SOURCES SOUGHT
Z -- WPAFB Construction - Replace Water System Mains, Area B, PhaseII
- Notice Date
- 6/5/2008
- Notice Type
- Sources Sought
- NAICS
- 237110
— Water and Sewer Line and Related Structures Construction
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, ASC - Aeronautical Systems Center, 1940 Allbrook DriveSuite 3Wright-Patterson AFB, OH
- ZIP Code
- 00000
- Solicitation Number
- FA8601-08-R-0036
- Response Due
- 6/10/2008
- Archive Date
- 1/6/2009
- Point of Contact
- Patricia Long, (937) 522-4576
- Small Business Set-Aside
- Service-Disabled Veteran-Owned
- Description
- Sources Sought Notice: The Air Force is seeking sources for apotential 100 percent set-aside for HUBZone, or Service Disabled Veteran Owned Small Business (SDVODS) concerns. IF ADEQUATE RESPONSES ARE NOT RECEIVED, THE ACQUISITION MAY BE SOLICITED ON AN UNRESTRICTED BASIS. This is a sources sought for planning purposes only: TITLE/DESCRIPTION: Replace Water System Mains, Area B, PH II., Project 0300232. Phase II of this project includes replacing a certain section of water mains between 5th and 10th. Water mains were installed in 1940s. DOLLAR VALUE: $1,000,000 to $5,000,000 SPECIAL REQUIREMENTS/CONCERNS: Restrictive conditions include that the contractor is working on an active potable water system that serves a large part of Area B. Each time the system is taken down for repairs, contaminants can enter the water system. If any contamination to the water system is suspected, flushing of the applicable lines is required along with the requisite testing to ensure the water is not contaminated PERFORMANCE PERIOD: 180 days This is not a notice of solicitation issue. This Sources Sought Notice does not constitute a Request for Proposal (RFP) or an Invitation for Bid (IFB), nor does this issuance restrict the Governments acquisition approach. The North American Industry Classification System (NAICS) code is 237110. PRIME contractors who are HUBZone and/or SDVOSB and who intend to submit a bid for this solicitation MUST submit the following by 2:00 p.m. (local Dayton, OH time) on 10 June 2008: (1) a positive statement of your intention to submit a bid for the forthcoming solicitation as a Prime Contractor; (2) date of HUBZone and or SDVOSB certification; (3) listing of experience in work similar in type and scope that you identified to include contract numbers, project titles, dollar amounts, and points of contact with their current phone numbers; (4) evidence of capability to be bonded for bid, performance and payment bonds; (5) if you are a HUBZone considering a joint venture, you will need to provide proof that this consideration has been forwarded to the cognizant SBA office for approval. Firms interested should provide the above documentation; e-mail and faxed responses will be accepted. All of the above must be submitted in sufficient detail for a decision to be made on the availability of interested HUBZone or SDVOSB concerns. Responses shall be limited to five (5) pages. Failure to submit all information requested would result in a contractor being considered not interested in this requirement. The mailing address for responses is 88 CONS/PKC, 1940 Allbrook Dr, Ste #, Wright-Patterson AFB, OH 45433-5309. The solicitation/RFP will be issued electronically. It will be posted on the Federal Business Opportunities (FedBizOpps) website at: http://www.fedbizopps.gov/ and the Wright-Patterson AFB Pre-Award Information Exchange System (PIXS) website at: https://www/pixs/wpafb.af.mil/. NO HARD COPIES WILL BE ISSUED FOR ANY REASON. The Department of Defense (DoD) has determined the Central Contractor Registration (CCR) to be the Single DoD registration for contractors who conduct business or who are interested in conducting business with the Department. Defense procurement and finance policies require contractors to be registered by for consideration in future solicitations, awards, and payment. DoD contracting officers worldwide will use CCR to identify sources and financial officers will use it to make payments. To register in CCR, you may use one of the following methods:(a) call telephone number 1-888-CCR-2423 for further information.(b) Input directly to CCR through the interactive World Wide Web application at http://www.ccr.gov/. Contractors must be registered in CCR prior to award for any solicitations. For more information on "WPAFB Construction - Replace Water System Mains, Area B, Phase II", please refer to: https://www.pixs.wpafb.af.mil/pixs_solicitation.asp?id=5659
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=ab8d741aecfdb262a38702c32135021d&tab=core&_cview=1)
- Place of Performance
- Address: Area BWPAFB, OH
- Zip Code: 45433
- Zip Code: 45433
- Record
- SN01587912-W 20080607/080605220942-ab8d741aecfdb262a38702c32135021d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |