MODIFICATION
30 -- HYDRAULIC POWER SUPPLY STATION
- Notice Date
- 3/12/2010
- Notice Type
- Modification/Amendment
- NAICS
- 333319
— Other Commercial and Service Industry Machinery Manufacturing
- Contracting Office
- NASA/George C. Marshall Space Flight Center, Procurement Office, Marshall SpaceFlight Center, AL 35812
- ZIP Code
- 35812
- Solicitation Number
- NNM10320402Q
- Response Due
- 3/16/2010
- Archive Date
- 3/12/2011
- Point of Contact
- Betty C. Kilpatrick, Contract Specialist, Phone 256-544-0310, Fax 256-544-6062, Email betty.c.kilpatrick@nasa.gov - Marianne R. Campbell, Contract Specialist, Phone 256-544-6496, Fax 256-544-0236, Email Marianne.R.Campbell@nasa.gov
- E-Mail Address
-
Betty C. Kilpatrick
(betty.c.kilpatrick@nasa.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- This is modification No. 5 to the synopsis entitled Hydraulic Supply StationNNM10320402Q which was posted on 01/06/2010. You are notified that the following changesare made: Please review below changes to the SOW for the Hydraulic Power Supply Station. Please revise your proposal according to the listed changes below. Please submit yourrevised proposal to Pamela Jackson,DFI Inc. at Pamela.l.Jackson@NASA.GOV on or before3/16/10 4:30 CST. Listed Changes:1. (On Page 31 of the Procurement Spec, sec 3.6.3.2)Was: The motor starters, overloads, transformer, phase rotation devices, and circuitbreakers shall be contained in a NEMA 4XC disconnect enclosure with interlock rated forminimum amperage utilized.Now: The motor starters, overloads, transformer, phase rotation devices, and circuitbreakers shall be contained in a NEMA 3R, NEMA 4, or NEMA 4X disconnect enclosure withinterlock rated for minimum amperage utilized.Change: NEMA 3R Motor Control Center Enclosures are now acceptable2. (On MED03191 and Page 40 of the Procurement Spec, sec 3.6.5.2.3.1)Was: Each main hydraulic pump outlet and case drain shall have a flowmeter with a signalconditioner for local and remote readings as shown in MED03191.Now: Each main hydraulic pump case drain shall have a flowmeter with a signal conditionerfor local and remote readings as shown in MED03191.Change: All four (4) main hydraulic pump outlet flowmeters removed.3. (On MED03191 and Page 13 of the Procurement Spec, sec 3.2.1, Table 1)Change: Return Line Filter removed, including its associated delta pressure transducers,gauges, and valves.4. (On MED03191 and Page 25 of the Procurement Spec, sec 3.6.1.2.2.9)Change: All four (4) accumulator discharge valves removed.The due date for responses is on or before 3/16/2010 4:30 CST.Documents related to this procurement will be available over the Internet. Thesedocuments will reside on a World Wide Web (WWW) server, which may be accessed using a WWWbrowser application. The Internet site, or URL, for the NASA/MSFC Business Opportunitieshome page is http://prod.nais.nasa.gov/cgi-bin/eps/bizops.cgi?gr=D&pin=62 Offerors are responsible for monitoring this site for the release of the solicitation andany amendments. Potential offerors are responsible for downloading their own copy ofthe solicitation and amendments (if any).
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/NASA/GMSFC/POVA/NNM10320402Q/listing.html)
- Record
- SN02091271-W 20100314/100312235836-3ac1fdc83fd6f510f92671a704b2730e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |