H -- Inspect, Test, Maintenance, Calibration, and Single line drawings of electrical power distribution system - Attachment
- Notice Date
- 12/1/2011
- Notice Type
- Attachment
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- Department of Veterans Affairs;Rocky Mountain Network;NCO 19 Contracting;4100 E. Mississippi Avenue, Suite 1110;Glendale CO 80246
- ZIP Code
- 80246
- Solicitation Number
- VA25912Q0007
- Response Due
- 12/27/2011
- Archive Date
- 2/25/2012
- Point of Contact
- Glenn Breitling
- E-Mail Address
-
2-1565
- Small Business Set-Aside
- N/A
- Description
- The Grand Junction VA Medical Center, 2121 North Avenue, Grand Junction, CO 81501 has a requirement for inspection, testing, maintenance and/or calibration, single-line drawings (Auto-CAD) of facility electrical power distribution system, Infra-red scan of system, Ultrasound scan of selected switchgear and a consolidated report for the Electrical Power Distribution System and all its components at the medical facility complex, approximately 271,000 square feet. The period of performance and work shall be performed during a one to two week period during the cooler months and prior to March 31, 2012, mutually agreed to at least 30 days in advance by the contractor and VA PTL General Foreman with most work anticipated to be performed nights and weekends. Times for all electrical outages will be scheduled by the PTL General Foreman. A set of drawings is available upon request by the prospective offeror. The drawings reflect the overall layout and magnitude of the system as installed, but are not completely accurate due to subsequent construction changes. A facility walk through will be conducted on a scheduled date after posting of the solicitation and before offers are due. Electrical Systems and Equipment to be inspected, tested and preventive maintenance accomplished for are defined as: (1) All energized VA-owned electrical distribution systems from Grand Junction Public Service Company (EXCEL Energy), service through and including all main low voltage circuit breakers and all other circuit breakers installed in the switchgear located throughout the medical center areas. (2) The emergency power electrical distribution system from switchgear and components installed in the emergency generator rooms (North, South Bldg 1, Building 33 (ITS), Bldg 36, and Boiler Plant), downstream to all automatic transfer switches (ATS ™s).
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/SLCVAMC660/SLCVAMC660/VA25912Q0007/listing.html)
- Document(s)
- Attachment
- File Name: VA-259-12-Q-0007 VA-259-12-Q-0007_1.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=278234&FileName=VA-259-12-Q-0007-000.doc)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=278234&FileName=VA-259-12-Q-0007-000.doc
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA-259-12-Q-0007 VA-259-12-Q-0007_1.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=278234&FileName=VA-259-12-Q-0007-000.doc)
- Place of Performance
- Address: Grand Junction VA Medical Center;2121 North Ave;Grand Junction, CO
- Zip Code: 81501-6428
- Zip Code: 81501-6428
- Record
- SN02631539-W 20111203/111201234454-b6af2f692b238d71f29a211e2abba7dd (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |