Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 07, 2007 FBO #1927
SOURCES SOUGHT

61 -- Power Generation and Management

Notice Date
3/5/2007
 
Notice Type
Sources Sought
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
1940 Allbrook Drive Suite 3 Wright-Patterson AFB, OH
 
ZIP Code
00000
 
Solicitation Number
BRITESII
 
Response Due
3/27/2007
 
Archive Date
5/25/2007
 
Small Business Set-Aside
N/A
 
Description
1. The Aeronautical Systems Center (ASC) is soliciting information to identify possible sources to provide components for lightweight power generation and management. This Request for Information (RFI) is issued for informational purposes only and does not constitute a solicitation or commit the government to award a contract now or in the future. Submitting information for this RFI is voluntary, and participants will not be compensated. 2. Respondents to this RFI should describe their ability to meet and/or exceed the following objectives: BATTERY: a. Battery should provide electrical power simultaneously to the PRC-117 radio, laser target designator (SOFLAM), Multi-Band Inter-Team Radio (MBITR), and CF-18 (or CF-19) Toughbook (laptop) computer. b. Batteries offered should power all devices listed in 2a (400 W of power) c. Batteries should weigh approx 1.9 kilograms or less; d. Total energy capacity of the battery must be approx 250 Watt hours or greater. e. Batteries should have between 8 to 10 Amp hours of capacity in the form of a rechargeable battery. f. Batteries must have certification testing completed to allow for shipment by commercial air transportation. g. Batteries should be capable of providing power in an operating environment with external temperatures from -20C to 55C. An internal heater would be desirable. POWER MANAGER h. Power manager should weigh approx 400 grams or less. i. Power manager should provide for a state-of-charge indication for the rechargeable batteries using SM-BUS protocol. j. Power manager should be able to route power to both 30V devices, as well as have an adjustable range for devices ranging from 10 ? 20 V. k. Power manager should provide information via a USB protocol. Software for PC should be included with the power manager. l. Power manager should provide peak power tracking capability for solar panels. m. Power manager should have a volume of less than 25 cubic inches. n. Power manager should be interoperable with current BRITES Spiral I cables and batteries. o. Power manager should archive data to fully document all activity for a minimum of 72 hours. MISCELLANEOUS p. Appropriate cabling for connections to/between components and the systems listed in 2a must be provided. q. The respondent must be capable of demonstrating the offered product within 30 days in a tactical, field-ready configuration suitable for use in combat. r. The product offered should be representative of the proposed production item. s. The product must be non developmental to field. t. The offeror must demonstrate ability to rapidly manufacturer/deliver systems in large quantities. 3. It is desirable, but not required that responses be submitted on CD-ROM in an electronic format that is compatible with Microsoft Windows/Office with no macros. Two (2) copies of the CD submittals should be submitted as set forth in paragraph 4. If the CD contains proprietary/competition sensitive material, the CD and cover label should be marked ?Proprietary/Competition Sensitive Information?. Two paper copies should be submitted as set forth in paragraph 4. Paper copies must be clearly labeled ?Proprietary/Competition Sensitive Information? on the cover sheets and, in close proximity to this type of information, on each applicable page. Proprietary/Competition sensitive information will be protected from disclosure. E-mail copies of the paper submittal will be accepted. 4. Responses must be received no later than 27 March 2007. Both copies of the CD and paper (e-mail) submittals should be sent to 670 AESS/PK, Attn: George Walter, (Com: 937-255-9351, e-mail: George.Walter@wpafb.af.mil), or Nancy Leggett, (Com: 937-255-1696, e-mail: Nancy.Leggett@wpafb.af.mil), Bldg 46, 1895 Fifth Street, WPAFB OH 45433-7200. Any technical questions should be directed to Capt Natasha Hinkson, (Com: 937-255-3402, e-mail: Natasha.Hinkson@wpafb.af.mil). For more information on "Power Generation and Management", please refer to: https://www.pixs.wpafb.af.mil/pixs_solicitation.asp?id=5158
 
Web Link
Power Generation and Management
(https://www.pixs.wpafb.af.mil/pixs_solicitation.asp?id=5158)
 
Record
SN01243776-W 20070307/070305220456 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers