Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 02, 2012 FBO #3843
SOLICITATION NOTICE

56 -- RECTANGULAR, PRE-CAST, CONCRETE CULVERTS

Notice Date
5/31/2012
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
327390 — Other Concrete Product Manufacturing
 
Contracting Office
ACC - McAlester Contracting Office (ACC-RI-McAlester), Attn: CCRC-IDM
 
ZIP Code
00000
 
Solicitation Number
W44W9M12T0056
 
Response Due
6/11/2012
 
Archive Date
8/10/2012
 
Point of Contact
Kent Hackett, 9184206177
 
E-Mail Address
ACC - McAlester Contracting Office (ACC-RI-McAlester)
(kent.w.hackett.civ@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. 40 EACH, RECTANGULAR, PRE-CAST, REINFORCED, CONCRETE CULVERTS, INTERIOR WIDTH 10 FT, INTERIOR HEIGHT 8 FT, EXTERIOR WIDTH 11.667 FT, EXTERIOR HEIGHT 9.667 FT., LENGTH 4 FT. EACH SECTION WILL HAVE A MALE AND A FEMALE END AND SHALL BE RATED TO WITHSTAND A COOPER E-80 RAIL LOAD WITH 5 FT. OF COVER. 10 EACH, RECTANGULAR, PRE-CAST, REINFORCED, CONCRETE CULVERTS, INTERIOR WIDTH 10 FT, INTERIOR HEIGHT 8 FT, EXTERIOR WIDTH 11.667 FT, EXTERIOR HEIGHT 9.667 FT., LENGTH 4 FT. EACH SECTION WILL HAVE A MALE AND A FEMALE END AND SHALL BE RATED TO WITHSTAND A COOPER E-80 RAIL LOAD WITH 5 FT OF COVER. AT THE FEMALE END, THE MANUFACTURER SHALL EXPOSE AN ADEQUATE AMOUNT OF REINFORCEMENT STEEL TO DEVELOP THE REINFORCEMENT WITH THE CULVERT. STEEL WILL BE TIED INTO HEADWALL, WINGWALL AND FOOTING FLOOR. 10 EACH, RECTANGULAR, PRE-CAST, REINFORCED, CONCRETE CULVERTS, INTERIOR WIDTH 10 FT, INTERIOR HEIGHT 8 FT, EXTERIOR WIDTH 11.667 FT, EXTERIOR HEIGHT 9.667 FT., LENGTH 4 FT. EACH SECTION WILL HAVE A MALE AND A FEMALE END AND SHALL BE RATED TO WITHSTAND A COOPER E-80 RAIL LOAD WITH 5 FT OF COVER. AT THE MALE END, THE MANUFACTURER SHALL EXPOSE AN ADEQUATE AMOUNT OF REINFORCEMENT STEEL TO DEVELOP THE REINFORCEMENT WITH THE CULVERT. STEEL WILL BE TIED INTO HEADWALL, WINGWALL AND FOOTING FLOOR.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/12f41734cc152b9fcee830bbec3ff707)
 
Place of Performance
Address: ACC - McAlester Contracting Office (ACC-RI-McAlester) Attn: CCRC-IDM, 1 C Tree Road McAlester OK
Zip Code: 74501-9002
 
Record
SN02762257-W 20120602/120531235402-12f41734cc152b9fcee830bbec3ff707 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.