SOLICITATION NOTICE
65 -- Evo Tech
- Notice Date
- 6/4/2008
- Notice Type
- Presolicitation
- NAICS
- 423450
— Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Department of the Air Force, Direct Reporting Units, USAF Academy - 10 MSG/LGC, 8110 Industrial Drive, Suite 200, USAF Academy, Colorado, 80840-2315
- ZIP Code
- 80840-2315
- Solicitation Number
- Evotech
- Response Due
- 6/11/2008
- Archive Date
- 6/26/2008
- Point of Contact
- Patrica Richmond,,
- E-Mail Address
-
patricia.richmond@usafa.af.mil
- Small Business Set-Aside
- N/A
- Description
- Intent to Award Brand Name Evo Tech Endoscope Cleaner and Reprocessor 10th Mission Support Group, Directorate of Contracting, United States Air Force Academy Colorado, intends to award a brand name only commercial purchase order in accordance with FAR Parts 12 & 13. This notice document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-14, 22 Nov 06. The North America Industry Classification System Code [NAICS] is 423450 and the size standard is 500 employees. The requirement is to purchase: 1 each Product number 100012-01 Evo Tech™ GI Suite (1 each 50004,20398, 22591, 20302, 13004001), 1 each Part Number 09003104 CH SEP, OLY>=40 series, 1 each Part Number 09601103 SCOPE CON SET, OLY GI>=40. These items will require identification adhering to DFARS 252.211-7003 (http://farsite.hill.af.mil). The justification for the brand name requirement is as follows: a. This ECR is the only system with FDA clearance to automate manual cleaning. The Evo Tech System’s 33 minute cycle time includes the normally labor-intensive manual cleaning of the scope, which takes 6-10 minutes per scope. Additionally, this system automatically detects leaks thereby eliminatiing the inconsistencies associated with manual inspection. b. The Evo Tech ECR System has a large basin size (21 inches) this helps to prevent endoscope coiling, there potentially reducing endoscope repair costs. c. This system has an integrated MEC monitoring which assures precise results by eliminating the use of test strips. The single use of CIDEX OPA Concentrate Solution safely delivers fresh and consistent single metered dose of high level disinfectant every cycle. Technical Data of the EvoTech Endoscope Cleaner and Reprocessor System: Where marketed United States, Canada, New Zealand, Australia, and Singapore FDA Clearance Yes Configuration Floor, Stand-alone Mobility Moveable, 4 casters, 4 levelers Standard of Care High Level disinfection Air Capability Yes, to all internal channels Self-Disinfect Cycle Yes Overall Size Height (with lid closed) 117 cm (46 in) Height (with lid open) 150 cm (59 in) Width (without printer) 95 cm (37 in) Depth 82 cm (32 in) Weight (when empty) 226.8 kg (500 lbs) Operating Weight Approximately 254 kg (560 lbs) Basin Size 46.4 cm x 50.2 cm x 14.6 cm (18.25 in x 19.75 in x 5.75 in) Service Access Area 36 total inches needed on one side. Unit can be moved for service. Earthquake Restraint Unit includes attachment points Basins per System 2 Scopes per Basin 1 Scope Compatibility Submersible flexible fiber optic and video endoscopes suitable for high-level disinfection Cycle Time 33 minutes Germicidal Agents Approved Agents CIDEX® OPA Concentrate Solution Water Supply Hardness Water less than 50 PPM (CaCO3 Equivalent) Type Reverse Osmosis (RI) and Deionized (DI) water cannot be used in the EvoTechTM ECR System. Filter 0.2 micron bacterial filtered water Water Pressure 40 PSI (275 kPa) minimum dynamic pressure during flow rate of 6 liters per minute per machine Maximum static pressure is 100 PSI for the EvoTech System. Check water filtration manual for maximum water filtration static pressure. Water Temperature 5º C to 30º C (41º F to 86º F) Please note: Hot water is not required. A water heater is included in EvoTech ECR System Thermal Expansion Tank Included, wall mounted. Please note: Facility must install brackets for the thermal expansion tank prior to installation of the EvoTechTM ECR System. Detergent Type CIDEZYMETM GI Enzymatic Detergent Injection Yes, automatic Alcohol Reservoir Size 0.5 liter Percentage 70% EvoTechTM Endoscope Cleaner and Reprocessor (ECR) Information Input/Output Display 6.4-inch Color VGA Hard Copy Printout Control Interface Microprocessor Input Touch Screen Power Specifications AC Power 208 V, 3~, 60Hz, 30 Amp. USA, Canada 220-230 V, 50Hz, 50 Amp. Singapore 240 V, 50Hz, 50 Amp. Australia 220-230 V, 50Hz, 50 Amp. New Zealand Power outlet must be ground fault protected. A recommended ground fault circuit interrupter (GFCI) for 3-phase 208V system includes 3-phase Delta connection with no neutral and Auto Power Recovery on power loss. Electrical Connection 3-phase NEMA, L 15-30 Printer Connection 90-240 V Power Cord Length Approximately 6 feet Drain Specifications Number of Drains The left and right basins each has a drain tube. There is a shared overflow detector Drain Capacity 25 liters/min. per drain Maximum Temperature 75° C (167° F) Drain A 38 inch high (minimum) 42 inch high (maximum), from the floor, vented stand pipe, 2.5 to 3 inches in diameter, or 2 each 1.5 inch diameter, vented stand pipes must be in place for the waste discharge hoses. The pipes MUST NOT be capped. One end of the discharge hose should be connected (permanent connection) to the drain hose barb fitting on the EvoTechTM ECR System. The other end is inserted into the stand pipe. Please consult your local water municipality for any region-specific requirements. Operating Conditions Min. Room Temperature 15° C (59° F) Max. Room Temperature 30° C (86° F) Air Exchange Rate 12 times per hour Relative Humidity 10 - 80% non condensing Elevation -100 to 3,000 meters (-330 to 9,900 feet) Tilt up to 1 degree from vertical Heat Load Normal Cycle 1200 Watt (4000 BTU/hr) Self Disinfection Cycle 2000 Watt (7000 BTU/hr) Idle 300 Watt (1000 BTU/hr) Printer Information Printer Black and white printer included. Should be GFI protected. Printer Support The printer rests on either side of the system on the provided support (brackets are included). The printer can also be located on a nearby shelf. Printer brackets can fit up to a 195 mm x 195 mm printer. Printer brackets extend approximately 220 mm from the system. Printer Connection Serial cable CE Mark Yes Configuration Wall-mounted Self-Sanitize Cycle Yes Filter Media 1.0 micron Filter Polypropylene depth media 0.2 micron Filter Polypropylene polysulfone Water Supply Incoming Pressure 2.76 to 4.14 bar (40 to 60 PSI) Maximum pressure shall not exceed 5.52 bar (80 PSI) Pressure Differential 1.0 micron Filter 3.33 bar (50 PSI) 0.2 micron Filter 2 bar (30 PSI) Temperature 5º C to 30º C (41º F to 86º F) Power Specifications Voltage 100, 120, 230, 240 VAC (selectable), 50/60 Hz single phase Water Filtration System should be GFI protected. Fuses 100-120 VAC, 1 4A 3AG (1.25 in x 0.25 in) 220-240 VAC, two T2A (5 mm x 20 mm) Light Bulbs 12 V incandescent with slide base Overall Size 706.1 mm W x 701 mm H x 165.1 mm D (27.8 in W x 27.6 in H x 6.5 in D) Weight Wall mounting must support 44.5 kg (100 lbs) Filled with water ~16 kg (35 lbs) Water Filtration Plate Mounting brackets are required to be installed by facility prior to ASP Water Filtration System (Mounting Plate) installation Description The Water Filtration System from Advanced Sterilization Products is designed to filter out sediment found in municipal water sources and to provide bacteria-free and reduced pyrogen water for use in endoscope reprocessing. The convenient wall-mounted design includes a 1.0 micron filter to remove larger particles and sediment, and a 0.2 micron filter to remove fine particles and bacteria from the incoming water source. All responsible sources may submit a response, which if timely received, will be considered by 10MSG/LGCB. The Government does not intend to pay for any information provided under this presolicitation notice. Point of Contact is Sam Richmond, Contract Specialist (719) 333-3948 email: (patricia.richmond@usafa.af.mil) or alternate Leslie Ryan, Contracting Officer (719) 333-3961 email: leslie.ryan@usafa.af.mil. 5352.201-9101 OMBUDSMAN (AUG 2005) (a) An ombudsman has been appointed to hear and facilitate the resolution of concerns from offerors, potential offerors, and others for this acquisition. When requested, the ombudsman will maintain strict confidentiality as to the source of the concern. The existence of the ombudsman does not affect the authority of the program manager, contracting officer, or source selection official. Further, the ombudsman does not participate in the evaluation of proposals, the source selection process, or the adjudication of protests or formal contract disputes. The ombudsman may refer the party to another official who can resolve the concern. (b) Before consulting with an ombudsman, interested parties must first address their concerns, issues, disagreements, and/or recommendations to the contracting officer for resolution. Consulting an ombudsman does not alter or postpone the timelines for any other processes (e.g., agency level bid protests, GAO bid protests, requests for debriefings, employee-employer actions, contests of OMB Circular A-76 competition performance decisions). (c) If resolution cannot be made by the contracting officer, concerned parties may contact the USAF Academy Ombudsmen, Lori Staples 8110 Industrial Drive, Ste 103 USAFA, CO 80840 Telephone number 719-333-3907 FAX 719-333-9018 email: lori.staples@usafa.af.mil Concerns, issues, disagreements, and recommendations that cannot be resolved at the MAJCOM/DRU level, may be brought by the concerned party for further consideration to the Air Force ombudsman, Associate Deputy Assistant Secretary (ADAS) (Contracting), SAF/AQC, 1060 Air Force Pentagon, Washington DC 20330-1060, phone number (703) 588-7004, facsimile number (703) 588-1067. (d) The ombudsman has no authority to render a decision that binds the agency. (e) Do not contact the ombudsman to request copies of the solicitation, verify offer due date, or clarify technical requirements. Such inquiries shall be directed to the Contracting Officer. (End of clause) Point of Contact(s): Sam Richmond, Contract Specialist, Phone 719-333-3948, Fax 719-333-9103, Email patricia.richmond@usafa.af.mil
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=8b238a67446fa4d42a820b283590279e&tab=core&_cview=1)
- Place of Performance
- Address: 8110 Industrial Drive, USAF Academy, Colorado, 80840, United States
- Zip Code: 80840
- Zip Code: 80840
- Record
- SN01586853-W 20080606/080604220237-8b238a67446fa4d42a820b283590279e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |