SOLICITATION NOTICE
99 -- Turnstile Maintenance
- Notice Date
- 11/14/2005
- Notice Type
- Solicitation Notice
- NAICS
- 811310
— Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Contracting Office
- Department of the Air Force, Air Mobility Command, 6th Contracting Squadron, 2606 Brown Pelican Ave., MacDill AFB, FL, 33621-5000
- ZIP Code
- 33621-5000
- Solicitation Number
- F2VUSM5266A200Z
- Response Due
- 11/17/2005
- Archive Date
- 12/2/2005
- Small Business Set-Aside
- Total Small Business
- Description
- STATEMENT OF WORK: Maintenance for Security all Turnstiles in SOCOM 1. General Description 1.1. The contractor shall provide all labor, materials, parts, equipment, tools, transportation, personnel, and all other items and services necessary to provide full maintenance for all turnstiles in SOCOM, in accordance with the terms of contract. 2.1. The contractor shall submit a written statement of work (SOW) to the government Point of Contact (POC) that includes pricing for any work which must be performed beyond this maintenance agreement. 2. General Requirements 2.1. All services shall be performed by the contractor at the on-site location of the equipment and with the best commercial practices established by the equipment manufacturer. All parts and material used to perform under this contract shall be new and from the same or better capacity and efficiency standards of the original manufacturers part. 2.2. Maintenance performed shall include manufactures recommended intervals and parts (attached) for three (3) dual (set includes separate entrance and exit) and one (1) single (used as a entrance/exit) Tomsed Security Turnstile, series 31 and 32 Security Turnstiles, (WWW.tomsed.com) and a set of Designed Security Inc (DSI), model ES810/ES840 Optical Turnstiles. 3. Cleaning up 3.1. The contractor shall dispose of all waste and scrap materials accumulated during the performance of this contract at no additional cost to the United States Government, and in accordance with all applicable laws. 3.2. The contractor is responsible for the correct removal and disposal of material and trash generated during the service. The dumpster on base CAN NOT be used by the contractor. All working areas shall be kept clean and tidy daily and until project completion. 4. Storage The contractor may store materials, tools, or equipment in the work area at his own responsibility. The United States Government is not responsible for larceny, etc. of this equipment. 5. Security procedures The contractor shall take care that all security and fire regulations are followed. 6. Welding If welding, cutting, or grinding is need to be accomplished for repair work. The contractor needs a WELDING (grinding, because of the sparks) permit. The contractor needs to contact the Base fire department for this permission. 7. Utilities The U.S. Government provides the electricity and water during the performance of the service available. The contractor is responsible for all connections. 8. Working Conditions The contractor may utilize the rest room within the SOCOM facility, provided he is escorted by a cleared SOCOM representative. 9. Special Requirements A list shall be provided of all individuals working under this contract before commencement of work in order to clear them to perform work on MacDill, AFB. 10. Replacement Parts All parts required during the individual maintenance service shall be included in the offer for the individual task. 11. Hours of operation Contractor will be given access to the facility within the time frame set forth by the contractor?s schedule. Coordination with the designated POC for unscheduled repairs/installation is required. 12. Point of contact Rafael Pacheco, Jr. Ph. 828-8296 Scheduled Maintenance Service for Security Turnstiles Service & Month Interval 1. Turnstile Foundation Cleaning: 1MO 2. Solenoid Assembly Inspection: 3MO 3. Self-Centering Plunger Lubrication: 3MO 4. Indicator Light Inspection: 3MO 5. Panel Cleaning: 3MO 6. Ratchet Assembly Inspection: 6MO 7. Plunger Roller Inspection: 6MO 8. Pivot Arm Lubrication: 12MO 9. Pivot Arm Inspection: 12MO 10. Locking Assembly Lubrication: 12 MO 11. Locking Bar Assembly Inspection: 12MO 12. Self-Centering Spring Adjustment: 12MO 13. Self-Centering Shock Absorber Adjustment: 12MO 14. Self-Centering Speed Control Spring Inspection: 12MO 15. Limit/Rotation Switch Inspection and Adjustment: 12MO 16. Controller Adjustment: 12MO 17. Electrical Wiring Inspection: 12MO 18. Fastener Inspection: 12MO 19. Turnstile Stability Inspection: 12MO 20. Spindle Arm Inspection: 12MO 21. Panel Inspection: 12MO 22. Bottom Spindle Bearing Lubrication: 12MO 23. Pivot Arm Spring Replacement: 12MO Notes: 1. A complete inspection should be performed on the turnstile after one full month of service. 2. If necessary lubrication of the bushings is to be done with a silicone or Teflon based spray lubricant. 3. A general purpose lithium based grease is to be used to lubricate the lower spindle bearing. Recommended Spare Parts 21-113 Limit/Rotation Switch 85-225 Solenoid 51-215 PLC Control Unit 85-270 Upper Flange Bearing 53-523 Bridge Rectifier 85-285 Self-Centering Mechanism Spring 53-791 Transformer 85-143 Lower Flange Bearing 85-156 Speed Control Cylinder 85-213 Solenoid Plunger Return Spring 85-214 Pivot Arm Spring 85-215 Linkage Pin To Pivot Arm WAGE DETERMINATION NO: 94-2125 REV (22) AREA: FL, TAMPA HEALTH AND WELFARE LEVEL ? INSURANCE ONLY **OTHER WELFARE LEVEL WD:94-2126
- Place of Performance
- Address: HQ USSOCOM/SOCS-PM-SM, 7701 TAMPA POINT BLVD, TAMPA, FL 33621
- Zip Code: 33621
- Country: US
- Zip Code: 33621
- Record
- SN00931654-W 20051116/051114211935 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)