MODIFICATION
R -- Remove and return to storage, stoplogs currently in place, U.S. Army Corps of Engineers, Operations Division, Raystown Lake, Hesston, PA - Solicitation 1
- Notice Date
- 10/4/2010
- Notice Type
- Modification/Amendment
- NAICS
- 561990
— All Other Support Services
- Contracting Office
- USACE District, Baltimore, 10 South Howard Street, Baltimore, MD 21203
- ZIP Code
- 21203
- Solicitation Number
- W912DR-11-T-0005
- Response Due
- 10/21/2010 2:00:00 PM
- Archive Date
- 12/20/2011
- Point of Contact
- Josephine E. Baran, Phone: 410-962-0972, Dean R. Whitmore, Phone: 814-658-3405
- E-Mail Address
-
Josephine.E.Baran@usace.army.mil, dean.r.whitmore@usace.army.mil
(Josephine.E.Baran@usace.army.mil, dean.r.whitmore@usace.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Solicitation will be available to FBO registered contractors to login with their login and password to view/download/print out the solicitation documents by 4:00 PM 10/04/2010. Submit responses to solicitation (RFQ) to USACE, BALTIMORE, 10 S. HOWARD STREET, ROOM 7000, ATTN: J. BARAN, CONTRACTING DIVISION, BALTIMORE, MD 21201 not later than 2:00 PM, 21 October 2010. The CONTRACTOR shall furnish all labor, material, supplies and equipment, including equipment operators, necessary to perform the work. The work is to be performed under the direction of the Contracting Officer or the Authorized Representative of the Contracting Officer and includes, but is not limited to, the following technical specifications. The major elements of the project include: a. Removal of 27 stoplogs (dive activity) b. Return stoplogs to storage. 1.1.2.1 Truck Mounted Crane a. A 30-ton (or less) truck-mounted crane shall be used for removal of stoplogs. During transport, the stoplogs shall be kept parallel to the spillway deck. If a crane is utilized to transport stoplogs, they may be transported perpendicular to the spillway deck if elevated at least 15 feet above deck to clear light stands. b. Only one pair of the cranes outriggers will be able to fully extend. The other pair will need to be kept within 14-0 rail-to-rail width of spillway bridge. c. The Government will supply certified lifting chains for the stoplogs, however they shall be installed by the contractor and shall meet the requirements of drawing S-08. If the contractor chooses, he may provide his own lifting slings in accordance with drawing S-08. d. Crane must be capable of safely lifting 3,800 lb (dry stoplogs), plus weight of cables, hook block, lifting slings and any incidental impact load or friction anticipated by the Contractor. When stoplogs is pulled out of the water, it is possible for the load weight to briefly be 5,800 lbs, which assumes water trapped above the web and between flanges. It is anticipated that the drain holes provided in the stoplogs will allow this water to drain rapidly, lowering the weight back to 3,800 lbs. Lifting radius and boom length during placement can be determined from requirements and dimensions shown on drawings. Lifting radius and boom length required for picking stoplogs off flatbed trailer shall be determined by Contractor. P.O.C. USACE, CONTRACTING DIVISION - josephine.e.baran@usace.army.mil (410)962-0972(v) (410)962-2001 (f); USACE, RAYSTOWN LAKE, TECHNICAL P.O.C. AND TO MAKE ARRANGEMENTS FOR SITE VISIT - dean.r.whitmore@usace.army.mil (814)658-3405 ext 2803
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA31/W912DR-11-T-0005/listing.html)
- Place of Performance
- Address: Raystown Lake Project, 6145 Seven Points Road, Hesston, Pennsylvania, 16647, United States
- Zip Code: 16647
- Zip Code: 16647
- Record
- SN02305035-W 20101006/101004234231-b31ff208b4054231b4f34eab8644a144 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |