DOCUMENT
46 -- Water Purification System for Dialysis - 510K registered compliant medical device - Attachment
- Notice Date
- 2/21/2012
- Notice Type
- Attachment
- NAICS
- 332420
— Metal Tank (Heavy Gauge) Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 8;Commerce Building;300 E. University Ave. Ste. 170;Gainesville FL 32601-3460
- ZIP Code
- 32601-3460
- Solicitation Number
- VA24812I0940
- Response Due
- 2/24/2012
- Archive Date
- 3/25/2012
- Point of Contact
- Joseph Boudreau
- E-Mail Address
-
Contract Specialist
(JOSEPH.BOUDREAU@VA.GOV)
- Small Business Set-Aside
- N/A
- Description
- Market Research for Water Purification for the Dialysis Clinic at the Malcolm Randall VA Medical Center in Gainesville, Florida. This is a Sources Sought Notice only. This does not constitute a solicitation. The information gathered from this request for information (RFI) is for planning purposes only. The Government is not obligated, nor shall it pay for, any information received from potential sources as a result of this Sources Sought Notice. The purpose of this notice is to identify mandatory sources of supply as required by FAR 8.002 and small business entities capable of providing 510K compliant registered water purification system for the Dialysis Clinic as follows: Dialysis Water Purification Statement of Work 1.Introduction The Malcolm Randall VAMC in Gainesville, FL is currently in need of a new water purification system as part of the hemodialysis treatment center. 2.Requirements The Malcolm Randall VAMC in Gainesville, FL is seeking a turnkey water purification to be installed by the awarded contractor. The following parameters shall be considered by prospective vendors: -Multi-Media Filter for turbidity reduction -Activated Carbon filter for Chlorine, Chloramine Reduction -Water Softener for Hardness reduction -Reverse Osmosis System for reduction of TDS and Organics - Water purification system must be FDA 510k compliant registered medical device - AAMI Feed water analysis -AAMI Reverse Osmosis Product water analysis -RO Permeable Water Transfer Pumps - Service Exchange Service Deionization Tanks - RO Permeable Water Storage Tank Components to allow continuous operation of equipment -Control components for Mixed Beds SDI Tanks to ensure greater than 1Meg OHM water is exiting the MB tanks -Main Control Panel to be installed at Nurse's station - Final Filter Components for endotoxin removal - System installation is required. The North American Industry Classification System (NAICS) identifier for this service is Federal Supply Holders, 8(a) business, Small business, veteran-owned small business, service-disabled veteran- owned small business, HUBZone small business, small disadvantaged business, and women- owned small business concerns may respond by submitting a qualifications letter stating the following information: 1.Name 2.Capability Statement (include exact items stated in this notice) 3.DUNS # 4.Type of Business (i.e., SDVOSB, VOSB, WOSB, ETC ¦) Responses shall be sent via mail or email, no later than 4 p.m. EST on February 24, 2012. Telephone and facsimile responses will not be considered. Please send responses to: Department of Veterans Affairs, Network Contracting Office 8, Attn: Joseph Boudreau, 300 E. University Avenue, Suite 170, Gainesville, FL, 32601. Email responses shall be sent to: joseph.boudreau@va.gov.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANFSGHS/DVANoFSoGHS/VA24812I0940/listing.html)
- Document(s)
- Attachment
- File Name: VA248-12-I-0940 VA248-12-I-0940_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=299030&FileName=VA248-12-I-0940-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=299030&FileName=VA248-12-I-0940-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA248-12-I-0940 VA248-12-I-0940_2.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=299030&FileName=VA248-12-I-0940-000.docx)
- Place of Performance
- Address: 1601 SW Archer Road;Gainesville, FL
- Zip Code: 32608
- Zip Code: 32608
- Record
- SN02679203-W 20120223/120221234337-714bf5cdcfe7fa6ab16da7ce3428d22f (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |