FBO DAILY ISSUE OF APRIL 22, 2010 FBO #3071
SOLICITATION NOTICE

66 -- High-Pressure Syringe Pump.

Notice Date
4/20/2010
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333911 — Pump and Pumping Equipment Manufacturing
 
Contracting Office
U.S. DOE/NETLPittsburgh Campus626 Cochrans Mill RoadPO Box 10940PittsburghPA15236-0940
 
ZIP Code
15236-0940
 
Solicitation Number
DE-SOL-0001771
 
Response Due
5/5/2010
 
Archive Date
6/4/2010
 
Point of Contact
Stumpf,LoraL 412-386-4675 stumpf@netl.doe.gov
 
E-Mail Address
Stumpf,LoraL
(stumpf@netl.doe.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Laboratory-Scale Precision High-Pressure Syringe Pump per Attachment #1 Technical Requirements/Specifications. NOTICE: All Technical Questions Concerning This Requirement Should be Directed to Mr. Robert Warzinski at 412-386-5863. NOTICE: Vendors are strongly encouraged to submit their Request for Quotation (RFQ SF-18) or proposal(s) via the FEDCONNECT.NET portal at www.fedconnect.net. Request for Quotation (RFQ SF-18) or proposal(s) shall also be accepted via email. Vendors may email their RFQs or proposal(s) to the Purchasing Agent assigned to this requirement, who is Lora Stumpf (412-386-4675), email address lora.stumpf@netl.doe.gov. EVALUATION/SELECTION CRITERIA:Selection Criteria: The primary criteria that will be used for selection are listed below. In achieving the goals of this solicitation, performance of the system may override pricing considerations. - Pressure range and control. - Flow range and control.- Delivery volume and control. - Accuracy and stability of pressure and flow. - Corrosion resistance.- Versatility. Pump functions capable of local and remote control. - Safety. All electrical systems shall meet national standards. All pressure design must conform to NETL/ORD Approved Engineering and Design Codes, which are part of this solicitation. - Noise. Quiet operation of the pump is desired. A description of the maximum noise level shall be provided. - Footprint. The laboratory area that is to contain the pump(s) is not large and must accommodate other equipment; therefore, the footprint of the unit will be a significant consideration in selection. The vendor shall indicate if the pump can operate in different orientations that may reduce its footprint and whether these alternate orientations are achievable without addition support. Guidance: It is highly recommended that vendors respond directly to these Technical Requirements/Specifications that are attached to this solicititation and to this Selection/Evaluation Criteria. Simply supplying a standard company quote without specifically addressing these items may result in disqualification from consideration. The ability to adequately meet NETL's particular needs in these matters must be addressed in a clear and concise manner. It is possible that not all of the requirements can be met; therefore, potential bidders shall clearly define their pump's strengths and weaknesses with respect to the attached requirements and clearly point out any limitations or variances. Pricing shall be provided per individual pump, with any discounts shown for purchasing two pumps.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/PAM/HQ/DE-SOL-0001771/listing.html)
 
Record
SN02127157-W 20100422/100420235357-6a5e0c3d495d5a13f52d22e6352fb885 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.