SOLICITATION NOTICE
20 -- Fabrication of Five Grid Coolers for Vessel Hayward
- Notice Date
- 4/22/2005
- Notice Type
- Solicitation Notice
- NAICS
- 332999
— All Other Miscellaneous Fabricated Metal Product Manufacturing
- Contracting Office
- US Army Engineer District, New York, CENAN-CT, 26 Federal Plaza, New York, NY 10278-0090
- ZIP Code
- 10278-0090
- Solicitation Number
- W912DS-05-T-0016
- Response Due
- 5/4/2005
- Archive Date
- 7/3/2005
- Point of Contact
- gregory.g.cuyjet, 917-790-8172
- E-Mail Address
-
US Army Engineer District, New York
(gregory.g.cuyjet@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. 1 Solicitation number W912DS-05-T-0016 is issued as a Request for Quotation. The U. S. Army Corps of Engineers, New York District is issuing this combined synopsis/solicitation to award a commercial contract for furnishing all labor, materials,equipment, tools, and services for the Propeller Fabrication for the Vessel Hayward. This action was previously synopsized as set-aside for small business. No quotes were received. This action is now unrestricted. Brand Name or Equal specifications stated herein are a firm requirement. All responsible sources may submit a proposal, which shall be considered. For EDI transfer, this solicitation is issued as a request fo r quotation. The NAICS code and small business size standard are 332999 and $6 million average annual receipts over the past three years. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-02, effective March 23, 2005 . Delivery is F.O. B. destination to Caven Point, Jersey City, NJ 07305. Clauses applicable to this solicitation and incorporated by reference are FAR 52.212-2, Evaluation of Commercial Items (JAN 1999) and the significant evaluation factors are (i) techni cal capability of the item offered to meet the Government requirement and (ii) price. Award will be made to the lowest price, technically acceptable proposal. FAR 52.212-3, Offeror Representations and Certification Commercial Items (MAR 2005) is applicab le and a completed copy will be required prior to award. An offeror shall complete only paragraph (j) of this provision if the offeror has completed the annual representations and certifications electronically at http://orca.bpn.gov. FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items and FAR 52.225-1, Buy American Act-Supplies, and FAR 52.211-6, Brand Name or Equal (AUG 1999) are applicable. QUOTES SHALL BE ACCEPTED BY FAX AT 212-264-3013, ATTENTI ON GREGORY CUYJET, PROCUREMENT ANALYST. The project manager is Ronald Rhea at phone number 212-264-0170. Mailed in quotes shall be delivery to the U.S. Army Corps of Engineers, New York District, Contracting Division, Room 1843, 26 Federal Plaza, New York, NY 10278-0090. QUOTES SHALL INCLUDE DESCRIPTIONS, SPECIFICATIONS, PRICES, TIME OF DELIVERY,DISCOUNT(S) IF ANY, CAGE CODES AND TAX ID. THE TIME AND DATE FOR THE RECEIPT OF QUOTES IS EXTENDED TO MAY 4, 2005 AT 4:00 PM EASTERN DAYLIGHT TIME. HTTP://NANEBS.NAN.USACE.ARMY.MIL. This website is the official medium through which you as a contractor shall be notified of the availability of, and of amendments to, solic itations. To be officially notified of any updates for solicitations listed on this website, you must register separately for each solicitation of choice. By registering, you are providing an email address through which the government can communicate updat es. During the registration process, however, you have the option of concealing your registration from other parties (including the government); nonetheless, regardless of whether you register openly or conceal your registration, as a registered party you will receive all emailed updates. However, by openly registering, interested parties can identify you as someone with whom they may wish to do business for subcontracting purposes. However, should there be a circumstance in which parties cannot be reached via website notification, it will only be to the openly registered parties that the government will owe a responsibility for ensuring that updates are provided. But you are not required to register in any for m, in order to download a solicita tion or its amendments. Downloading any solicitation and any amendment from this website is free. Section C: Description/Specification/Statement of Work Specifications for Fabrication of Hayward Grid Coolers I. GENERAL The contractor shall quote a price for fabrication of all five (5) grid coolers below. The keel coolers should be similar or equal to the Fernstrum grid coolers described in paragraph 2 below. The price quoted to include delivery to Caven Point, Jersey City 07305. II. TECHNICAL SPECIFICATIONS 1. Provide two (2) copper-nickel grid cooler for the vessel Hayward similar or equal to Fernstrum model DX1690F-S2. The grid coolers must fit the existing hull openings. Price quote: ___________________________________. The dimensions are as follows: Pipe diameter inlet: 4 inches Pipe diameter outlet: 4 inches Overall length: 97-1/4 inches Overall width: 14-9/16 inches Distance from center of outlet to center of inlet: 90 inches Minimum heat transfer: 34,125 BTUs Fresh water temperature in grid cooler: 170 degrees F 8 bolt (equally spaced) flange connection at inlet and outlet Intermediate connections: 1 (at 45 inches from center of inlet) 2. Provide two (2) copper-nickel grid cooler for the vessel Hayward similar or equal to Fernstrum model B884BF. The grid coolers must fit the existing hull openings. Price quote: _______________________________. The dimensions are as follows: Pipe diameter inlet: 1.9 inches Pipe diameter outlet: 1.9 inches Overall length: 97-1/4 inches Overall width: 5-3/8 inches Distance from center of outlet to center of inlet: 84 inches Minimum heat transfer: 3,100 BTUs Fresh water temperature in grid cooler: 170 degrees F 4 bolt (equally spaced) flange connection at inlet and outlet Intermediate connections: 2 (starting at 28 inches from center of inlet) 3 3. Provide one (1) copper-nickel grid cooler for the vessel Hayward similar or equal to Fernstrum model D896F. The grid cooler must fit the existing hull openings. Price quote: ________________________. The dimensions are as follows: Pipe diameter inlet: 2-7/8 inches Pipe diameter outlet: 2-7/8 inches Overall length: 97-1/4 inches Overall width: 7-1/16 inches Distance from center of outlet to center of inlet: 96 inches Minimum heat transfer: 4,810 BTUs Fresh water temperature in grid cooler: 170 degrees F 4 bolt (equally spaced) flange connection at inlet and outlet Intermediate connections: 2 (starting at 32 inches from center of inlet) 4. Additional equipment required for installation of keel coolers: a. Five (5) isolator kits needed to protect hull against corrosion due to electrolysis. Price quote: _______________. III. FABRICATION DETAILS 1.The contractor shall fabricate five keel coolers: two (2) for the main engines, two (2) for the generators, and one (1) for the crane engine as follows: a. To obtain a proper bond, each piece of the keel cooler assembly shall be degreased and sandblasted before assembly. b. Each unit shall be soaked and flushed out at high temperatures during each interval of manufacture. c. After being soaked and flushed, each unit shall be inspected by running it through a separate underwater air test assure the integrity of braised or welded joints. d. Clean-up shall be done by sandblasting in a specially constructed 40' long, semiautomatic blasting cabinet. e. Ultra-sonic testing shall be used to check the brazed joints of each unit to assure that keel coolers are of adequate strength. f. In all respects, the each unit must be square and true. NOTE: THIS NOTICE WAS NOT POSTED TO WWW.FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (22-APR-2005); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.eps.gov/spg/USA/COE/DACA51/W912DS-05-T-0016/listing.html)
- Place of Performance
- Address: US Army Engineer District, New York CENAN-CT, 26 Federal Plaza, New York NY
- Zip Code: 10278-0090
- Country: US
- Zip Code: 10278-0090
- Record
- SN00794470-F 20050424/050422213338 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)