59 -- PURCHASE OF ABB DIGITAL RELAYS

Notice Date
2/6/2007
 
Notice Type
Solicitation Notice
 
NAICS
335314 — Relay and Industrial Control Manufacturing
 
Contracting Office
US Army Engineer District, Vicksburg, ATTN: CEMVK-CT, 4155 Clay Street, Vicksburg, MS 39183-3435
 
ZIP Code
39183-3435
 
Solicitation Number
W807PM63561783
 
Response Due
2/12/2007
 
Archive Date
4/13/2007
 
Small Business Set-Aside
N/A
 
Description
USACE, Vicksburg Consolidated Contracting Office proposes to issue a sole source award to ABB, Inc., 7036 Snowdrift RD STE 2, Allentown, PA, 18106-9274. The purpose of the award is for the vendor to provide the Blakely Power Plant protective relay sy stem with ABB digital relays. These solid state relays are not compatible with any other manufacturer due to software or wiring configuration, the entire protective system at Blakely is based on these relays, software and settings. The use of any other rel ay besides the ones described below would require additional engineering and construction costs. The following are the required standards for the relays: GPU 2000R Generator Protection Relay, Configuration: Standard w/ Differential& Impedance, Current Range: 2.0-8.0A Phase, 0.4-1.6A Ground, Frequency: 60 Hz, Control Voltage: 70-280 VDC, HMI: Yes, for Horizontal Mounting, Rear Comm. Port: RS-232 & RS-485, bo th isolated, Communication Protocol: ModBus, Oscillography: Yes, Programmable Curves: No, Load Profile: No, Style No.: 589W1412-61004; TPU 2000R Transformer Protection Relay, Configuration: 3-Windings, Current Range: 1.0-12.0A, Phase & Ground, Frequency: 60 Hz, Control Voltage: 70-280 VDC, HMI: Yes, for Horizontal Mounting, Rear Comm. Port: RS-232 & RS-485, both isolated, Communication Pr otocol: ModBus, Oscillography: Yes, Programmable Curves: No, Load Profile: No, Style No.: 588TC412-61004; DPU 2000R Feeder Protection Relay, Configuration: Standard, Current Range: 0.4-12.0A, Phase & Ground, Frequency: 60 Hz, Control Voltage: 70-280 VDC, HMI: Yes, for Horizontal Mounting, Rear Comm. Port: RS-232 & RS-485, both isolated, Communication Protocol: ModBus, Oscillography: Yes, Programmable Curves: No, Load Profile: No, Style No.: 587R0412-61004; REL 512 Distance Relay, Rated Current: 5A, Frequency: 60 Hz, Control Voltage: 110/125 VDC, Breaker Failure: Yes, Multi-Shot Reclosing: Yes, w/Volt/Sync Check, Communication Protocol: ModBus Plus, Style No.: R512H6B1B3MN1N; REF 610 Feeder Protection Relay, Rated Current: 5A, Phase & Ground, Control Voltage: 100-240 VDC, 110-250 VDC, I/O Extension Module: No, Communication Module: RS-485 (Modbus, SPA, IEC-103), Style No.: REF610B55HCNR; SEL 587Z High Impedance Differential Relay, Power Supply: 48/125 VDC or 125 VAC, Control Input Voltage: 125 VDC, Energy-Clamping MOVs: High Energy (2 MOVs), Rated Current: 5A, Mounting: Horizontal Rack Mount, Communication Ports: RS-232 Front, RS-485 Rear, Communication Protocol: ModBus RTU, Cat. No.: SEL-0587Z0X325H22XX. A firm-fixed price award will be made utilizing the Simplified Acquisition Procedures. Any other responsible source able to provide the supplies is encouraged to respond to this announcement within 7 days after its publication. This is not a request for q uotations and there is no solicitation available at this time.
 
Place of Performance
Address: US Army Engineer District, Vicksburg ATTN: CEMVK-CT, 4155 Clay Street Vicksburg MS
Zip Code: 39183-3435
Country: US
 
Record
SN01226776-W 20070208/070206221059 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.