SOURCES SOUGHT

J -- Dockside repairs USCGC Valiant (WMEC-621)

Notice Date
1/6/2011
 
Notice Type
Sources Sought
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC) Procurement Branch 1, 300 East Main Street, Suite 600, Norfolk, Virginia, 23510-9102, United States
 
ZIP Code
23510-9102
 
Solicitation Number
HSCG80-11-Q-P45009ss
 
Archive Date
1/6/2012
 
Point of Contact
Beverly A Garner, Phone: (757) 628-4663, Fredrick B Baechle, Phone: 757-628-4652
 
E-Mail Address
Beverly.A.Garner@uscg.mil, frederick.b.baechle@uscg.mil
(Beverly.A.Garner@uscg.mil, frederick.b.baechle@uscg.mil)
 
Small Business Set-Aside
N/A
 
Description
The United States Coast Guard is considering whether or not to set aside an acquisition for HUBZone concerns, for Service-Disabled Veteran-Owned Small Business Concerns (SDVOSB) or for Small Business. The NAICS Code is 336611. The small business size standard is less than 1,000 employees. The acquisition is for DOCKSIDE repairs to the USCGC VALIANT (WMEC-621), a 210 FOOT B CLASS MEDIUM ENDURANCE CUTTER. The vessel is home ported in MIAMI BEACH, FL. The contractor shall perform all work at the cutters homeport. The performance period will be forty-three (43) calendar days with a start date on or about May 31, 2011. The scope of the acquisition is for the overhauling, cleaning and repairing of various items aboard the USCGC Valiant (WMEC-621). This work will include, but is not limited to: (1-D) Main Diesel Engine (MDE) exhaust stack uptakes, clean (2-D) Ship Service Diesel Generator (SSDG) exhaust piping, clean (3-D) Boiler Exhaust stack uptakes, clean (4-D) Rails (Handrail and/or stanchions)), renew (5-D) Fan Coil units, renew (6-D) Ventilation ducting, renew (7-D) Fuel piping, renew (8-D) TALON helicopter landing grid, perform inspection and maintenance (9-O) Perform ultrasonic thickness measurements - steel plating (50 shots) (10-D) Warping Capstan-Maintenance (11-D) Port bridge wing deck, inspect (12-D) Gun mount, renew pedestal (13-D) Structural Plating-deck plating (steel, frame 164) renew (14-D) Structural Plating-shell plating (steel, frame 205) renew (15-D) Structural Plating-shell plating (steel, frame 210) renew (16-D) Piping insulation, renew (17-D) Steam piping, renew (18-D) Structural Plating-LOG office deck plating (steel) renew (19-D) Polymeric Epoxy Resin Deck Covering, renew, Engineering LOG office (A-O) Composite Labor Rate (B-D) GFP Report (C-D) Travel and Per diem All welding and brazing shall be accomplished by trained welders who have been certified by the applicable regulatory code performance qualification procedures. At the present time, this acquisition is expected to be issued Full and Open with no set aside. However, in accordance with FAR 19.1305, if your firm is HUBZone certified or 19.1404 if you firm is SDVOSB or 19.501 if your firm is a Small Business and intends to submit an offer on this acquisition, please respond by e-mail to beverly.a.garner@uscg.mil or by fax (757) 628-4562. Questions may be referred to Beverly Garner at (757) 628-4663. In response please include the following: (a) a positive statement of your intent to submit a bid for this solicitation as a prime contractor; (b) evidence of experience in work similar in type and scope to include contract numbers, project titles, dollar amounts, points of contact and telephone numbers; (c) past performance references with points of contact and phone numbers. At least two (2) references are requested, but more are desirable. Contractors are reminded that should this acquisition become a HUBZone set aside, SDVOSB Small Business or Small Business set aside, FAR 52.219-3, Notice of Total HUBZone Set-Aside or 52.219-27, Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside or 52.214-6, Notice of Total Small Business Set-Aside, will apply, which requires that at least fifty (50) percent of the cost of personnel for contract performance be spent for employees of the concern or employees of other HUBZone small business concerns. Your response is required by 27 JANUARY 2011 at 2:00 PM EST. All of the above must be submitted in sufficient detail for a decision to be made on a HUBZone, Service-Disabled Veteran-owned Small Business set aside or Small Business set aside. Failure to submit all information requested may result in a small business set-aside. A decision on whether this will be pursued as a HUBZone or SDVOSB small business set aside, or a Small Business set aside, will be posted on the FedBizOps website at http://www.fedbizopps.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/COUSCGMLCA/HSCG80-11-Q-P45009ss/listing.html)
 
Place of Performance
Address: 100 MacArthur Causeway, Miami Beach, Florida, 33139, United States
Zip Code: 33139
 
Record
SN02355580-W 20110108/110106234242-d2f50443d35b44172a1f09474f046b54 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |