MODIFICATION
61 -- Temperature and Flow Gauge for Chief Joseph Dam, Bridgeport ,WA
- Notice Date
- 9/22/2004
- Notice Type
- Modification
- NAICS
- 423830
— Industrial Machinery and Equipment Merchant Wholesalers
- Contracting Office
- US Army Engineer District, Seattle, ATTN: CENWS-CT, PO Box 3755, Seattle, WA 98124-3755
- ZIP Code
- 98124-3755
- Solicitation Number
- W912DW-04-Q-0186
- Response Due
- 9/24/2004
- Archive Date
- 11/23/2004
- Small Business Set-Aside
- Total Small Business
- Description
- Requesting a Temperature and Flow Gauge for Chief Joseph Dam, Bridgeport ,WA. Go to the following address for all available project information: http://www.nws.usace.army.mil/ct/ebs/AdvertisedSolicitations.asp. Offerors are responsible for checking the referenced page for any update(s) to the solicitation. The website is occasionally inaccessible due to maintenance. The Government is not responsible for any loss of Internet connectivity or lack of access to the document posted at the referenced we bsite. The equipment required is Temperature and Flow Gauge for Chief Joseph Dam, Bridgeport, Washington. It is important for performance and consistency that the following specifications be required. This specification covers the supply of Temperature Ga uge to Chief Joseph Dam Project, Bridgeport, WA. Remote Reading Dial Thermometers 1. Gauge Type: a. ASME B40.4-2001 Class 4b filled system thermometer, Ashcroft or equal. b. Gauges as indicated in Table 2. 2. Gauge Description: a. Remote-mounted, aluminum hinged ring, 6 flush-mounted (ASME B40.4-2001 Fig5 b), rear connection. b. Bendable extension with union connection (see Table 2). c. Stainless steel spring armor. d. 0 - 120?C and 20 - 100?C (see Table 2). e. Double high electric contacts (normally open) with separate commons. f. No mercury shall be permitted. 3. Specifications: a. Thermometer shall comply with ASME B40.4-2001 Class 4b. b. Accuracy shall be +/- 1% of range span. c. Movement shall be damped (silicone or equal) for increased resistance to shock and vibration. d. Thermometer must be mountable in any configuration without needing correction for head or elevation error; thermometer bulb must require no special orientation. e. Pointer shall be field-adjustable. f. Dial shall no less than the recommended minimums of ASME B40.4-2001 / 7.2 thru 7.4. g. The thermometer dial shall be designed to prevent parallax (anti-parallax) reading errors and shall be a white face with black graduations. h. Thermometer case shall be aluminum or better with black epoxy finish and with a hinged ring permitting lens replacement and pointer adjustment. i. Window shall be in accordance with ASME B40.4-2001 / 7.5.2 thru 7.5.4 j. Gauge shall permit adjustment of zero and contact set points externally from the front of the gauge without removing the gauge from its mounting. k. Case depth shall not exceed 3 inches beyond mounting flange. l. Contact wires and capillary tube must exit rear of case. m. The extension to the bulb shall be: See Table 2. n. The capillary shall be: See Table 2. o. Capillary armor, probe and bendable extension material shall be AISI 300 series stainless steel. p. The electric contacts shall be double high (normally open) contacts configured to close upon temperature increase (with adjustable set points), switch ratings shall be no less than 120V AC, 1 amp (125VDC, 0.5 amp) resistive load max switching current. q. Electrical switch contacts shall be magnetic type snap-action contacts, high adjustable, electrically independent (separate commons) and ungrounded. Contact materials shall be silver palladium (AgPd 80/20) or better (gold). Table 2 - Temperature Gauge: Units/Gauge Quantity Dial Range (?C) Capillary Length Bushing/Bendable Extension/Probe Length 1 Thru 16 Air Cooler 97 0 - 120 100 ft. ? MPT Bushing / 15 / 5/8x6 1 thru 16 Thrust Bearing 17 20 - 100 80 ft. ? MPT Bushing / 39.5 / 5/8x6 1 thru 16 Thrust/Guide Bearing Oil 17 20 - 100 90 ft. ? MPT Bushing / 19 / 5/8x6 1 thru 16 Gen Guide Bearing 17 20 - 100 90 ft. ? MPT Bushing / 9 / 5/8x6 1-4 & 15-16 Turbine Bearing & Oil 13 20 - 100 70 ft. ? MPT Bushing / 3 / 5/8x5 5 thru 14 Turbine Bearing 11 20 - 100 75 ft. ? MPT Bushing / 24 / 5/8x6 5 thru 14 Turbine Bearing Oil 1 20 - 100 75 ft. ? MPT Bushing / 3 / 5/8x6 Specifications Pressure Differential Gauges Units 1 thru 16 Scope This specification covers the sup ply of pressure differential gauges to Chief Joseph Dam Project, Bridgeport, WA. Low-Pressure GPM Indicating Differential Pressure Gauge/Switch 1. Gauge Type: a. 6 dial differential pressure gauge, Ashcroft or equal. b. H2O ranges see Table 1. c. With false reading dial of 0 to xxx GPM see Table 1. d. Range and quantity as indicated in Table 1. 2. Gauge Description: a. 6 dial. b. Low-pressure differential, GPM indicating. c. Stainless steel diaphragm and housing and socket material. d. 1/4 NPTF lower connection. e. Wall mounting bracket. f. Electric warning contacts, N.O./N.C., with separate commons. g. No mercury shall be permitted. 3. Specifications: a. Gauge shall be +/- 2.5% full-scale accuracy or better, 6 diameter stainless steel case (IP54 rating) with diaphragm made from high strength cobalt alloy (Duratherm 600 = NiCrCo alloy) or equal and AISI 300 series stainless steel movement. b. Gauge shall permit adjustment of zero and contact set points externally from the front of the gauge without removing the gauge from its mounting. c. Case shall include a wall-mounting bracket. d. Dial shall be a false-reading, white face with black indicators with dial indicating specified GPM (Gallons per minute) see Table 1. e. Dial shall at least meet the recommended minimums of ASME B40.4-2001 / 7.2 thru 7.4. f. The dial shall be designed to prevent parallax (anti-parallax) reading errors. g. Gauge shall be capable of withstanding a minimum static pressure of 145 psi without sustaining damage. h. The electric contacts shall have adjustable set points and switch ratings shall be no less than 125V AC, 1 amp (125VDC, .5) amp resistive load max switching current. i. Electrical switch contacts shall be magnetic type snap-action contacts, electrically independent (separate commons) and ungrounded. j. Contact materials shall be silver palladium (AgPd 80/20) or better (gold). k. Contact wires must exit rear of case. l. One normally open (N.O.) and one normally closed (N.C.) contact at zero differential. m. Contacts shall change state at the preset values as the pointer increments clockwise. n. Contact materials shall be silver palladium (AgPd 80/20) or better (gold). o. Electrical switch ratings shall be no less than 125V AC, 1 amp (125VDC, .5 amp) resistive load max switching current. Table 1 - Low-Pressure GPM Differential Pressure Gauge/Switch: Quantity Dial Range (GPM) Inches H2O Range Ea.17 0 60 100Ea.17 0 1600 300 The specifications will be available with the solicitation. The North American Industry Classification System (NAICS) Code is 334513, which is matched to SIC code 6680. Additional contracting opportunities, visit the Army Single Face to Industry at http: //acquisition.army.mil/. This solicitation will be issued as an Electronic Bid Set (EBS) on the Seattle District U.S. Army Corps of Engineers Web page in electronic format only. No disks will be mailed. Firms must register via the Internet at the followi ng address: http://www.nws.usace.army.mil/ct/ in order to receive notification of solicitation/amendment posting. The solicitation will be available for download on or about 22 September 2004.
- Place of Performance
- Address: US Army Engineer District, Seattle ATTN: CENWS-CT, PO Box 3755 Seattle WA
- Zip Code: 98124-3755
- Country: US
- Zip Code: 98124-3755
- Record
- SN00679662-W 20040924/040922212439 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)