SOURCES SOUGHT
59 -- Market Survey Request for a Power Inverter for computer related equipment in a Tactical Shelter.
- Notice Date
- 4/3/2012
- Notice Type
- Sources Sought
- Contracting Office
- ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
- ZIP Code
- 21005-1846
- Solicitation Number
- MARKET-SURVEY-5260-1
- Response Due
- 4/17/2012
- Archive Date
- 6/16/2012
- Point of Contact
- Tineka C. Davis, 443-861-5438
- E-Mail Address
-
ACC-APG - Aberdeen Division B
(tineka.c.davis.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- FOR ALL INFORMATION PLEASE CONTACT: Joseph M. Fellner, PRD Engineer, 443-395-6395 joseph.m.fellner.civ@mail.mil Sources sought for ruggedized, COTS series inverter for military applications. The device is a self contained unit that coverts DC voltage into 115VAC with an output rating of 8.7A continuous or 13A peak. NSN:6130-01-562-7680 P/N:IPSK-20-110-NG1, AC/DC Inverter, Power Static 1000W Dimensions 13in L x 9.0 in W x 7.8 in H (33.02cm L x 22.86 cm W x 19.81cm H) Weight: 30 lb (13.61 kg) Operating voltage +12 VDC Output voltage: 115VAC ( 5 V rms) Output current: 8.7A(continuous)/13 A peak Output frequency: 60 Hz ( 0.01Hz) Operating temperature: -13 F to +104 F (-25 C to +40 C) PCB's protected against condensation Meet EMC radiated and conducted emissions MIL-STD 461E On/Off switch located on front of the inverter Military connectors on front of the inverter Currently, said parts are installed in AN-TSQ-232 shelter provided by Northrop Grumman Corp (NGC) as the original developer and integrator of the shelter. The parts are currently procured by Tecknowledgey, Inc and Power Analytic Systems is the manufacturer with the possibility of a second manufacturer. The Government did not purchase and cannot provide drawing packages for these parts. As part of this acquisition effort, the items will be required to meet the same form, fit, and function of the original components to ensure the spares achieve the required performance within the communication subsystem. Contractors capable of providing the above described spares can respond to the government via email at the address shown below. The response must include documentation showing that the contractor is capable of providing the required components deliverable within 90 days of receipt of order. Successful supplier may be required to warrant the items will satisfactorily perform when used for the purposes intended by the Army. For more information please contact Joseph Fellner at (443) 395-6395 or Let Chin at (443) 395-6378.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/d4ace836c276c3649b80cbbb4c3cb9ac)
- Place of Performance
- Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
- Zip Code: 21005-1846
- Zip Code: 21005-1846
- Record
- SN02712949-W 20120405/120403235916-d4ace836c276c3649b80cbbb4c3cb9ac (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |