MODIFICATION

Y -- REQUEST FOR INFORMATION (QUESTIONS AND ANSWERS) NO.1, LOBBY RENOVATION, BUILDING 230, SOL: W912CH-07-R-A505

Notice Date
4/19/2007
 
Notice Type
Modification
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
TACOM - Warren Acquisition Center, ATTN: AMSTA-AQ-AMB, E Eleven Mile Road, Warren, MI 48397-5000
 
ZIP Code
48397-5000
 
Solicitation Number
W912CH-07-R-A505
 
Response Due
5/3/2007
 
Archive Date
7/2/2007
 
Small Business Set-Aside
N/A
 
Description
REQUEST FOR INFORMATION, NO: 1, LOBBY RENOVATION, BUILDING 230 SOL: W912CH-07-R-A505 1) Hallway Doors  What size glass is required, and should this be laminated? Glass shall be fire rated. It doesn't have to be laminated. Match the size of existing doors. 2) Is it possible to get a better detail or picture of the etchings? Yes. A clear picture can be seen at the TACOM-LCMC Business page: http://contracting.tacom.army.mil/opportunity.htm View under Service Contracting, Construction/Base Ops Team 3)Print asks to replace the sidelight windows in the vestibule, are you referring to the windows in the returns as well? The exterior vestibule doors require a blast resistant door system with doors that swing out. At a minimum, the doors and the windows to each side shall be replaced. If the window above the exterior vestibule doors needs to be replaced to achieve the blast rating, the contractor shall replace that as well. The contractor will have to provide a submittal for approval showing it meets th e blast resistant standard. Note: These doors will also be on a automatic opening system. Then interior vestibule doors, the doors and the windows to each side shall be replaced 4) Vestibule  Do any of the interior walls / doors of the vestibule need to be blast resistant? Only exterior vesitbule doors and windows that are rquired to be replaced have to be blast resistant. 5)Exterior windows  do these need to be blast resistant? Exterior windows need to be laminate glass. 6)Hallway doors  Are these to be wood or metal? Hallway doors, shall be full glass with narrow metal stiles on top and bottom. 7) Lobby Ceiling  The 24 in x24 in Sonex Contour has various types and thicknesses. Do you have a model number that we can reference? SCTB1 BASIX with backer 1 5/8 in thick or equal. 8) Vestibule Ceiling  Do you have any contact information for Global Specialty Products? This is their link. www.surfacingsolution.com
 
Place of Performance
Address: TACOM - Warren Acquisition Center ATTN: AMSTA-AQ-ASRB, E Eleven Mile Road Warren MI
Zip Code: 48397-5000
Country: US
 
Record
SN01277102-W 20070421/070419221201 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.