SOLICITATION NOTICE
23 -- Trailers, Box
- Notice Date
- 8/28/2004
- Notice Type
- Solicitation Notice
- NAICS
- 423830
— Industrial Machinery and Equipment Merchant Wholesalers
- Contracting Office
- Department of Justice, Federal Bureau of Investigation, FBI Academy/Property Procurement & Management Section, HRT Building, Quantico, VA, 22135
- ZIP Code
- 22135
- Solicitation Number
- RFQ-133084
- Response Due
- 9/13/2004
- Archive Date
- 9/28/2004
- Point of Contact
- Theresa Powell, Contracting Officer, Phone 703-632-1640, Fax 703-632-1607, - Theresa Powell, Contracting Officer, Phone 703-632-1640, Fax 703-632-1607,
- E-Mail Address
-
tpowell@fbiacademy.edu, tpowell@fbiacademy.edu
- Small Business Set-Aside
- Total Small Business
- Description
- This combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The Request for Quote (RFQ) number is RFQ-133084, and is being conducted as a Small Business set-aside under the procedures of Part 12 and 13, test program, for specific model Mobile Command Post Vehicles. The North American Industrial Classification System (NAICS) number is 423830 the size standard is 500 employees. The RFQ incorporates provisions and clauses that are in effect through Federal Acquisition Circular 2001-24. The Federal Bureau of Investigation intends to award a Firm-fixed price type contract for four (4) 18? (foot) Cargo Trailers, with an Option to purchase four (4) additional cargo trailers within a 6 month period. The specifications are as follows: 18? Cargo Wagon, Base Model CW1822-102 ? 7ft body width; extended ?A? frame by 1? (foot); recessed step at side door, increase door height the length of the step; 4 each heavy duty forged lashing rings installed 1 each per corner (this is the air/sea/hurrican tie down system for the trailer); Pair of light duty rear cornerpost jacks ? 2,000lb static load capacity; 45?Wx36?Lx10?D sub-floor spare tire carrier with hinged lift up lid and locking arms (location must be discussed); three piece ?A? frame included; 2 5/16? top mount coupler with replaceable locking dog assembly; 12 volt power jack ram hoist; Department of Transportation compliant ?? safety chain with clevis safety slip hook and launch; 6?x2? rectangular steel tube mainrails with equal height ?C? section Crossmembers and Outriggers; 2 each 3,500lb 102?W Torflex 0degree axle with 5 stud hubs and drums with E/Z Lube, Wells Cargo weather resistant wiring package with 10? x2 ?? Electric Brakes; 4 each ST205/75R15 load range ?C? radial tire mounted on a 15?x6?, 5-bolt alumasport aluminum wheel (Capacity 1820 lbs); chassis fully undercoated with Corrosion Preventive Compound); 7?0? inside height, 78 ?? Vertical posts located on 16? centers; horizontal ?E? track (install full length on each sidewall and across front wall. Set top of track 30? off floor); single curbside door, aluminum RH hinge with flush lock ? opening 36?Wx75?H (start 26? off front exterior wall on curbside); 36?x36? pre-framed heavy duty lift up access door with keyed flush lock ? start 12? off front exterior wall on roadside. Door opening to be flush with the floor; 6 ?? x 6 ?? locking power cord hatch (this hatch will be an air supply line. Location must be discussed); A-frame mounted base and vented aluminum generator housing, locable; swing-down rear ramp door with spring assist and aluminum anti-rack cam bar lock. Opening 76 ??W x 75?H; 70 7/8? x 12 ??L Aluminum extruded ramp toe ? (2400lb capacity per two wheel vehicle); 22? x 15? radius tinted glass picture window (center in upper 1/3 rd of side door); custom width 1? mini blinds to cover 15? wide x 22? radius tinted window in side door; ?? exterior grade plywood floor, exterior surface undercoated, interior surface painted gray; heavy duty rubber ?lavent? floor covering full length of trailer (install on ramp door, as well); 5/8? plywood interior sidewall liner; ?? Lauan plywood interior sidewall liner; 1 5/8? fiberglass sidewall insulation, R5 value; 1 5/8? ceiling insulation; insulated both end caps and line end caps with aluminum cove, 18 each full width ceiling lined with white Kemlite covered ?? plywood contoured to roof radius (does not include lining end cap); 2 each 73?H x 48 ??W x 24?D, steel shelving unit with four, 48? wide adjustable shelves & 3? Bin fronts and end panels (capacity 250 lbs pre shelf) Install after discussions; aluminum covered bench seat with breathe air bottle compartments against wall (discuss with technical), build bench 31?D (over-all) 84?L x 22?H. Unit is to be built with aluminum 1? x 2? tubular frame, decked with ?? plywood. Round front edges/corners of bench. Cover plywood surface with mill finished aluminum laminate?be sure to not install screws on top surface on bench seat; 6 each, 16?H x 16?D overhead cabinet (install on front wall from curbside wall to steel shelving); 6 each, laminated permanent inside counter, 36?L x 20?D?Color ? Light grey (install on front wall starting at curbside wall. Counter height to be 30?) Undercounter supports to be 1? x 1? aluminum tubing, angled to front wall; Dive suit closet with full width hanging bar 72? off floor and 20? deep shelf above hanging bar (install at end of steel shelving on roadside. Build 30?W x 24?D x full height (equipment with maximum wide right hand hinged door with positive locks in upper and lower 1/3 rd of door; exterior cold water shower with removable hand held shower head pricing includes?25 gallon fresh water tank, 12 volt demand pump, recessed shower unit in sidewall, all plumbing and controls; 12 volt exterior surface mounted quartz/halogen light?center on rear roof cap toward roadside corner from center 3 light CLU set to shine on ramp door; 2 each, 3-way, 12 bolt wall switch (install 1 each at side entry door and 1 each on curbside rear cornerpost to control interior ceiling lights); Recessed battery box assembly. Consists of 100AMP hour deep cycle battery, vented battery box, 6 circuit fuse panel & 30AMP PC30 power source (install discuss with technical); 5 each 12 volt dome light with optic lens center, 3 each equally spaced in ceiling(install 1 each in suit closet and center 1 each over aluminum bench seat); 2 each 12 volt interior wall switch (install 1 each just inside dive suit closet. Install 1 each at rear corner next to aluminum bench); 2 each exterior 15 amp, 120 volt GFI duplex outlet (install 1 each per sidewall at rear of wheelbox, on lower extrusion); 2 each wall switch for 120 volt electric (install 1 each to control roadside and 1 each to control curbside recessed lights) install both at side door; wall switch for 120 volt electric (to control telescoping lights) Install at side door; wall switch for 120 volt electric (for interior ceiling lights?install at side door); 2 each exterior 120 volt, 500 watt telescoping removable quartz light (includes GFI outlet & mounting bracket) Install 1 each per corner on front wall. Set as high as possible and still be reachable from the ground by a 6ft tall person; 3 each 15 AMP, GRI 120 volt duplex wall receptacle; 50 AMP, 120v/240 volt 16 circuit service panel with at 50 AMP main breaker, 25ft shoreline, and locking cable hatch; 4 each 500 watt recessed quartz flood light (includes 120 volt receptacle) Install 1 each per corner on roadside, as high as possible. Install 1 each on curbside wall just behind side door and 1 each at rear curbside rear corner at same height; 2 each 4ft double fluorescent light fixture with diffuser cover (tubes not included) center equally spaced in ceiling; 120 volt, 13500 BTU roof mounted air conditioner with 56oo BTU heat strip (center in ceiling); 330 square feet .030 prefinished Indigo Blue smooth exterior aluminum installed vertically with non-corrosive mechanical fasteners; 2 each Wells Cargo flow-thru sidewall vent (install 1 each on roadside wall at front corner; install 1 each on curbside wall at rear cornerpost as low as possible); 24? high aluminum tread plate stone guard with wrapped integrated corners; pair of aluminum tread plate teardrop fenderettes; lighted exterior removable wet/dry magnetic message board 30?H x 36?L, includes 12 volt porch light with switch, centered over message center (exterior mounting brackets and interior mounting system for transport); 16ft A&E roll-up awning?Color to be determined (install on curbside wall); Wells Cargo L.E.D. safety package?consists of LED clearance lights in place of standard clearance lights. Clearance lights on rear roof cap used as high profile brake light and fender mounted clearance lights used as turn indicator; 2 each LED wraparound trail light with integrated side rear marker light; SAE color coded 12 volt electrical system, exterior lighting package; DOT ?A? frame mounted 22 AMP hour UI series battery, breakaway switch, aluminum mounting bracket, cover battery ?charge? indicator, and diode isolation. Battery acid included; seven way trailer end connector; spare tire & wheel ? st205/75R15 load range ?C? Radial tire on a 5 bolt alumasport aluminum wheel; deluxe 6500 watt electric start Honda generator w/battery?portable model ES6500, install on exterior A-frame; and, 6 each F track 12ft tie strap with weblock assembly. Order shall be FOB: Destination, Los Angeles, CA; Miami, FL; New York City, NY; and, Washington Field Office, Washington, DC. Items called for by this RFQ have been identified in the synopsis/solicitation by specific design and/or description. All quotes will be considered. If requested by the FBI, each offeror shall submit sample drawings of the item he/she proposes. The provision at FAR Clause 52.212-1, Instructions to Offerors (JAN 2004), and addendum is incorporated. ADDENDUM to 52.212-1, modify (b) Submission to offers: "Submit signed and dated offers to the attention of Ms. Theresa M. Powell, Contracting Officer, at via facsimile to (703) 632-1607.? All quotes are due by 2:00 PM, EDT, 09/13/2004. Delivery of items shall be 120 days after-receipt-of-order. Incorporated by reference are the FAR Clauses 52.212-4, Contract Terms and Conditions (DEC 2003), and 52.212-5, Contract Terms and Conditions Required to Implement Statutes and Executive Orders (OCT 2003), Subsection (a), (d), and (e). ADDENDUM to Clause 52.212-4, add 52.211-6-BRAND NAME OR EQUAL (AUG 1999); 52.233-2-SERVICE OF PROTEST (AUG 1996) and, 52.214-31-Facsimile Bids (DEC 1989). The Department of Justice (DOJ), Justice Acquisition Regulation Clauses, 2852.233-70-PROTESTS FILED DIRECTLY WITH THE DEPARTMENT OF JUSTICE (JAN 1998); 2852.201-70-CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE (COTR) (JAN 1985). Mr. Anthony Baumann, Chief Contracting Officer, Federal Bureau of Investigation, 935 Pennsylvania Ave., N.W., Washington, D.C. 20535-0001, shall serve as the FBI's contact in accordance with 52.233-3-Protest after award. ADDENDUM 52.212-2(a)--Award will be based on product, past performance and price. Past Performance and product when combined are significantly more important than cost or price. However, as quotes become more equal in their product merit, the evaluated cost or price becomes the determining factor. Past Performance will be based on telephonic performance evaluations received from previous contacts provided in the quote. Any vendor not having government or commercial experience will be rated as "Neutral." Offerors must acquaint themselves with the regulations concerning Commercial Item acquisition contained at FAR Subpart 12 and must ensure that all Representations and Certifications (located on the Internet) are executed and returned as required in this synopsis/solicitation. Website: (FAR) http://www.acqnet.gov.
- Place of Performance
- Address: FBI Academy, Quantico, VA
- Zip Code: 22135
- Country: USA
- Zip Code: 22135
- Record
- SN00659778-W 20040830/040828211649 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |