Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 23, 2010 FBO #3316
DOCUMENT

65 -- INTENT TO SOLE SOURCE GENEXPERT 48 INFINITY SYSTEM FOR UPGRADE OF AUTOMATED MOLECULAR PCR EQUIPMENT - Attachment

Notice Date
12/21/2010
 
Notice Type
Attachment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
 
ZIP Code
10468-3904
 
Solicitation Number
VA24311RI0081
 
Archive Date
1/20/2011
 
Point of Contact
Nicole Howerton
 
E-Mail Address
e
 
Small Business Set-Aside
N/A
 
Description
THIS IS NOT A REQUEST FOR COMPETITIVE QUOTES. THIS IS A NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT. The VA New Jersey Health Care System intends to solicit and negotiate a sole source procurement with CEPHEID, INC to provide and install a GeneXpert Infinity, 48-24 System via a Cost-Per-Test (CPT)/Cost-Per-Reportable Result (CPRR) acquisition. This procurement is being conducted in accordance with FAR 6.302-1(a)(2), Only one responsible source and no other services will satisfy this requirement. This is a sources sought to determine the availability of potential sources having the skills and capabilities necessary to perform/provide the SPECIFIED BRAND NAME OR EQUIVALENT EQUIPMENT. The Pathology and Laboratory Medicine Service at Veterans Administration New Jersey Health Care System (VA New Jersey) is currently using Molecular Diagnostic equipment and technology in the nationwide VA effort to eradicate MRSA from our healthcare network. We perform this MRSA testing using the GeneXpert-16 System manufactured and distributed by Cepheid. Cepheid Inc. has exclusive rights for manufacturing and distributing our current GeneXpert System ®, GeneXpert cartridges & diagnostic software for use with the Cepheid Invitro Diagnostic Xpert cartridges for the performance of a number of tests including MRSA. We are now seeking to upgrade to a compatible, commercially available system to continue performing MRSA testing and to expand our test menu to include (but not limited to): GBS, EV, C.diff, MRSA/SA Skin and Soft Tissue (SSTI), MRSA/SA Blood Culture (BC), and H1N1. Additionally, the test menu should preferably be broad and include molecular testing for non-neoplastic and neoplastic conditions such as cancers (BCR-ABL, JAK2, etc.), blood disorders (Factor II/Factor V mutations, etc.), and other infectious diseases (VRE, drug-resistance tuberculosis, and MRSA/SA Nares). The GeneXpert Infinity48-24 System has the following advantages and features: "The high through-put, molecular diagnostic system that can produce more than 1,300 different test results per day. "Robotic cartridge handling, managed by Cepheid's Xpertise software. "Continuous sample processing operation mode allows true 24/7 results. "Random access capability - different assay protocols can be run at the same time or may be started at different times and run at the same time. "The fully integrated sample extraction process and automated real-time PCR system contribute to ease of use, productivity, reproducibility and reduced turn-around-time. "Simplicity and ease of use for true deploy ability and sustainability. oOnly five (5) manual steps to introduce specimen into instrument. oManual steps take a total of approximately 2 minutes per sample. oManual steps can be conducted by any trained staff-member - not limited to highly-trained/skilled employees. oNo precision pipetting steps. oSimple enough to be operated during any shift and report results. "Batching is not required to achieve either operational efficiency or cost savings. "Each assay contains sample processing control, internal control, and probe check control - external controls are not required. Does not require separately processed controls with each run. "Results in less than 58 minutes. "Closed System - reduces potential for amplicon contamination. "No special lab requirements for PCR setup and testing. "Utilizes primarily lyophilized reagent technology vs. liquid reagents - contributes to ease of use, reagent stability, and reproducibility. The proposed period of the contract will be for a base year + 4 option years. NAICS Code 334516 Analytical Laboratory Instrument Manufacturing applies to this procurement. The VA intends to procure this requirement on a sole source basis in accordance with the statutory authority of 41 U.S.C. 253(c) (1) as implemented by FAR 6.302-1. Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub-zone, 8(a), small, small disadvantage, woman-owned small business, or large business) relative to NAICS 334516, Analytical Laboratory Instrument Manufacturing (size standard 500 employees). Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES and no solicitation will be issued; however, any firm that believes CEPHEID is not the only source for this requirement may notify the Contracting Officer by email no later than 5 PM Tuesday, December 28, 2010. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the requirement listed. Responses can be sent by email to Nicole.Howerton@va.gov. Determination by the Government not to compete this proposed contract based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. Telephone or faxed inquiries will not be accepted. If no responses are received, the VA Medical Center will proceed with a sole source negotiation with CEPHEID.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/VA24311RI0081/listing.html)
 
Document(s)
Attachment
 
File Name: VA-243-11-RI-0081 VA-243-11-RI-0081 CEPHEID SOLE SOURCE.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=167890&FileName=VA-243-11-RI-0081-000.doc)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=167890&FileName=VA-243-11-RI-0081-000.doc

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02347998-W 20101223/101221234010-c8a5908d3328a5a0aa54a1be4e56ee86 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.