Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 27, 2007 FBO #2039
SOLICITATION NOTICE

58 -- Various Power Amplifier Systems for the Electronic Proving Ground (EPG), Fort Huachuca, Arizona 85613

Notice Date
6/25/2007
 
Notice Type
Solicitation Notice
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
ACA, White Sands Missile Range, Directorate of Contracting, Bldg 143, 2nd Floor, Crozier Street, White Sands Missile Range, NM 88002-5201
 
ZIP Code
88002-5201
 
Solicitation Number
W9124Q-07-R-EPGHPA
 
Response Due
7/2/2007
 
Archive Date
8/31/2007
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The Electronic Proving Ground, Fort Huachuca, Arizona is soliciting proposals for the following requirement: 10.0  100 MHz High Power Amplifier: 1 each, broadband linear High Power RF Amplifier (HPA) system that is rated at of 1000 watts (minimum) with minimum frequency coverage of 10 to 100 MHz. Technical requirements: The Linear HPA will be a small, self-contained, lightweight, air-cooled, broadband amplifier that provides instantan eous broadband signal generation to develop RF fields in an open field test site. The amplifier must be of rugged solid-state and Class AB linear design. The amplifier will be housed in a single equipment rack and will provide a complete stand-alone perf ormance for testing. HPA will be of a design that provides a high efficiency operation rate, proven reliability, low distortion and is stable across the frequency range. The HPA must provide high gain, wide dynamic range, low distortions and good linearit y. Input signals will be from signal generators that are both swept and stepped through the frequency band. The amplifier will be able to be controlled either locally or by remote. The amplifier's front panel must have a LCD Touchscreen digital displa y that provides extensive system status information accessed through a series of menus via soft keys. Status indicators include power on, warm-up, standby, operate, faults, excess reflected power warning and remote standby mode, VSWR protection, gain contr ol, ALC on/off, forward and reflected RF output sample port, plus monitoring of the HPA amplifier critical parameters. Front panel type-N connectors are required. The amplifier will have installed front handles. The amplifier must have thermal overload, over current and over voltage circuit protection. The HPA must also have an Ethernet Interface. REQUIRED SPECIFICATIONS: Minimum 2/year warranty; Must include a comlete set of operator/system technical manuals; System must be delivered within 120 day s of purchase; Frequency Range.10-100 MHz; Output Power CW1000 Watts typical; Power Output @ 1 dB G.C.P 750 Watts min; Power Gain @ 1 db G.C.P 60 dB min; Small Signal Gain Flatness .+ 1.5 dB; 3rd Order Intercept Point&+64 dBm; Input/Output VSWR -10 dB; Harmonics @P1dB G.C.P.-20dBc; Gain&60dB; Gain Adjustment Range&25dB typical; Input power for Rated Output&0 dBm typical; Noise Figure @ max Gain.10 dB typical; VSWR&.@ P1dB G.C.P Infinite @ any angle & magnitude (nominal) Spurious Signals -60dBc max; Op erating Voltage 180 min/2600 max Volts Single Phase 50-60Hz; AC Power Consumption @ 1000W...3500 Watts; RF Input.+10 dBm max RF Input Signal Format .CW/AM/FM/PM/Pulse/Digital; Input/Output Impedance&50 Ohm Class of Operation&.A/AB; Input Overdrive&..+ 6dBm max; Dimensions =/ greater than 19inx8.75inx22in; Weight&=/greater than 80 lb max; RF Connectors Type N Female Grounding Chassis; Cooling...Internal Forced Air; Operating Temperature...0o min/+50o max C; Non-Operating Temperature..-40 min/+85 max C ; Operating Humidity..95% min Non-Condensing; Operating Altitude&10,000ft min/30,000 max ASL; Shock and Vibration&Normal Truck or Trailer; Thermal Overload&85o C shutdown. 100  500 MHz High Power Amplifier requirements: 1 each, broadband linear High Pow er RF Amplifier (HPA) system that is rated at of 1000 watts (minimum) with minimum frequency coverage of 100 to 500 MHz. Technical requirements: The Linear HPA will be a small, self-contained, lightweight, air-cooled, broadband amplifier that provides in stantaneous broadband signal generation to develop RF fields in an open field test site. The amplifier must be of rugged solid-state linear design. The amplif ier will be housed in a single equipment rack and will provide a complete stand-alone performance for testing. HPA will be of a design that provides a high efficiency operation rate, proven reliability, low distortion and is stable across the frequency ran ge. The HPA must provide high gain, wide dynamic range, low distortions and good linearity. Input signals will be from signal generators that are both swept and stepped through the frequency band. The amplifier will be able to be controlled either loc ally or by remote. The amplifier's front panel must have a LCD Touchscreen digital display that provides extensive system status information accessed through a series of menus via soft keys. Status indicators include power on, warm-up, standby, operate, f aults, excess reflected power warning and remote standby mode, VSWR protection, gain control, ALC on/off, forward and reflected RF output sample port, plus monitoring of the HPA amplifier critical parameters. Front panel type-N connectors are required. T he amplifier will have installed front handles. The amplifier must have thermal overload, over current and over voltage circuit protection. The HPA must also have an Ethernet Interface. REQUIRED SPECIFICATIONS: Minimum 2/year warranty; Must include a complete set of operator/system technical manuals; System must be delivered within 120 days of purchase; Frequency Range...100-500 MHz; Output Power CW&..1100 min/1200 typical Watts; Power Output @ 1 dB G.C.P 1000 Watts min Power Gain @ 1 db G.C.P. .60 dB min; Input Power for rated output power.1.0 mW; Gain Flatness/Leveled ALC..+ 2.0/+0.5 dB; Gain Adjustment..25 min/30 max dB; Input VSWR&.2:1; Noise Figure @ max gain..10 dB typical; 3rd Order Intercept Point +69 dBm Harmoni cs @ 100-200 MHz, 200 500 MHz:; 2d&-40 typical, -30 Max dBc; 3d&-15/-25 max dBc; Spurious Signals..-70 dBc; Operating Voltage (3 Phase) &208 Vac AC Power Consumption @ 1000W CW..5000 max W; Input Overdrive...+10dBm max Load VSWR @ rated P1dB G.C.P..infinit e @ any angle/magnitude (nominal); Thermal Overload..85oC Shutdown Max; Dimensions =/greater than 17inx14inx22in; Weight =/greater than 150 lb max; RF Connectors Input/Output&Type N Female/SC-Type Female; Grounding..Chassis; Cooling&...Internal Forced Ai r; Operating; Temperature ..0o min/+50o max C; Non-Operating Temperature..-40 min/+85 max C; Operating Humidity&..95% min Non-Condensing; Operating Altitude 10,000 min/30,000 max ASL; Shock and Vibration Normal Truck or Trailer. 1 each, 1000  3000 MHz High Power Amplifier requirements. EPG intent is to purchase 1 broadband linear High Power RF Amplifier (HPA) system that is rated at of 100 watts (minimum) with minimum frequency coverage of 1000 to 3000 MHz. Technical requirements: The Linear HPA will be a small, self-contained, lightweight, air-cooled, broadband amplifier that provides instan taneous broadband signal generation to develop RF fields in an open field test site. The amplifier must be of rugged solid-state linear design. The amplifier will be housed in a single equipment rack and will provide a complete stand-alone performance fo r testing. HPA will be of a design that provides a high efficiency operation rate, proven reliability, low distortion and is stable across the frequency range. The HPA must provide high gain, wide dynamic range, low distortions and good linearity. Inpu t signals will be from signal generators that are both swept and stepped through the frequency band. The amplifier will be able to be controlled either locally or by remote. The amplifier's front panel must have a LCD Touchscreen digital display that pro vides extensive system status information accessed through a series of menus via soft keys. Status indicators include power on, warm-up, standby, operate, faults, excess reflected power warning and remote standby mode, VSWR protection, gain control, ALC on /off, forward and reflected RF output sample port, plus monitoring of the HPA amplifier critic al parameters. Front panel type-N connectors are required. The amplifier will have installed front handles. The amplifier must have thermal overload, over current and over voltage circuit protection. The HPA must also have an Ethernet Interface. REQUI RED SPECIFICATIONS: Minimum 2/year warranty. Must include a complete set of operator/system technical manuals. System must be delivered within 120 days of purchase. Frequency Range1000-3000 MHz,Output Power CW.100 min Watts,Power Output @ 1 dB G.C.P 80 Watts min, Power Gain @ 1 db G.C.P. .50 dB min,Input Power for rated output power .0 dBm nominal,Small Signal Gain Flatness + 2.0 dB max,Gain Adjustment&25 min dB, Input/Output Return Loss .-10 dB,Noise Figure @ max gain ..7 dB typical/10 dB max, 3rd Order Intercep t Point&+59 dBm,Harmonics @ 1dB G.C.P..-20 dBc,Spurious Signals .-70 dBc typical/-60 max,Operating Voltage (single Phase) &100 min/240 max Vac,AC Power Consumption .1400 max W,Input Overdrive ..+6dBm max,Load VSWR @ rated P1dB G.C.Pinfinite @ any angle/mag nitude (nominal),Thermal Overload..85oC Shutdown Max,Dimensions=/greater than 19inx8.75in22in, Weight=/greater than 80 lbs max,RF Connectors Input/OutputType N Female,Grounding ..Chassis,Cooling&...Internal Forced Air,Operating Temperature 0o min/+50o max C,Non-Operating Temperature .-40 min/+85 max C,Operating Humidity .95% min Non-Condensing,Operating Altitude&10,000 min/30,000 max ASL, and Shock and Vibration Normal Truck or Trailer. FOB DESTINATION: Fort Huachuca, Arizona. Payment will be made by Government credit card under Net 30 Terms. Offers are due no later than 12 noon, Mountain Standard Time, Monday, 2 July 2007. Offers shall be submitted electronically at: Carmen.simotti@epg.army.mil. EVALUATION CRITERIA/PROCEDURES: Offers will be evalu ated based on the following best value criteria in descending order of importance: Meeting the requirement, Proposed Delivery Schedule, Past Performance, and Price. The result of the award will be posted in Fedbizopps(http://www.fbo.gov/) under Award Not ices. Questions pertaining to the Award Notice must be submitted in writing. For additional information, contact Carmen M. Simotti, Contract Specialist, at (520) 533-8189 or carmen.simotti@epg.army.mil. The synopsis/solicitation document and incorporate d provisions and clauses are those in effect through Federal Acquisition Circular 2005-16. This is a Full and Open Requirement. The NAICS code is 334515. The solicitation is issued as a request for proposal (RFP) and will be awarded as a firm-fixed-pric e. All Electronic and Information Technology will be Section 508 of the Rehabilitation Act of 1973 compliant. The following FAR provision 52.212-1, Instruction to Offerors Commercial items, applies to the acquisition. FAR provision 52.212-2, Evaluation o f Commercial Items, applies to the acquisition (See evaluation criteria above). Offerors shall include a completed copy of FAR provision 52.212-3,Offeror Representations and Certifications Commercial Items, and furnish Offeror's Tax Identification Number, CAGE Code, Central Contractor Registration Number, DUNS Number, and applicable FSC Codes with its offer. FAR clauses 52.212-4, Contract Terms and Conditions Commercial Items and 52.212-5, Contract Terms and Conditions Required Implementing Statutes or Exec utive Orders Commercial Items apply to this acquisition. FAR clause 52.219-8, Utilization of Small Business Concerns apply. The government reserves the right to select for award, all, some, or none of the proposals received in response to this announcemen t.
 
Place of Performance
Address: ACA, Southern Region, Electronic Proving Ground (EPG) Banister Hall, SFCA-SR-WS. 2000 Arizona Street Fort Huachuca AZ
Zip Code: 85613-7063
Country: US
 
Record
SN01327147-W 20070627/070625220849 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.