SOURCES SOUGHT

C -- AE Fire Alarm System Upgrade

Notice Date
3/21/2008
 
Notice Type
Sources Sought
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of Veteran Affairs;VA Medical Center (90 CSC);1481 West Tenth Street;Indianapolis IN 46202
 
ZIP Code
46202
 
Solicitation Number
VA-251-08-RI-0138
 
Response Due
4/2/2008
 
Archive Date
6/1/2008
 
Point of Contact
Aaron Lacy Aaron.Lacy@va.gov Deborah Barker Deborah.Barker@va.gov
 
E-Mail Address
Email your questions to Contract Specialist
(Aaron.Lacy@va.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned
 
Description
This acquisition is set aside for service disabled veteran owned small business (SDVOSB) and is restricted to firms located within a 150 mile radius of the Indianapolis, Indiana VA Medical Center 46202. This is NOT a Request for Proposal or SF330s and a solicitation document does not exist. Seeking Service Disabled Veteran Owned Small Businesses (SDVOSB) to provide all labor, material, equipment and expert supervision for a complete Fire Alarm (FA) Upgrade (to comply with ADA, NEC and NFPA regulations) to the Richard L. Roudebush, VA Medical Center Indianapolis, Indiana. This work includes C-wing and D-wing, all floors. A-wing floors have recently been brought up to ADA standards, but visual inspection and report is needed as part of this design contract. Design work includes testing, repairing, removal and additional FA devices in areas that are not compliant to ADA, NEC and NFPA regulations. A/E shall utilize latest VA design manuals and standards to provide additional layout for optimal and functional FA System, in addition to current design. A/E shall provide construction cost estimates, submittal tracking log, drawings and specifications at each of the two (2) design reviews (50% and 100%). Submittals shall be in triplicate along with an electronic version at each review stage allowing sufficient time for VA personal to review and provide comments. At the final submission A/E shall provide reproducible vellums and a CD-ROM copy of the plans in the latest Auto Cad version VA has available (currently A-CAD 2006). The A/E shall also provide three (3) sets of final documents (specifications and drawings) for the prospective bidders. In addition A/E shall provide construction period services and at the completion of construction, A/E shall provide as-built drawings via Auto Cad. Work shall include planning, phasing, testing, repairing, removal and additional FA devices to current system. Work will affect all other disciplines associated with architectural and MEP for a complete and functional facility. See the following: (1) Provide evidence of prior experience as well as provide reference projects of similar size, scope and design regarding the type of work mentioned above. (2) Design firm shall be capable of providing FA System analysis and associated type coordination studies. Existing FA System coordination study information will be made available by VA. This information will be required to be reviewed by A/E firm as part of each FA System Upgrade project. (3) Provide final working drawings and specifications to comply with applicable VA Construction Standards, Master Specifications, and other appropriate codes (NEC and NFPA) and VA directions. Provide complete drawings and technical specifications to meet VA standards as directed. (4) VA shall provide A/E with current FA drawings (for reference only) which shall be updated by A/E and given back to VA for As-Built purpose. Provide all working plans in 1" = 20'-0" scale or larger where needed for clarification. Edit specifications from VA Master Specifications. Prepare and coordinate all architectural, engineering, calculations, and specifications. Provide final construction documents at 100% review, complete and ready for construction. (5) Conduct site visits for the purpose of data gathering, investigation and documentation of all existing conditions. Perform such investigations as required to accurately verify all existing conditions. Do not rely solely upon "as built" drawings. VA personnel will provide assistance with investigating the project site where prior experience with equipment and utilities will produce an appreciable advantage. Any modifications that are required to be made as a result of the site review shall be communicated to VA and corrected by the A/E firm. (6) Provide detailed phased design for minimal interference with VA operations. In addition, provide a preliminary construction schedule which shall include a timeline for projected outages highlighting the facility interruption time frame of each area. This information shall be communicated to all bidders for their review and inclusion within their bids. It shall be communicated within the bid documents that the contractor will be required to review and provide any concerns regarding the projected construction timeline in order to minimize any/all disruptions to the facility. (7) Provide for the safety of all employees, contractors, visitors and others involved with the project site. (8) For all disciplines, provide complete specifications, edited from VA Master Specifications. Ensure that all specifications are edited and tailored for the specific work required and that they are fully coordinated with the contract drawings. Where the VA Master Specifications do not apply, develop and provide custom specifications as appropriate. (9) Provide complete details necessary to show all work required. Show extent of any demolition, cutting, etc., required along with all necessary details for repair/restoration. Include all modifications, rerouting etc., of existing services or construction serving other areas. (10) Provide diskettes of all drawings in AutoCAD 2006 format and specifications in Microsoft Word format. Provide as-built drawings of completed project work on diskettes as well as reproducible vellums (one set). In addition, provide as-built drawings on half size reproducible vellums (one set). (11) Reproduce specifications and drawings required for design reviews. Each review submission will include three (3) printed sets of drawings, specifications, and calculations, analyses when appropriate, and one (1) set of diskettes for specifications and drawings. (12) After final submission review, make any changes as noted by VA. Deliver the original construction documents to the VA Chief Engineer, after the final review comments are incorporated. The construction document drawings shall bear the seal of the Registered Architect/Professional Engineer licensed in the State of Indiana responsible for the design. (13) Project will not be advertised for Construction until final specifications and drawings are approved by the VA. (14) Perform and follow up on final inspection. Develop punch list for corrective action. Conduct a detailed inspection including mechanical/electrical spaces and all support areas covered by the contract. Develop punch lists and monitor corrective actions. The magnitude of construction range is between $250,000 and $500,000. This procurement is restricted to firms located within a 150 mile radius of the Indianapolis, Indiana VA Medical Center 46202. NAICS Code 541330, Engineering Services, Size Standard of $4.5 million is applicable to this acquisition. This is NOT a Request for Proposal or SF330s and a solicitation document does not exist. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Central Contractor Registration (CCR) database prior to award of a contract. Interested SDVOSB A/E firms are encouraged to respond no later than April 2, 2008 by email to Aaron.Lacy@va.gov AND Deborah.Barker@va.gov . VA Medical Center, ATTN: Aaron Lacy (90CSC), 1481 West 10th Street, Indianapolis, IN 46202. Information can also be submitted via overnight express service (NON-US Postal mail) to VA Contract Service Center Building 7, ATTN: Aaron Lacy, 2669 Cold Springs Road, Indianapolis, IN 46222
 
Place of Performance
Address: RLR VA Medical Center;1481 W. 10th Street;Indianapolis, Indiana
Zip Code: 46202
Country: US
 
Record
SN01538510-W 20080323/080321223615 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.