SOLICITATION NOTICE
Z -- Fire Protection Upgrades
- Notice Date
- 7/10/2012
- Notice Type
- Presolicitation
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- N40085 NAVFAC MID-ATLANTIC, ROICC PORTSMOUTH Building 59 Code 495 Portsmouth Naval Shipyard Portsmouth, NH
- ZIP Code
- 00000
- Solicitation Number
- N4008512R4904
- Response Due
- 8/9/2012
- Archive Date
- 10/5/2091
- Point of Contact
- Allison D. Tibbetts 207-259-8242 Joanne Facteau
- E-Mail Address
-
<!--
- Small Business Set-Aside
- Total Small Business
- Description
- The project includes installation of new fire alarm systems and modifications to existing fire alarm systems at the Naval Computer and Telecommunications Area Master Station Atlantic Detachment Cutler, Maine as follows: The work includes the provision of new fire alarm systems and modifications of existing fire alarm systems in the buildings at the Very Low Frequency area, High Frequency Area and the Fire Station; provision of fire suppression systems at the Power Plant (Bldg. 103), Riggers Storage Building (Bldg. 134), High Frequency Generator Building (Bldg. 401) and the Fire Station (Bldg. 503); provision of a seawater pumping system on the pier and renovations to the existing seawater tank; replacement of fire hydrants at the tank farm; and miscellaneous associated work; the provision of all work for removal of the existing 8-inch ductile iron water supply piping and appurtenance around the fuel oil tank farm including where pipe exists at Building 123. Installation of new 8-inch ductile iron water supply piping and appurtenances in the same trench as the pip removed; including the repair of the grounding grid system in the location of the pipe trench. Removal and installation of the new fire hydrants around the tank farm shall be included in the base bid; provision of all work for removal of the existing railings on the pier from the shore to cell #6, and the installation of new railings from the shore to cell #6 on the eastern side and across the pier at cell #6 to the concrete wall on the western side. Include the disposal of the existing railing at an offsite facility and the painting of the railing; provision of all work for including the removal and disposal of the 8-inch and 10-inch diameter steel fuel oil lines from cell #6 to Building 121. The line shall be cleaned of all oily waste prior to removal; provision of all work for including the removal of the two existing 14-inch diameter ductile iron seawater lines on the pier from cell #6 to the piping vault adjacent to Building 121 and installation of the new 2-inch diameter insulated seawater pipe on the concrete wall on the west side of the pier. Existing concrete pipe supports will remain.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62472NH/N4008512R4904/listing.html)
- Place of Performance
- Address: NCTAMSLANTDET Cutler
- Zip Code: 175 Ridge Road, Cutler, ME
- Zip Code: 175 Ridge Road, Cutler, ME
- Record
- SN02798410-W 20120712/120710235553-114fa3f5af25f3c925c6cd1e7d997260 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |