Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 13, 2010 FBO #3003
SOURCES SOUGHT

C -- Design Unit Control Panels - Nimbus Powerplant

Notice Date
2/11/2010
 
Notice Type
Sources Sought
 
Contracting Office
Bureau of Reclamation - MP - Regional Office 2800 Cottage Way, Room E-1815 Sacramento CA 95825
 
ZIP Code
95825
 
Solicitation Number
R10PS20106
 
Response Due
2/22/2010
 
Archive Date
2/11/2011
 
Point of Contact
Teena A. Glasper Contract Specialist 9169785211 tglasper@usbr.gov;
 
E-Mail Address
Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
 
Small Business Set-Aside
N/A
 
Description
This announcement is to: (1) HUBZone, (2) 8(a) Small Business, (3) Service Disabled Veteran and (4) Small Business concerns that may be interested in performing a contract for the Mid-Pacific Region of the Bureau of Reclamation. The work to be performed is described below. Based upon response to this announcement, the Government may determine to set this acquisition aside or proceed with an unrestricted solicitation. The applicable North American Industry Classification System (NAICS) Code is 541310 and the related small business size standard is $4.5M. This notice is not a request for proposal and the information presented in this announcement will not obligate the Bureau of Reclamation in any manner. The estimated cost of this project is between $25,000 amd $100,000. Work is located at the Bureau of Reclamation Nimbus Powerplant, Sacramento, California. All interested parties are encouraged to respond to this notice, by e-mail to tglasper@usbr.gov no later than 1:00 PM PST on 2/22/2010. The information provided in this announcement is all the information the Government has available at this time. There are no specifications, drawings, bid packages, or source lists available. Interested parties should include the following information in their response: (a) Business name, address, cage code, size classification based on NAICS size standard, socioeconomic classification (i.e. HUBZone and/or 8(a)), and a point of contact; (b) A positive statement of your intention to submit an offer for this solicitation as a prime contractor; (c) Evidence of your experience performing work similar in type and scope to the work in this announcement within the last five years. The evidence should include: contract numbers, project titles, dollar amounts and points of contacts with telephone numbers. Please do not include more than three past projects; and (d) Include attachments cataloging the company's equipment assets, personnel resources and financial resources that demonstrate company responsibility and capability to perform required work.(e) If bonding is required, also provide evidence of your bonding capacity; The principal components of the work to be performed include: The scope includes the design, manufacture, shop testing and erection, installation testing, commissioning and training of bureau personnel on all the new unit control panels. The control panels will contain hard -wired sequencing relays and/or computer based automation systems (PLC's) for the operation, control, and monitoring of the power plant, transformer, and station service equipment either locally or remotely, from any control point. The scope includes data logging, alarm monitoring, unit control, digital governor conversions, solid state protection, metering, digital excitation and digital voltage regulation and solid state unit excitation and other components for making the system complete and to ensure a trouble free and safe operation. The Nimbus Power Plant is comprised of the following major components: 1. 2- 7.5MW Synchronous Generating units, Kaplan turbines being the prime mover and synchronized at 4.16 kV, rotating excitation and hydraulic governing systems2. 1 step up transformer of the rating 4.16 kV/115 kV, 12.5MVA3. 2-4.16 kV Feeders4. 2- 300 kVA, 4.16 kV/480 V station service transformers
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/5dd768b87c6e013a8d34926d30ffda6a)
 
Place of Performance
Address: Nimbus Powerplant - Sacramento, CA
Zip Code: 95825
 
Record
SN02063457-W 20100213/100211234805-5dd768b87c6e013a8d34926d30ffda6a (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |