SOURCES SOUGHT
61 -- Market Survey for Power Supplies, PP-2953()/U and PP-6224()/U
- Notice Date
- 3/23/2010
- Notice Type
- Sources Sought
- Contracting Office
- CECOM Contracting Center (CECOM-CC), ATTN: AMSEL-AC, Building 1208, Fort Monmouth, NJ 07703-5008
- ZIP Code
- 07703-5008
- Solicitation Number
- MARKET-SURVEY-4805-1
- Response Due
- 4/16/2010
- Archive Date
- 6/15/2010
- Point of Contact
- Andreas Deverikos, 000-000-0000
- E-Mail Address
-
CECOM Contracting Center (CECOM-CC)
(andreas.deverikos2@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Market Survey for Power Supplies, PP-2953()/U and PP-6224()/U FOR MORE INFO PLEASE CONTACT Ari Herman, Electronics Engineer, 732-532-6763 DESC Sources are sought for long term production of Tactical Power Supplies PP-6224()/U and PP-2953()/U, and their associated Technical / Repair Manuals. The power supplies furnish 0-25 amperes over a voltage range of 24 to 32VDC from nominal 115/230 VAC at 50, 60 or 400 Hz single phase. The power supply can also operate from a 24 VDC storage battery in the battery standby mode. Full technical details of the power supplies can be found in MIL-PRF-49080 Revision D found at https://assist.daps.dla.mil/quicksearch/basic_profile.cfm?ident_number=26824 Note: The newly released Revision D contains new requirements and many differences relative to Revision C. The power supplies will be designed to be field maintainable with full instructions included in the Technical Manual. The power supplies will be required to undergo First Article Testing, will require configuration management control, and undergo periodic production testing. Details of testing can be found in the aforementioned MIL-PRF-49080 Rev D. Any interested sources shall indicate so by emailing ari.herman@us.army.mil by April 16 2010. THIS IS NOT A SOLICITATION; no award will be made as a result of this request. This market survey is for informational purposes only; this is not a Request for Proposal (RFP). All interested parties are encouraged to respond to the market survey. The Government is in no way obligated to the offeror by the information received. FOR MORE INFO PLEASE CONTACT Ari Herman, Electronics Engineer, 732-532-6763
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/4f3cb1e54508d9a7b9ebd95c3e7f1739)
- Place of Performance
- Address: CECOM Contracting Center (CECOM-CC) ATTN: AMSEL-AC, Building 1208 Fort Monmouth NJ
- Zip Code: 07703-5008
- Zip Code: 07703-5008
- Record
- SN02100723-W 20100325/100324000357-4f3cb1e54508d9a7b9ebd95c3e7f1739 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |