Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 18, 2010 FBO #3220
SOLICITATION NOTICE

J -- Preventive Maintenance checks and services for facility Uninterruptible Power Supply, 480 Volt sys

Notice Date
9/16/2010
 
Notice Type
Presolicitation
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
Department of Veterans Affairs;Rocky Mountain Network;VISN 19 Contracting;500 Foothill Drive;Salt Lake City, UT 84148
 
ZIP Code
84148
 
Solicitation Number
VA25910RP0274
 
Response Due
9/23/2010
 
Archive Date
10/8/2010
 
Point of Contact
Glenn Breitling
 
E-Mail Address
Breitling@va.gov<br
 
Small Business Set-Aside
N/A
 
Description
VA-259-10-RP-0274 The George E. Wahlen VA Medical Center, Salt Lake City, Utah, has a requirement for preventive maintenance checks, services and emergency repair for an Uninterruptible Power Supply, Powerware UPS Model #500 AC in 480 V system. Services are anticipated to be from the base year of Oct 1, 2010 through September 30, 2011, with four (4) - one-year option periods. All prospective offerors must apply for and receive a Dun and Bradstreet Number @ www.dnb.com, register at www.ccr.gov, have a current Online Registration & Certification (ORCA) at https://orca.bpn.gov/ and if a Veteran owned business be registered in the VetBiz.gov vendor information pages at http://www.Vetbiz.gov. The North American Industry Classification System Code for this solicitation is 335311. Statement of Work Maintenance, Service and Repair Agreement for: Equipment: Eaton Powerware UPS model 9315-500 480 V AC Base year with 4 -one year option periods Provide 24 hrs / day and 7 days per week for 365 days maintenance service and repair support. This would include all parts, labor, and expenses for the UPS unit. Battery replacement would not be included. Provide list of all parts, supplies and services that would be included in the maintenance service agreement for both the UPS and the batteries and cabinets. Include provision for discounted pricing on parts and service that extends beyond the coverage in the basic agreement. Due to the need for patient care and safety, this agreement must provide service priority over other non-contracted customers. Provide two preventive maintenance service checks, adjustments and services on a schedule to be determined on the UPS and all of the batteries and cabinets. Be able to respond with technical support on site within 4 hours with service technicians that are factory trained and certified. All repairs and services must meet manufacturer/factory standards. All parts to be factory authorized and approved. Provide web access to account information and site service activity.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/SLCVAMC660/SLCVAMC660/VA25910RP0274/listing.html)
 
Place of Performance
Address: VA Health Care System;George E. Wahlen Medical Center;500 Foothill Drive;Salt Lake City, UT 84148
Zip Code: 84148
 
Record
SN02284253-W 20100918/100916235334-7b1755abbe97757e2521695541532528 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |