Z -- RECOVERY--Z--FOX POINT HURRICANE BARRIER - Upgrades to the ElectroMechanical Control System, Providence, RI
- Notice Date
- 10/1/2010
- Notice Type
- Award Notice
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- USACE District, New England, 696 Virginia Road, Concord, MA 01742-2751
- ZIP Code
- 01742-2751
- Solicitation Number
- W912WJ10B0014
- Response Due
- 9/9/2010
- Archive Date
- 11/8/2010
- Point of Contact
- Brad Schweitzer, 978-318-8022
- E-Mail Address
-
USACE District, New England
(brad.a.schweitzer@usace.army.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W912WJ-10-C-0032
- Award Date
- 9/29/2010
- Awardee
- RYAN COMPANY, INC. THE (019397728)<br> 25 CONSTITUTION DR<br> TAUNTON, MA 02780-1071
- Award Amount
- $908,269.00
- Line Number
- 0001
- Description
- Fox Point Hurricane Barrier is a 700-foot long concrete barrier and includes a pump station with five 4,500hp pumps and three 40-foot by 40-foot tainter gates. The project also includes 2,200 feet of dikes. Fox Point provides protection to tens of thousands of residents and $5 billion worth of property. Lately, the operation of the pumps at the Fox Point Hurricane Barrier has become unreliable due to an antiquated control system. The purpose of this work is to improve station service reliability and provide a modern, up-to-date electromechanical control system. The following electrical upgrade work must be accomplished. The construction contract work includes: - Replacement of 8 existing 4160V switchgear and relays with vacuum breaker switchgear and digital multifunction protection relays. Remote breaker racking to be included; - Relocation/replacement of existing pump and gate controllers and replacement of annunciator relay system with a digital Programmable Logic Controller (PLC); - Replacement and relocation of existing pump station battery system used to trip the 4160V breakers; - Replacement of 5KV power cables from each of five 4500 hp electric pumps to the switchgear; - Diagnosis/repairs to the nitrogen cooling system on 11KV electric transformers; - ARC Flash Hazard analysis, testing, certification.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA33/W912WJ10B0014/listing.html)
- Record
- SN02304650-W 20101003/101001234347-4c5486506595b07498eee945f933a3f9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |