Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 19, 2010 FBO #3282
SOURCES SOUGHT

58 -- FMS Case IS-B-ZUF (Israel) Night Vision System

Notice Date
11/17/2010
 
Notice Type
Sources Sought
 
Contracting Office
CECOM Contracting Center (CECOM-CC), ATTN: AMSEL-AC, Building 1208, Fort Monmouth, NJ 07703-5008
 
ZIP Code
07703-5008
 
Solicitation Number
MARKET-SURVEY-4980-1
 
Response Due
11/24/2010
 
Archive Date
1/23/2011
 
Point of Contact
Harold Schwake, 000-000-0000
 
E-Mail Address
CECOM Contracting Center (CECOM-CC)
(harold.schwake@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
FOR MORE INFORMATION CONTACT:Ritsa Karakanas 732-532-8603 OR John Padre 732-532-8630 Ritsa Karakanas, EMAIL Ritsa.Karakanas@us.army.mil OR John Padre, EMAIL john.padre@us.army.mil **You must respond NO LATER than the Respond Date and Time The US ARMY CECOM LCMC intends to acquire the following: 1,435 each commercial export Image Intensifier Tubes GEN III NTE 1600 FOM Salient Characteristics: Resolution: 64 lp/mm Signal to Noise Ratio (minimum): 21 High-Light Resolution @ 20 fc (minimum): 12 Photocathode Sensitivity (Minimum) @2856: K, A/lm: 1800 @880 nm, mA/W: 80 Halo, mm (minimum): 0.85 EBI, X10^-11 lm/cm^2 (Maximum) 2.5 Luminous Gain, fL/fc @2X10^-6 fc: 40000-7000 @2X10^-4 fc: 10000 Output Brightness, fL@1 and 20 Fc: 2.0-4.0 Output Brightness, Uniformity (Maximum) @2856K and @880 nm: 3.1 MTF (Minimum) @2.5 lp/mm: 92% @7.5 lp/mm: 80% @15.0 lp/mm: 61% @25.0 lp/mm: 38% Maximum Spots Allowed in Each Zone: Zone Spot Size (in.): 1 2 3 greater than.012 or Larger: 0 0 0 greater than.009.012:0 0 0 greater than.006.009:0 1 1 greater than.003.006:0 2 2 Information/Requirements: 1. Figure of Merit must not exceed 1600 FoM, Resolution must be 64 lp/mm and minimum Signal to Noise Ratio is 21 2. If you are a reseller/distributor you MUST disclose the manufacturer of the Tubes. 3. You MUST state delivery ARO of all HARDWARE. 4. If you are a reseller/distributor you MUST disclose the manufacturer of ALL ITEMS listed. 5. If you are a reseller/distributor you MUST provide certification that Night Vision Components and Tubes are NOT Russian made. 6. You MUST reference the FMS case designator on your formal solicitations. 7. Tube data sheets will be requested after contract award 8. There will be a potential call for an incoming inspection by DCMA to check tubes and tube housings 9. A quality system on tubes and tube housings will be requested after contract award. Respond to My Attention by 11 AM Eastern on 24 November 2010 Ritsa.Karakanas@us.army.mil OR John.Padre@us.army.mil US Army C-E LCMC Acquisition Center - DAAB07 US Army C-E LCMC Acquisition Center - DAAB07 ATTN: AMSEL-AC, Building 1208 Fort Monmouth NJ 07703-5008 US
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/81fbcdbffefb89334a9382cefd1a1609)
 
Place of Performance
Address: CECOM Contracting Center (CECOM-CC) ATTN: AMSEL-AC, Building 1208 Fort Monmouth NJ
Zip Code: 07703-5008
 
Record
SN02329242-W 20101119/101117234438-81fbcdbffefb89334a9382cefd1a1609 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.