Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 09, 2012 FBO #3729
DOCUMENT

Y -- Replace 400 Ton Chiller and Piping - Attachment

Notice Date
2/7/2012
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;VA Medical & Regional Office Center;2501 W. 22nd St.;Sioux Falls SD 57105
 
ZIP Code
57105
 
Solicitation Number
VA26312B0184
 
Response Due
3/13/2012
 
Archive Date
6/11/2012
 
Point of Contact
Kelly Nussbaum
 
E-Mail Address
6-3230
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Project Description: Provide all materials, labor, parts, and equipment necessary to complete project 438-12-110 "Replace 400 Ton Chiller and Piping", in accordance with the plans and specifications. This project is located at the Sioux Falls, SD VA Medical Center and relates to the main chilled water system for the hospital (Building 5). This project primarily consists of replacing one (1) 400 ton chiller (5-CCU1) and reconfiguring the chilled water piping in accordance with plans and specifications. In addition to the plans and specifications the contractor shall provide the following: 1)Sandblast all cooling tower structural steel and apply three (3) paint coats. All Contractors and Subcontractors that perform the surface preparation and coating application shall be certified NACE Level 2. Sandblasting procedure and coating application shall be submitted and approved by the COR prior to any work completed. a.Primer Coat = Zinc-Rich Epoxy Primer Coat, MIL-DTL-24441-19 b.Epoxy intermediate Coat = MIL-DTL-24441-31 c.Polyurethane Topcoat = MIL-PRF-85258 2)Remove and replace the existing aggregate base under the cooling tower, replace with 2" typical river rock and install thirty (30) each 15"-24" square precast concrete stepping stones in various locations around the cooling tower. Materials and stone location shall be submitted to the COR for approval prior to any work completed. 3)Replace and provide four (4) existing wall pack lights that are mounted exterior of the chiller plant with Cooper Lighting (LD-WP-GL-4A-MT-PE) or approved equal. Voltage shall be verified prior to shop drawing submittal. 4)Overhaul the YORK Chiller (5-CCU3) located on the west end of the chiller plant per the manufactures 30,000 hour recommendation this shall include: "Labor for compressor inspection (disassembly and reassembly) "New gasket kit and necessary individual gaskets "Suction Elbow Gaskets "New Bellows Style Shaft Seal oNew oil, filters and driers oLeak Check, evaluate and re-install refrigerant oStart up and check operation The Project duration is expected to be 320 days from the date of receipt of the notice to proceed. Completion must occur before the cooling season, end date cannot exceed 4/30/2013. Electronic solicitation documents will be made available in electronic format only through the VA website at: http://www.fedbizopps.gov. It is recommended that you complete the solicitation mailing list on the website before downloading the solicitation. This procurement is 100% set-aside for SERVICE DISABLED VETERAN OWNED SMALL BUSINESS (SDVOSB). Prospective contractors must be registered and current in the following websites prior to award: http://www.vip.vetbiz.gov, http://www.ccr.gov; and https://orca.bpn.gov to be eligible for award. Bids will only be accepted from responsible and responsive contractors The firm must be a General Construction firm approved under NAICS code 238220-size standard is $14.0 million. Bid Bond will be required in the amount of 20% of bid, and Performance and Payment bonds will be required upon award of contract. The estimated dollar value of this procurement is between $500,000 and $1,000,000.00. Specifications and drawings will be uploaded on or about February 13, 2012. Specs and plans will be available for download from the fedbizopps site. http://fbo.gov Amendments to this solicitation will be posted at the fedbizopps website. In order to receive e-mail notification of amendments, you must register in fedbizopps to Receive Notification of amendments. Bidders are responsible for obtaining and acknowledging all amendments to this solicitation prior to the time of proposal submittal. Fax and e-mail questions concerning drawing or specification should be sent to Kelly Nussbaum, FAX 605-333-6829 or Kelly.Nussbaum@va.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/SFaVAMC/VAMCCO80220/VA26312B0184/listing.html)
 
Document(s)
Attachment
 
File Name: VA263-12-B-0184 VA263-12-B-0184_1.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=294624&FileName=VA263-12-B-0184-000.doc)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=294624&FileName=VA263-12-B-0184-000.doc

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;2501 W. 22nd St.;Sioux Falls SD 57105
Zip Code: 57105
 
Record
SN02669260-W 20120209/120207235143-b345a3cf432577c3bdff0f2ee6962908 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.