Z -- Replace Computer Room AC Unit - Attachment

Notice Date
4/20/2012
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;VAMC White River Junction;215 North Main Street;White River Junction VT 05009
 
ZIP Code
05009
 
Solicitation Number
VA24112R0644
 
Archive Date
6/19/2012
 
Point of Contact
Michael E Ouellette
 
E-Mail Address
6-6315<br
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Removal of a 3 Ton Computer Room AC (CRAC) unit and remote condenser, replacement with a new 12 Ton CRAC utilizing the Liebert DS Series, GLYCOOL Coil CRAC as the basis of specification. Unit to be installed in the B1 Server Room and adjacent rooftop mechanical platform at White River Junction VA Medical Center Provide all labor, equipment and material, to complete the following: "Removal and disposal of existing 3 Ton Computer Room AC unit and remote condenser. Including removal of the existing electrical feed (cable, conduit, wire mold, back to source panel "P2" in room 265-1. Patch all holes and walls as required. Patch dropped ceiling grid and tiles above retired unit; approximately 4ft x 10ft. "Furnish and install new raised flooring panels and support frame in the existing opening across the room from the new proposed AC unit - to contain the cold air under the floor. Cut, patch and piece to finish off the rough opening as required. Approximate area is 4 ft x 11ft. "Preparation of existing roof top mechanical platform, which may include the extension to accommodate a longer remote condenser unit. "Preparation of server room to accept new unit, which may include raised floor and ceiling grid modifications. "Installation of a 12 Ton CRAC, including new piping, electrical, interfaces with existing BAS and fire alarm system. Furnish and install new 480 Volt power supply from panel "P3B"; in room 336-1. "Integration of existing Liebert unit with existing BAS for full control and monitoring.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/WRJVAMROC/DVAMROC/VA24112R0644/listing.html)
 
Document(s)
Attachment
 
File Name: VA241-12-R-0644 VA241-12-R-0644 AC COMP ROOM.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=326055&FileName=VA241-12-R-0644-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=326055&FileName=VA241-12-R-0644-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02727821-W 20120422/120420235545-7c3f02ade6109ba83fb22e1d4ad78098 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.