Probe, 400 MHz

Notice Date
8/11/2004
 
Notice Type
Solicitation Notice
 
NAICS
339111 — Laboratory Apparatus and Furniture Manufacturing
 
Contracting Office
Department of Health and Human Services, National Institutes of Health, Nat'l Institute of Diabetes, Digestive, & Kidney Diseases, 2 Democracy Plaza, Suite 700W 6707 Democracy Blvd., MSC 5455, Bethesda, MD, 20892-5455
 
ZIP Code
20892-5455
 
Solicitation Number
NIH-NIDDK-04-289
 
Response Due
9/9/2004
 
Archive Date
9/24/2004
 
Point of Contact
Patricia Haun, Purchasing Agent, Phone (301) 594-8855, Fax (301) 480-4226,
 
E-Mail Address
haunp@extra.niddk.nih.gov
 
Description
The National Institutes of Health (NIH), National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) has a requirement to purchase a 3.2 mm Triple Resonance HXY MAS Solids Probe, 400 MHz from Varian Inc., 3120 Hansen Way, Palo Alto, CA 94304. The NMR probe shall meet the following specifications: 1) The probe shall be compatible with the dimensions and field strength of an existing Oxford Instruments wide-bore 9.4 Tesla magnet. 2) The probe shall be compatible with the hardware and software for control of sample spinning rates and sample temperature in an existing Varian InfinityPlus spectrometer. 3) Sample volumes shall be at least 22 microliters. 4) Sample spinning rates up to at least 25.0 kilohertz shall be possible, with stability better than one part per thousand. 5) The probe shall be capable of NMR signal detection in the 100-162 MHz frequency range on the X channel and the 40-107 MHz frequency range on the Y channel. The H channel shall operate at 376 MHz and 400 MHz frequencies. 6) The probe shall operate in double-resonance and triple-resonance modes. In triple-resonance mode, the probe shall achieve radiofrequency field strengths of 131 kHz or higher for at least 65 milliseconds on the H channel, 131 kHz or higher for at least 15 milliseconds on the X channel with carbon-13 observation, and 75 kHz or higher for at least 15 milliseconds on the Y channel with nitrogen-15 observation. In double-resonance mode, the probe shall achieve radiofrequency field strengths of 138 kHz or higher for at least 65 milliseconds on the H channel and 138 kHz or higher for at least 15 milliseconds on the X channel with carbon-13 observation, or 83 kHz or higher for at least 15 milliseconds on the X channel with nitrogen-15 observation. 7) Carbon-13 detection sensitivity, measured on the methyl carbon signal from a full rotor (22 microliters) of unlabeled hexamethylbenzene at 3.3 kHz spinning speed in four scans, shall be at least 81:1 in double-resonance mode and 54:1 in triple-resonance mode. The Institute intends to purchase this equipment by other than full and open competition from Varian, Incorporated. To the best of the Governments knowledge they are the sole manufacturer and distributor of this equipment. Interested vendors may identify in writing their interest with a capability statement to the Contracting Office prior to the closing date of this notice. This notice of intent is not a request for competitive proposals, however, all responses received, before the closing date, of this announcement will be considered by the Government. A determination by the Government not to compete this proposed acquisition is based upon responses to this notice and is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. It is anticipated that Request for Quotation (RFQ) NIH-NIDDK-04-289 will be available fifteen (15) days after the publication date of this synopsis. Receipt of quotations will be due ten (10) days after the release of the RFQ. The anticipated award date is September 15, 2004. Request for copies of the RFQ must be in writing and may be FAXED to 301-480-4226. Quotations must be submitted in writing to the National Institute of Diabetes and Digestive and Kidney Diseases 6707 Democracy Blvd., Room 774C, Bethesda, Maryland 20817 Attention: Patricia Haun. FAX quotations must contain offerors names, address, telephone number and fax number. FAX quotations will only be accepted if dated and signed by an authorized company representative.
 
Place of Performance
Address: 9000 Rockville Pike, Bethesda, MD
Zip Code: 20892
 
Record
SN00641279-W 20040813/040811211801 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.