MODIFICATION
83 -- ADDITIONAL INFORMATION
- Notice Date
- 7/31/2007
- Notice Type
- Modification
- Contracting Office
- ACA, Fort Bliss, Directorate of Contracting, Attn: ATZC-DOC, Building 2021, Club Road, Fort Bliss, TX 79916-6812
- ZIP Code
- 79916-6812
- Solicitation Number
- W911SG-07-T-0387
- Response Due
- 8/6/2007
- Archive Date
- 10/5/2007
- Small Business Set-Aside
- N/A
- Description
- Additional Information provided, response date is extended to August 6, 2007, 3:00 pm, local time. 1. Color of Structure to be heated and cooled: Any color. 2. Max Ambient Temperature that the structure will be deployed in: (110F) 3. Minimum Ambient Temperature that the structure will be deployed in: (8F) 4. Maximum number of personnel who will be working in the structure at any one time: 6 personnel 5. Maximum Electrical Heat Load that originated from within the structure: Computers and welding equip ment to be used as needed. 6. Desired Target Temperature (at worker level) for Interior of Structure: (70) 7. Is there a requirement for dherence to MIL-STD 810F (such as: external sling load certification, vibration, internal Air Craft load certification, salt fog, fungus, rail hump, cold weather 24 hr cold soak, dust/sand, etc.) or will Ruggedized (MCOTS/NDI) Commercial Off the Shelf be sufficient: Ruggedized 8. Do you desire Insulated Air Ducts or Non Insulated Air Ducts: Insulated 9. Do you desire the c olor of the Ducts to be the same color as the ECU: Yes 10. Do you desire Make up Air, (additional air introduced into the system thru a vent in the ECU): NO 11. Do you desire any NBC considerations: NO 12. Do you desire a remote Thermostat: NO 13. 400Hz EC U are typically used within the Aircraft/Aviation community. Do you need a discrete 400Hz unit or one that can operate on multiple Hertz basis (i.e. 50 Hz, 60Hz and 400Hz). 400 HZ 14. Is there a weight and size restriction; if yes, then please provide rele vant data: NO 15. Do you desire the ECU to be skid mounted; if yes, do you desire fork lift pockets, do you require lifting points: SKID MOUNTED,LIFTING POINTS 16. Do you desire the ECU to be trailer mounted: NO 17. Do you desire the ECU to have its own power source: N0 18. Is there a requirement for the Ducts to be stored inside the ECU for Transit and Long-term Storage: NO 19. Do you have a particular number of Air Changes an hour in the structure or do you have a particular minimum SCFM requirement; if yes, then please state the number of Air Changes or SCFM required: CONTINUOUS 20. Do you have a specified paint color for the ECU: NO 21. Do you have a requireme nt for the ECU to have CARC Paint: NO 22. Will the ECU be delivering the conditioned air to a tent duct plenum distribution system or simply dumped into the structure: No plenum distribution system. 23. Do you need one ECU to take care of this requirement or can multiple ECUs be used to meet the requirement: No preference 24.Do you have an maximum decibel level for the ECU; if yes, then what decibel level and at what number of meters: AS LOW AS POSSIBLE
- Place of Performance
- Address: ACA, Fort Bliss Directorate of Contracting, Attn: ATZC-DOC, Building 2021, Club Road Fort Bliss TX
- Zip Code: 79916-6812
- Country: US
- Record
- SN01357619-W 20070802/070731221556 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |