SOURCES SOUGHT
58 -- FMS Case IS-B-ZUF (Israel) Night Vision System
- Notice Date
- 11/17/2010
- Notice Type
- Sources Sought
- Contracting Office
- CECOM Contracting Center (CECOM-CC), ATTN: AMSEL-AC, Building 1208, Fort Monmouth, NJ 07703-5008
- ZIP Code
- 07703-5008
- Solicitation Number
- MARKET-SURVEY-4980-1
- Response Due
- 11/24/2010
- Archive Date
- 1/23/2011
- Point of Contact
- Harold Schwake, 000-000-0000
- E-Mail Address
-
CECOM Contracting Center (CECOM-CC)
(harold.schwake@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- FOR MORE INFORMATION CONTACT:Ritsa Karakanas 732-532-8603 OR John Padre 732-532-8630 Ritsa Karakanas, EMAIL Ritsa.Karakanas@us.army.mil OR John Padre, EMAIL john.padre@us.army.mil **You must respond NO LATER than the Respond Date and Time The US ARMY CECOM LCMC intends to acquire the following: 1,435 each commercial export Image Intensifier Tubes GEN III NTE 1600 FOM Salient Characteristics: Resolution: 64 lp/mm Signal to Noise Ratio (minimum): 21 High-Light Resolution @ 20 fc (minimum): 12 Photocathode Sensitivity (Minimum) @2856: K, A/lm: 1800 @880 nm, mA/W: 80 Halo, mm (minimum): 0.85 EBI, X10^-11 lm/cm^2 (Maximum) 2.5 Luminous Gain, fL/fc @2X10^-6 fc: 40000-7000 @2X10^-4 fc: 10000 Output Brightness, fL@1 and 20 Fc: 2.0-4.0 Output Brightness, Uniformity (Maximum) @2856K and @880 nm: 3.1 MTF (Minimum) @2.5 lp/mm: 92% @7.5 lp/mm: 80% @15.0 lp/mm: 61% @25.0 lp/mm: 38% Maximum Spots Allowed in Each Zone: Zone Spot Size (in.): 1 2 3 greater than.012 or Larger: 0 0 0 greater than.009.012:0 0 0 greater than.006.009:0 1 1 greater than.003.006:0 2 2 Information/Requirements: 1. Figure of Merit must not exceed 1600 FoM, Resolution must be 64 lp/mm and minimum Signal to Noise Ratio is 21 2. If you are a reseller/distributor you MUST disclose the manufacturer of the Tubes. 3. You MUST state delivery ARO of all HARDWARE. 4. If you are a reseller/distributor you MUST disclose the manufacturer of ALL ITEMS listed. 5. If you are a reseller/distributor you MUST provide certification that Night Vision Components and Tubes are NOT Russian made. 6. You MUST reference the FMS case designator on your formal solicitations. 7. Tube data sheets will be requested after contract award 8. There will be a potential call for an incoming inspection by DCMA to check tubes and tube housings 9. A quality system on tubes and tube housings will be requested after contract award. Respond to My Attention by 11 AM Eastern on 24 November 2010 Ritsa.Karakanas@us.army.mil OR John.Padre@us.army.mil US Army C-E LCMC Acquisition Center - DAAB07 US Army C-E LCMC Acquisition Center - DAAB07 ATTN: AMSEL-AC, Building 1208 Fort Monmouth NJ 07703-5008 US
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/81fbcdbffefb89334a9382cefd1a1609)
- Place of Performance
- Address: CECOM Contracting Center (CECOM-CC) ATTN: AMSEL-AC, Building 1208 Fort Monmouth NJ
- Zip Code: 07703-5008
- Zip Code: 07703-5008
- Record
- SN02329242-W 20101119/101117234438-81fbcdbffefb89334a9382cefd1a1609 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |