Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JANUARY 13, 2007 FBO #1874
MODIFICATION

22 -- Railway Spanners

Notice Date
1/11/2007
 
Notice Type
Modification
 
NAICS
332999 — All Other Miscellaneous Fabricated Metal Product Manufacturing
 
Contracting Office
Surface Deployment and Distribution Command - W81GYE, ATTN: SDAQ, 200 Stovall Street, Alexandra, VA 22332-5000
 
ZIP Code
22332-5000
 
Solicitation Number
W81GYE-07-T-0016
 
Response Due
1/18/2007
 
Archive Date
3/19/2007
 
Small Business Set-Aside
Total Small Business
 
Description
This amendment is issued to respond to contractor's questions as follows: 1.(Q.) PLEASE CLARIFY..P.E. CERTIFIED, ENGINEERED AND TESTED. WE WOULD BE MAKING PER YOUR DRAWING. ASSUME THIS WAS PREVIOUSLY DONE. (A.) Professional Engineer certified and tes ted. Spanners should be load tested and accompanied by some type of certification which includes test date and certifier. Load test should be at least 20,000 lb capacity. 2.(Q.) KICK ANGES SHOWN CENTERED ON END VIEW AND ALSO SHOWN OFFSET ON ISO VIEW. WHI CH? (A.)Kick plate is a 90 degrees angle plate and is attached on the bottom, 12 from the end of the spanner. 3.(Q.)WHAT IS SPANNER OVERALL HEIGHT. 3-3/8 inches? (A.)The overall height of 3-3/8 inches to 4 inches is acceptable but spanners shall be n o higher than 4 inches. 4. (Q.)RE; ALUMINUM SIX FOOT SPANNERS. TRYING TO FIGURE OUT DRAWING. WOULD YOU HAVE DIGITAL PICTURE OR LOCATION WE COULD SEE ONE. OR OBTAIN SAMPLE UNIT FOR EVALUATION. (A.)Pictures of the spanners are located on the SDDC at website at www.sddc.army.mil. Follow the directions for accessing TEA Specs stated in the solicitation. 5.(Q.) WE ARE ORCA REGISTERED, DO WE STILL NEED TO SUPPLY A COPY OF COMPLETED 52.212-3? (A.)Yes, but only as required in the reference clause. 6.(Q.)SOLICITATION SAYS...SPANNERS SHALL MEET THE FOLLOWING SPECIFICATIONS: ALL ALUMINUM CONSTRUCTION; 20,000 LB SAFE WORKING LOAD (SWL) CAPACITY EACH; 2:L SAFETY FACTOR, P.E. CERTIFIED, ENGINEERED AND TESTED. WHAT ARE YOU LOOKING FOR, OR TESTED? (A.)See Question 1. 7.(Q.)FOR THIS PROJECT IS THERE A NSN NUMBER OR A PREFERRED VENDOR? (A.) No 8.(Q.)IS THIS TRULY SET FOR SMALL BUSINESS OR CAN WE BID ON THIS PROJECT? (A.)This procurement is 100% Small Business Set Aside. The closing date of 10:00 am 18 Jan 07 remains unchanged. All other terms and conditions remain unchanged.
 
Place of Performance
Address: Surface Deployment and Distribution Command - W81GYE ATTN: SDAQ, 200 Stovall Street Alexandra VA
Zip Code: 22332-5000
Country: US
 
Record
SN01209689-W 20070113/070111221202 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |