SOLICITATION NOTICE
23 -- AMBULANCES
- Notice Date
- 7/11/2012
- Notice Type
- Presolicitation
- NAICS
- 336211
— Motor Vehicle Body Manufacturing
- Contracting Office
- Bogota Branch (PARC Americas 410th CSB), KO Directorate of Contracting, Unit 5136 US Embassy Colombia, APO, AA 34038-0008
- ZIP Code
- 34038-0008
- Solicitation Number
- W913FT12T0111
- Response Due
- 7/11/2012
- Archive Date
- 9/9/2012
- Point of Contact
- ASTRID PARDO, 5713832386
- E-Mail Address
-
Bogota Branch (PARC Americas 410th CSB)
(pardoaj@tcsc.southcom.mil)
- Small Business Set-Aside
- N/A
- Description
- SPECIFICATIONS (EN ESPANOL AL FINAL DE ESTE DOCUMENTO) AMBULANCE The contractor shall to provide an ambulance vehicle for basic supporting transport (Traslado Asistencial Basico - TAB) for land transport, mounted in a chassis of a 4x4 C/S Pick up truck or similar. The ambulance shall comply the specifications given by the handbook of minimal technical and sanitary requirements for land ambulances of the "Red Nacional de Urgencias" of the Health Ministry of Colombia and the requirements of the Instituto Colombiano de Normas Tecnicas - ICONTEC 3729 and the annex no. 1 of the resolution 1043 of april 2 of 2006. The ambulance shall be designed for hard work, it will be used in roads with not pavement. The contractor shall provide guarantee of all the equipment and supplies at least of one year. GENERAL DESIGN W913FT-12-T-0111 Page 4 of 45 The ambulance shall include an internal glass tempered division between the cabin and the patient area. The ambulance shall include sliding polarized glasses in the right side. The ambulance shall include two principal areas: the driver compartment and the patient compartment, which are totally independent between them. Those compartments shall be communicated visual and hearing between them by a communication module with a sliding windows system. COLOR The ambulance shall be painted white and shall fulfill the legal requirements for visibility and easy identification, with the logos of AMBULANCIA in the back and in reverse in the front. The ambulance shall include symbols made in reflective colors. IDENTIFICATION The identification shall be included in all the exterior sides of the bodywork, including the roof. The ambulance shall show the text "AMBULANCIA" with the plate number in the both sides and in the back side of the vehicle. The identification located in the external front of the bodywork shall be installed in reverse, in this way a driver can read it correctly when look in the rearview mirror. Also the ambulance shall include the text "TAB". The ambulance letters shall be 180mm height and 2.5mm wide. The ambulance shall be identified with the international red cross symbol, and it shall be located in the roof and each side of the vehicle. Inside the ambulance, in the patient compartment there shall be the text: "NO FUME" and "USE EL CINTURON DE SEGURIDAD" TOOL KIT The ambulance shall include a basic tool kit, including: One (1) fire extinguisher ABC, 2.26 kg (5 lb) for each of the compartments. One (1) set of Ratcheting Box Wrenches One (1) adjustable wrench One (1) reflective vest One (1) spare tire Three (3) slot screwdrivers Three (3) cross screwdrivers One (1) lug wrench One (1) set of emergency reflective signals One (1) lantern with battery One (1) set of twenty fuses of the same specifications needed by the ambulance One (1) tire jack and one (1) set for tire replacement. One (1) split joint pliers with isolated handle One (1) "palanca patecabra" Two (2) wood blocks to block tires One (1) 250 gram hammer W913FT-12-T-0111 Page 5 of 45 One (1) all purpose scissor One (1) static rope 20 meters, thick 12.7mm with traction hook One (1) jumper cable set One (1) water can with cleanliness set One (1) lam with car plug plus 15meter cable length EQUIPMENT Principal stretcher The ambulance shall include a two level stretcher, with wheels, back flip from 0 to 75 degrees with mechanical block system, flip security handrails, rectangular mattress foam high density covered with waterproof "cordoban", washable. The stretcher shall include safety belts. The stretcher shall be metallic, rigid, anticorrosive and light. Length: 2.00 meter minimum, between the protruding edges of the stretcher structure (including any handle or support element in the stretcher). 1.80 meters of this length shall be reserved for patient. Wide: 0.60 meter maximum including handrails. Wide shall be minimum 0.50 meter. Height: from the base of the sliding foot to the top of the stretcher, where the patient is situated: 0.25 meter as minimum to 1.35 meter as maximum. The stretcher shall include two positions: up and down. The stretcher shall include sliding foots and casement, and one person can handle it by his own. The stretcher can load 180 kilograms without suffer any structural damage. The location of the stretcher in the patient compartment shall be such that the head of the patient shall be oriented toward the front side of the vehicle. The upper part of the stretcher, where the patient's head is located, shall be separated of the partition at least 0.15 meter and the side part shall be separated at least 0.25 meter from the right side. Anchor system: the stretcher shall be secured with side supports and front focuser which does not allow cross or vertical important movements. The assurance system to transport shall be manual and do not allow movements when the vehicle accelerates or brakes, including crash events. The stretcher shall include three (3) seatbelts for the patient. Patient Passenger Seat In the right side shall be installed a seat for the patient escort. The length of this seat shall be 2.00 meter, and shall includes a rectangular mattress foam high density covered with waterproof "cordoban", washable. Below this chair shall be located the auxiliary stretcher and shall be fixed with seatbelts. Also in this place shall be four (4) drawers for sheets and blankets storage. Trauma Stretcher: A trauma stretcher shall be included. This shall be a stretcher spoon type made in aluminum "Dural" imported or similar with a long table. W913FT-12-T-0111 Page 6 of 45 Wheelchair: The ambulance shall include a wheelchair hand made of light metallic frame; shall be folding type with canvas, washable and easy disinfection with seatbelt; the transport packing shall be with bracket in the back compartment, without produce damages during the vehicle movement. This system shall guarantee the immobility of this element when the patient is on board. SPECIFIC SUPPLIES FOR "TAB" EQUIPMENT Roof bracket for parenteral liquids Venepuncture tourniquet Kidney bag Portable urinal Medical bedpan potty Fixed valve 11/8 to connect to the oxygen network Oxygen cylinder six (6) cubic meter in exclusive cabinet Oxygen regulator Pressure hose connection from oxygen cylinder to distribution system Flow meter with wall output, connected to the storage system Two (2) humidifiers vessels with fittings Four (4) reusable hoses for oxygen distribution Three (3) disposable masks for adult and three (3) for child One (1) portable electric sniffer with: One (1) vacuum pump, hoses, recollection vessel, 12v. One (1) manual pediatric breather with oxygen reserve and two (2) masks One (1) manual adult breather with oxygen reserve and three (3) masks One (1) Guedel Cannula Set 2,4,5 One (1) Lantern for exam with batteries and double service stethoscope. One (1) aneroid tension meter with sleeve for adult and child patients One (1) Short spinal board One (1) pneumatic immobilizer kit One (1) set of cervical collar Philadelphia small, medium and large Two (2) disposable sheets for the principal stretch provided Two (2) blankets One (1) "pinza macha rompe anillos" Biohazard supplies: gloves set, cap, mouth cover mask, boots, disposable shirt, glasses and disposable bags for dispose invectives substances Rigid suitcase with compartments for medicine cabinet One (1) set of small surgeries: One (1) scalpel handgrip, two (2) scalpel sheets, two (2) Kelly curve clips, two (2) Kelly straight clips, two (2) mosquito clips, one (1) medium dissection clip with claw, one (1) medium dissection clip without claw, one (1) needle holder, one (1) trim for material, one (1) trim for fabric, one (1) eye camp, one (1) stainless steel tray with cover to content the previous elements. One (1) childbirth set: two (2) large Rochester clips, one (1) episiotomy trim, one (1) trim for material and cord ligation. All the previous supplies and equipment shall be delivered sterilized and marked. W913FT-12-T-0111 Page 7 of 45 The contractor shall provide also the following supplies: One (1) package of ten (10) non woven disposable cover mouth. One (1) rigid case cantilever type One (1) "Guardian" system Five (5) micro drip infusion sets for "LEV" Five (5) macro drip infusion sets "LEV" One (1) protection glasses Five (5) Hartman solution bags 500 cubic centimeters (cc) each Two (2) saline solution bags Two (2) bags of dextrose in saline solution 5% x 500 cc One bottle of vinylpyrrolidone 100cc One (1) alcohol plastic bottle 250 cc One (1) bottle of surgery liquid soap 250 cc Ten (1) disposable syringes 5cc each Five (5) venipuncture catheters Five (5) disposable aspiration catheters One (1) portable screen with defibrillator One (1) sense organ equipment One (1) infusion pump One (1) cut ring One (1) glucometer One (1) pulse oximeter One (1) transport fan One (1) adult laryngoscope and three (3) cusps One (1) child laryngoscope and three (3) cusps One (1) Percutaneous transtracheal device One (1) set of endotracheal tubes for adult and for child One (1) thoracotomy equipment One (1) intubation guide Five (5) venous catheter different sizes Two (2) catheters for intraosseous infusion One (1) portable oxygen aluminum cylinder 5001 with dolly car, regulator, humidifier and masks ELECTRIC SYSTEM The ambulance shall be equipped with a power alternative system with electronic rectification and regulation, capable to produce and support 105 nominal amperes. The alternate shall fulfill the Norma Tecnica Colombiana (NTC) 1704. All the wires, switches and controls of the electric network shall support up to 25% over the nominal capacity of the circuit, during undefined time. All the installed circuits shall be protected with calibrated fuses, easy access for replacement. The fuses related with the medical equipment and connections of the patient compartment, shall be in a unique box located in the back compartment. W913FT-12-T-0111 Page 8 of 45 All the electric equipment of the ambulance shall work on 12v continues current, negative polarity to the vehicle mass. The electric power storage system of the ambulance shall include two (2) batteries which shall be 150 A/H as minimum capacity of accumulation for both. The accumulation system shall bring 12v which shall be able to support a 400A peak current and the capacity shall be enough to produce, without noticeable tension fall, 180A minimum during one (1) hour at 17 centigrade environment temperature. The batteries shall fulfill NTC 978, and the contractor shall provide at least fifteen months guarantee. The electric network shall be installed into distribution pipes "conduflex" type self-extinguishing and shall include a suppression interference system for the radio equipment in the ignition wires. The entire network shall be isolated, water protected, marked and identified in the electronic drawings of the ambulance. The ambulance shall include two independent electric circuits; the first one shall operate the vehicle and shall include two-way 12V DC Car Charger Cigar Cigarette Lighter, identified in the patient compartment. The second electric circuit shall include a 1700 watts electronic sine wave inverter, imported of 12v continuous current to 120 +/- 0.5v alternate current, 60 Hz located in the patient zone, protected and easy reach to operation and maintenance. This one shall a automatic disconnection system to be fed from a urban power network of 120v +/- 10v and 60 Hz frequency. The ambulance shall include an exterior outlet in the bodywork marked with the text 120v +/- 0.5v with a outdoor cap hinge type. It shall a 30 m cable minimum with ends adapted for feed. INTERNAL LIGHTS The ambulance shall include four (4) roof lamps with switch for automatic start when any door opens, and a central switch to start the lights when the back doors are closed from patient zone. The ambient lighting system shall bring a 200 luxes minimum main lighting, and 50 luxes maximum secondary lighting. The ambulance shall include a removable lamp that can be used away from the vehicle. EXTERNAL LIGHTS Over the vehicle roof, on the horizontal plane the contractor shall provide and install a imported American bar of six (6) LED modules over the vertical axis with flash duration 0.6/f, including red color polycarbonate domes in the intervals of wave, included into the Geneva Convention for sanitary vehicles. This light shall be seen it from minimum 200m away; also the contractor shall install two (2) American imported LED lamps in the back side of the vehicle. The direction of turn to 360 degrees under 8 degree vertical angle over and under the horizontal plane of the vehicle. W913FT-12-T-0111 Page 9 of 45 The lighting system shall include filters against interference for communication equipments. On the sides the ambulance shall include delimitation lights located in the middle related with the lengthwise axis, with two (2) flashing red lights and two (2) fixed white lights, inclined 15 degrees respect vertical axis on both sides of the vehicle. In the back part of the vehicle, on the vertex, the contractor shall install two (2) red flashing lights, that shall start on during the stops. The contractor shall install one (1) access halogen lamp over the hood of the vehicle. The contractor shall install in the left back side a red fog lamp. These lights can be turned on from the driver cabin and shall include the holder fuses for protection. ROAD WARNING SOUND SYSTEM The ambulance shall include an original made horn. The ambulance shall include an amplifier loudspeaker system 100 Watts, with electronic foghorn with three tones and horn, American type. This system can be turned on from the driver cabin and shall be commutable in the horn, hands free system and manual. This system shall be "Whelen" brand or similar. The loudspeaker system shall include a volume control. All the control advices shall be distributed in the drive control panel to be turned on by him or the escort. The sound intensity shall be 120 db minimum tested to 30m away from the ambulance. COMMUNICATIONS' SYSTEM The contractor shall install one (1) radiotelephone to guarantee communication with headquarter of the clinic. It shall be a mobile type 12v protected with a fuse with an outlet of the battery. It shall be installed in the driver's cabin, in a visible and accessible place. The microphone shall be installed in a place where the driver and the crew of the ambulance can access it and read cardiac telemetry. The equipment shall be shock protected and direct sunshine, and shall allow selective connection to the loudspeaker system The antenna shall be flexible and adequate adjusted length, guaranteeing that the relation of the stationary waves (ROE) be less than 1.5:1. The vehicular antenna shall be 5/8 wave. It shall be installed over the lengthwise axis of the vehicle, nearest to the center of it. it shall be mounted over an artificial ground plane made with a conducted plate 0.1m x 0.1m. The wires shall be installed in the intern side of the vehicle with an accessible place for reparations. The radiotelephone shall operate into two meter wavelength and frequency opening between 135.000 and 160.000 with lateral range 12.5 MHz, 20w power minimum output transmission. It shall include minimum two (2) channels and maximum four (4) fixed and tone board. The equipment shall be capable to be programmed by software. BODYWORK The structure of the bodywork shall be manufactured with metallic cold rolled sheet 18 thick, exterior covered with aluminum sheet 2mm thick. It shall include front and back bumper, resistant to shocks and shall exceed 50mm the vertical front ends. DOORS The ambulance shall include four (4) accesses: W913FT-12-T-0111 Page 10 of 45 Two (2) in the driver cabin, one at each side of the vehicle with key bock and interior control access. Opening over vertical turn to forward and 75 degrees angle, and height 0.60m. The principal access shall be located in the back of the ambulance with two vertical sheets with key lock, handle, and interior control and fixed polarized glass on the top. It shall be a 1.10m height door and 1.20 m wide as minimum. The fourth access shall be located on the right side of the ambulance with a 0.6m wide usable opening and 1.10m height as minimum, turning over his vertical axis with a non-skid step. All the steps shall be non-skid type. The doors shall be designed to avoid accidental opening. Also with interior opening mechanism and external opening using a key. On the driver main board shall be installed the open doors signal indicator, 10mm diameter and flashing light 2Hz-4Hz frequency, and shall be marked "PUERTAS ABIEERTAS". All the doors shall be hermetic against dust, water, air and in the bottom of them shall be installed reflective red bars and shall be seen when the doors are complete opened. WINDOWS Al the windows shall fulfill the NTC 1467. The windows of the cabin doors shall open vertically. All the windows shall include security glasses in the superior third, homologated for automotive use in the patient zone, and shall be polarized with inside to outside visibility. The dimension shall 0.30m height and 0.40m length as minimum. The back door windows all be fixed with hammer tool to break them for an emergency event. There shall not be left side windows, and all the windows shall be hermetic. INTERIOR COATING The interior of the ambulance shall be covered with an washable and sterilized material without fluid or sharp elements. It shall be white polyester reinforced with fiber glass class 8, fire retardant and disinfectant 4.5mm thick. FLOOR The ambulance floor shall be metallic sheet pressed 18 gauge, with 12 gauge bridges, covered with 10mm thick triplex sheet, sheathed with non-skid material, without steps. Any level change shall be performed with a ramp 6% slope. The floor material shall cover until 50mm in relation with the floor. PATIENT COMPARTMENT It shall a seat in the head of the patient. CABINETS The contractor shall provide a resistant shocks cabinet for medical drugs, washable, without sharp edges, with sliding doors acrylic translucent made, against accidental opening system included and shelves adjustable. It shall be wall to wall and floor to roof type. The contractor shall provide and install an isolated cabinet for oxygen cylinders, and it shall be centralized fixed W913FT-12-T-0111 Page 11 of 45 with visible and adjustable gauges from patient compartment. All the medical equipment shall be locked but allowing mobility. The ambulance shall include a handrail bar in the center and along of the patient compartment for the support of the care staff. ESCORT SEAT It shall be a lateral seat built over furniture for storage with hermetic mattress and washable, white color with safety belts for two persons with protection in the lateral panel for the heads of the passengers and it shall be the place for the additional stretcher with safety belt for transportation when it is in use. CREW SEAT It shall be located in the patient compartment and it is for the care stuff of the patient. This seat shall include safety belt, back support and head support. It shall be located in front of the stretcher at the top. DIMENSIONS OF THE AMBULANCE Minimum length (bumper to bumper) 4.30 meters Patient area: minimum length: 2.20 meters Minimum wide: 1.60meters Minimum height: 1.35 meters ENVIRONMENTAL CONDITIONS TEMPERATURE The equipments in the ambulance shall be storage between -5 centigrade and 45 centigrade. The ambulance shall be in temperatures between 5 centigrade and 45 centigrade during 6 hours and use the equipment when the temperature has varied between 0 centigrade and 40 centigrade. The contractor shall provide and install an Air Conditioned (A/C) System with a control in the patient compartment. This A/C shall get the maximum dry temperature of the patient compartment on 24 centigrade in 20 minutes and shall fulfill the NTC 3476. The cooling of the A/C system shall be ecologic and shall take the air from the ambulance exterior on the opposite side of the vehicle exhaust pipe. The ambulance shall include an exhaust fan12v, and the electric system of the ambulance shall support this equipment without detriment of the performance of the vehicle. NOISE LEVEL The contractor shall fulfill the standards of the Ministry of Health about soundproofing. WATERPROOF The ambulance shall comply a test of projection of water spay jet during 2 minutes and 4 meter away and 30 grades opening. The ambulance passes the test if after the 2 minutes and a complete inspection, the vehicle does not show any leakage or infiltration. W913FT-12-T-0111 Page 12 of 45 EXHAUST The ambulance shall expel the motor gases in a side of the ambulance, for a back side of the lateral doors and before the back tires. ESPECIFICACIONES EN ESPANOL Terminos de Referencia - Ambulancia El contratista suministrara un vehiculo de ambulancia, para Traslado Asistencial Basico - TAB, para transporte terrestre, montado en un chasis de una camioneta 4x4 C/S Pick up o similar. La ambulancia deber cumplir el manual de requisitos minimos, t cnicos y sanitarios para ambulancias terrestres de la Red Nacional de Urgencias del Ministerios de Salud y las exigencias establecidas en la norma Icontec 3729 y anexo No. 1 de la resoluci n 1043 del 3 de abril de 2006. La ambulancia va a ser usada en caminos terciarios, no pavimentados, as que deben ser de trabajo pesado, y deben ofrecer garant a de en todos los equipos y elementos de por lo menos un a o. DISE O GENERAL: Se instalar una divisi n con vidrio de corredera entre la cabina y la zona del paciente. Llevar vidrios de corredera polarizados al lado derecho. La ambulancia consta de dos reas principales compartimiento del conductor y compartimiento del paciente los cuales son totalmente independientes comunicadas visual y auditivamente entre si por un modulo de comunicaci n con un sistema de ventanas corredizas. COLOR: Pintura de color blanco que re ne las condiciones de visibilidad y f cil identificaci n. con los emblemas de ambulancia en la parte trasera y delantera invertido.Se aplicar n distintivos con colores reflectivos que junto con la rotulaci n permitan identificar de forma clara e inequ voca al veh culo como ambulancia. IDENTIFICACION: La identificaci n debe estar en todos los lados exteriores de la carrocer a, incluido el techo, debe llevar la leyenda de "AMBULANCIA" y el numero de identificaci n en los costados laterales y en la parte posterior de la carrocer a. La identificaci n ubicada en la parte anterior externa de la carrocer a se colocara en sentido inverso de manera que el conductor que precede la ambulancia puede leer claramente la palabra AMBULANCIA en el espejo retrovisor.Adicionalmente se debe incluir en el rotulado la sigla de identificaci n TAB.Las letras de Ambulancia, ser de 180mm de altura y de 2.5mm de espesor. La ambulancia se debe identificar con el logosimbolo internacional de la Cruz Roja, visible desde la parte de la ambulancia (vista de planta) o en el techo y puertas W913FT-12-T-0111 Page 13 of 45 posteriores de la misma. El compartimiento del paciente debe tener las leyendas "NO FUME" y "USE EL CINTURON DE SEGURIDAD". EQUIPO DE HERRAMIENTAS: -1 extintor para fuegos ABC, con capacidad m nima de 2,26kg (5 lb.) para cada uno de los compartimientos -1 juego de seis llaves -1 llave inglesa -1 chaleco fluorescente -1 rueda de repuesto -3 destornilladores de pala -3 destornilladores de estrella -1 llave de pernos tipo cruceta -se ales reflectivas de emergencia -linterna con pilas -caja de fusibles x 20 unidades de los usados por este veh culo -1 gato y (1) equipo para sustituci n de ruedas -1 alicate de mango aislado -1 palanca pate cabra -2 tacos de madera o de otro material para bloqueo de llantas -1 martillo de 250 grs. -1 tijera corta todo -1 cuerda est tica de 20 m, con un di metro m nimo de 12,7 Mm. y su correspondiente gancho de tracci n -1 juego de cables de iniciaci n para la bater a caneca de agua con elementos propios de aseo l mpara con enchufe con cable m nimo de 15m de longitud a toma corriente DOTACION: CAMILLA PRINCIPAL: camilla de dos niveles, con ruedas, espaldar abatible de 0 a 75 grados con sistema mec nico de bloqueo, barandas de seguridad a los lados abatibles, colchoneta rectangular en espuma de alta densidad de 10cm de espesor forrada en cordob n impermeable,lavable,cinturones de seguridad. Ser de material met lico, garantizando rigidez anticorrosi n y ligereza. Longitud:2 mts m nimo medido entre los puntos mas sobresalientes de la estructura incluidos los asideros y elementos adicionales de manejo y transporte. De la longitud, 1.80 mts estar n reservados al paciente. W913FT-12-T-0111 Page 14 of 45 Anchura:60cms como m ximo incluyendo barandillas y el ancho no ser menor de 50cms Altura:desde la base de los pies deslizantes a la parte superior del plano destinado al paciente 0.25 mts como m nimo a 1.35 mts como maximo.Tendra dos posiciones,alta y baja. Pies deslizantes y abatibles y ser manejable por una sola persona. La camilla ser capaz de soportar 180 Kg. sin sufrir da os en la estructura. La disposici n de la camilla en el compartimiento estar de forma tal que la cabeza del paciente este orientada hacia la parte delantera del vehiculo.La parte superior de la camilla correspondiente a la cabeza estar separada de la partici n al menos 15cms y la parte lateral estar separada al menos 25 CMS del lateral derecho. Sistema de anclaje:la camilla se asegurara con soporte lateral y enfocador delantero que no permite movimientos transversales ni verticales de importancia.El sistema de aseguramiento para transporte ser manual y no permitir movimientos en caso de aceleraciones o frenadas incluidos los casos de colisiones La camilla llevara (3) cinturones de seguridad para el paciente. ASIENTO ACOMPA ANTE: Al lado derecho se instalar un asiento para acompa ante del largo total con colchoneta abatible forrada en cordob n que ser el sitio de colocaci n de la camilla auxiliar y fijada por medio de cinturones de seguridad en la parte inferior con compartimiento para almacenamiento de sabanas y mantas. CAMILLA DE TRAUMA: Camilla tipo cuchara en aluminio dural importada Tabla larga SILLA DE RUEDAS: Construida en marco met lico ligero, plegable con tendido en lona, lavable y de f cil desinfecci n con cintur n de seguridad, empaque de transporte soporte en el compartimiento posterior,sin producir ni producirse da o durante el movimiento del vehiculo.Este garantizara la inmovilidad de este elemento cuando este el paciente a bordo. DOTACION ESPECIFICA TAB EQUIPO -Soporte para techo para l quidos parenterales -Torniquete de venopunci n -Una ri onera -Pato orinal W913FT-12-T-0111 Page 15 of 45 -Pato coprol gico -Llave boca fija de 11/8 para conexi n a la red de oxigeno -Cilindro de oxigeno de 6m3 en gabinete exclusivo -Regulador de oxigeno -Conexi n en manguera de presi n desde el cilindro hasta el sistema de distribuci n -Un flujo metro con toma pared conectado al sistema de almacenamiento -Dos vasos humidificadores con racores -Cuatro mangueras reutilizables para repartici n de oxigeno -Mascarillas desechables (3) adulto,(3) ni o -Un succionador el ctrico port til que consta de : Bomba de vac o,mangueras,vaso de recolecci n,corriente a 12v. -Un respirador manual pedi trico con reservorio de oxigeno y 2 mascaras -Un respirador manual adulto con reservorio de oxigeno y 3 mascaras -Un juego de c nulas de guedel 2,4,5 -Una linterna de examen con sus respectivas pilas -Fonendoscopio de doble servicio. -Tensiometro aneroide con mangas para pacientes adultos y pedi tricos -Una tabla corta espinal -Kit de inmovilizadores neum ticos -Juego de collares cervicales PHILADELPHIA small,m dium y large -Dos sabanas desechables con las medidas de la camilla principal. -Dos mantas -Una pinza macha rompe anillos -Material de bioseguridad:guantes,gorro,tapabocas,botas, blusa en material desechable,gafas y bolsas desechables para disposici n de las sustancias infecciosas. -Un malet n r gido,con compartimentos para botiqu n -Un equipo de peque a cirug a:(1)mango de bistur, dos hojas de bistur, dos pinzas Rochester,dos pinzas Kelly curvas.dos pinzas Kelly rectas,dos pinzas mosquito, una pinza de disecci n mediana con garra y una sin garra, un portaagujas,una tijera de material, una tijera de tejido, un campo de ojo.Una cubeta en acero inoxidable con tapa para contener lo anterior. Equipo de parto:dos pinzas Rochester largas, tijera de episiotom a, tijera de material y ligadura umbilical. Este equipo permanecer esterilizado y rotulado. -Un paquete de 10 tapabocas desechables -Un malet n r gido cantaliver -Un sistema Guardi n -Cinco equipos de microgoteo para administrar LEV -Cinco equipos de macrogoteo para administrar LEV -(1) gafas de protecci n -Cinco bolsas de soluci n de Hartman de 500cc c/u W913FT-12-T-0111 Page 16 of 45 -Dos bolsas de soluci n salina -Dos bolsas de dextrosa en soluci n salina al 5% x 500cc -Un frasco de vinilpirrolidona de 100cc -Un frasco de alcohol en pl stico de 250cc -Un frasco de jab n quir rgico -Diez jeringas desechables por 5cc c/u -Cinco cat teres de venopuncion -Cinco sondas de aspiraci n desechables -Monitor port til con desfibrilador -Equipo de rganos de los sentidos -Una bomba de infusi n -Un corta anillos -Un gluc metro -un oximetro de pulso -Un ventilador de transporte -Laringoscopio adulto y tres valvas -Laringoscopio pedi trico y tres valvas -Dispositivo trastraqueal percutaneo -Tubos endotraquiales adulto y pedi trico -Equipo de torascotomia -Una gu a de intubaci n -(5) cat teres venosos e diferentes tama os -(2) cat teres para infusi n intraosea -Bala de oxigeno port til de aluminio de 500l con carro transportador,regulador,humidificador y mascaras. SISTEMA ELECTRICO: Las ambulancias deben estar equipadas con un sistema generador tipo alternador con rectificaci n y regulaci n electr nica con capacidad de producir 105 amperios nominales. El alternador cumplir con la NTC 1704 Todos los cables, interruptores y mandos de la instalaci n el ctrica deben soportar sin deterioro m nimo hasta el 25% por encima de la capacidad nominal del circuito, por tiempo indefinido. Todos los circuitos instalados deben estar protegidos mediante fusibles calibrados de f cil accesibilidad para su eventual sustitucion.Los fusibles correspondientes al equipo medico y conexiones del compartimiento del paciente, deben ir en una caja nica en el compartimiento posterior. Todo el equipo el ctrico de la ambulancia, funcionar a una tensi n nominal de 12v de corriente continua, con polaridad negativa a la masa del veh culo. El sistema de almacenamiento de energ a el ctrica de todas las ambulancias constara de dos bater as las cuales deben tener una capacidad m nima de acumulaci n entre las dos de 150 A/H. W913FT-12-T-0111 Page 17 of 45 El sistema de acumulaci n proporcionara una tensi n de 12v capaz de suministrar una corriente pico de 400A y su capacidad debe ser suficiente para producir sin ca da apreciable de tensi n una intensidad m nima de 180A durante una hora a 17oC de temperatura ambiente.Las bater as cumplir n con todos los requisitos establecidos en la NTC 978.Se suministrar la garant a de las bater as. La instalaci n el ctrica estar dentro de tubo de distribuci n (conduflex) que es auto extinguible y poseer un sistema de supresi n de interferencia para los equipos de radio en los cables de ignicion.Estara aislada, protegida del agua, se alizada e identificada en planos electr nicos de la ambulancia. La ambulancia tendr dos circuitos el ctricos independientes el primero para operar el veh culo que adem s extender dos tomas tipo encendedor de cigarrillos bien identificados en la zona de pacientes y el segundo con un inversor de 1700 watts sinusoidal electr nico, importado de 12v de corriente continua a 120 mas o menos 0.5v de corriente alterna a 60hz ubicado en la zona de pacientes, protegido y de f cil alcance para operaci n y mantenimiento.Tendra un sistema de desconexi n autom tica al ser alimentado a la red urbana a una tensi n de 120v mas o menos 10v y frecuencia 60hz. Se instalara una toma exterior en la carrocer a marcada con entrada a 120v mas o menos 0.5v con tapa para intemperie tipo bisagra.Tendra un cable m nimo de 30 mts con extremos adaptados para alimentaci n. LUCES INTERIORES: cuatro l mparas de techo con switch de cortes a para encendido autom tico al abrir las puertas y switch central para accionar las luces cuando las puertas traseras se encuentren cerradas desde la zona del paciente. El sistema de iluminaci n ambiental proporcionara una iluminaci n principal de m nimo 200 lux y una iluminaci n secundaria m xima de 50 lux. La ambulancia llevara l mpara desmontable que permita su utilizaci n a distancia del veh culo. LUCES EXTERIORES: Sobre la capota sobre el plano horizontal se instalar una barra importada americana de seis m dulos LED sobre su eje vertical con duraci n de destello 0.6/f,con domos en poli carbonato de color rojo en los intervalos de onda acogidos en los convenios de Ginebra para veh culos sanitarios.Esta se podr ver a 200m m nimo y se instalara en la parte trasera dos l mparas LED importadas. El sentido de giro a 360 grados bajo un ngulo vertical de 8 grados por encima y debajo del plano horizontal del veh culo. Dotados con filtros contra interferencia para equipos de comunicaciones. A los lados llevara luces de delimitaci n con respecto a su eje longitudinal dos luces rojas intermitentes y dos luces blancas fijas con inclinaci n de 15 grados con respecto a su eje vertical a cada lado del vehiculo.En la parte trasera se instalar n dos l mparas W913FT-12-T-0111 Page 18 of 45 intermitentes rojas en los v rtices en caso de parada.En la parte trasera de la capota se instalar una l mpara hal gena de acceso. Se instalara al lado izquierdo trasero un faro antiniebla de color rojo.Las luces ser n accionadas desde la cabina del conductor y llevar n sus respectivos portafusiles de norma para protecci n. SISTEMA SONORO DE ALERTA VIAL: La ambulancia tendr un pito original de fabrica. Se suministrar un amplificador de perifoneo de 100 WATTS de potencia RMS,americano con sirena electr nica de tres tonos y horn,accionada desde la cabina conmutables en el pito en manos libres y forma manual marca WHELEN. El perifoneo tendr control de volumen.Los dispositivos de mando estar n en el panel de control del conductor para ser accionado por este y su acompa ante. La intensidad sonora ser m nimo de 120db medidos a 30 mts del veh culo. SISTEMA DE COMUNICACIONES Se instalara un radiotel fono para tener contacto con la base de tipo m vil a 12v protegido por fusible con toma de corriente de la bateria.Se instalara en la cabina de conducci n en lugar visible y accesible.El micr fono estar ubicado en un lugar que permita ser utilizado por los tripulantes y permita leer telemetr a cardiaca. El equipo estar protegido contragolpes y rayos directos de sol y permitir conexi n selectiva al sistema de megafon a. La antena ser flexible y de longitud adecuada ajustada de manera que la relaci n de las ondas estacionarias (ROE.) sea menos de 1.5:1 se instalara antena vehicular de 5/8 de onda. Se instalara sobre el eje longitudinal del veh culo lo mas pr ximo al centro del veh culo. Ser montado sobre un plano de tierra artificial constituido por placa conductora de 0.1m x 0.1m El cableado ir por la parte interna del veh culo con lugar accesible en caso de reparaciones. El radiotel fono operara en dos metros de longitud de onda y apertura de frecuencia entre 135.000 y 160.000 con rango lateral de 12.5 Mhz,salida m nimo de 20w de potencia de transmision.Poseera m nimo dos canales y m ximo cuatro fijos y tarjeta de tonos. Se programara por medio de software. CARROCERIA: Estructura en l mina calibre "18" forrada en la parte exterior en l mina de aluminio de 2mm. Llevara parachoques delantero y trasero resistente a los golpes y sobrepasar en 50 Mm. los verticales de los extremos delanteros. W913FT-12-T-0111 Page 19 of 45 PUERTAS: La ambulancia tiene (4) accesos: Dos en la cabina de conducci n a cada lado del veh culo con bloqueo mediante llave y acceso por control interior.Apertura sobre giro vertical hacia adelante y ngulo de 75 grados.Presentaran altura m nima de 0.60 mts. El acceso principal se har por medio de puerta trasera en dos hojas verticales con chapa,manija,seguro de llave, control interior y vidrio fijo polarizado en la parte superior.Tendran una altura til de 1.10 m y de 1.20 m de ancho como m nimo. El cuarto acceso se ubicara en el costado derecho de la ambulancia de apertura til de 0.60 mts de ancho y 1,.10 mts de alto como m nimo girando sobre su eje vertical con pelda o antideslizante.Todos los pelda os ser n antideslizantes. Las puertas tienen dise o para evitar apertura accidental, mecanismos de apertura interiores y exteriores mediante llave.En el tablero del conductor se instalara piloto indicador de puertas abiertas con di metro de 10mm e iluminaci n intermitente con frecuencia entre 2hz Y 4hz.se designar mediante rotulo de PUERTAS ABIERTAS. Todas las puertas ser n herm ticas contra polvo,agua,aire en la parte interior de las mismas se instalara franjas de color reflectivo rojo para que la se alizaci n sea m xima cuando est n totalmente abiertas. VENTANAS: Todas las ventanas cumplen la ntc 1467.Las ventanas de las puertas de cabina se accionaran verticalmente.Todas las ventanas estar n en el tercio superior con vidrios de seguridad homologadas para uso automotriz en la zona del paciente,y estar n polarizadas con visibilidad de adentro hacia afuera.Las dimensiones ser n m nimo de 30cms de alto por 40cms de largo. Las ventanas de la puerta trasera ser n fijas con dispositivo de martillo para fracturarlas.No habr ventana al lado izquierdo y todas las ventanas ser n herm ticas. REVESTIMIENTO INTERIOR: Forrada en material de f cil lavado y esterilizaci n sin elementos filudos o cortantes,de color blanco en poli ster reforzado en fibra de vidrio clase 8,retardante al fuego y resistente a desinfectantes con espesor de 4.5mm. PISO: En l mina calibre "18" prensada con puentes en calibre "12",cubierta con una l mina de triplex de "10" Mm. forrada en material antideslizante.Sera sin escalones y cualquier cambio de nivel se har mediante rampa inferior al 6%. W913FT-12-T-0111 Page 20 of 45 El material del piso subir hasta 50mm con relaci n al piso COMPARTIMENTO DEL PACIENTE: Tendr un asiento a la cabecera del paciente GABINETES: Se suministrar un gabinete para medicamentos resistentes a impactos,lavables sin bordes filudos,con puertas de corredera en acr lico traslucido,sistema contra apertura accidental y entrepa os con altura graduable. Ser de tipo piso techo pared a pared. Se suministrara un compartimento aislado para los cilindros y ser de tipo centralizado fijo con man metros visibles y regulables desde el compartimiento del paciente. Todos los equipos m dicos ser n asegurados sin detrimento de su movilidad. La ambulancia llevara barra pasamanos en el centro a todo lo largo del compartimiento de pacientes para el sostenimiento del personal asistencial. SILLA ACOMPA ANTE: Asiento lateral construido sobre mueble para almacenamiento con colchoneta herm tica y lavable de color claro con cinturones de seguridad para dos personas con protecci n en el panel lateral para las cabezas de los ocupantes y ser el sitio para la camilla adicional con cinturones para su transporte cuando este en uso. SILLA TRIPULANTE: Asiento a la parte del compartimiento del paciente y destinado a la persona que atiende al enfermo, dotado de cintur n de seguridad, espaldar y apoyacabezas.Se ubicara mirando hacia la camilla en su cabecera. LONGITUDES: Longitud m nima de la ambulancia de bomper a bomper:4.30 mts Del rea del paciente:longitud m nima: 2.20 mts ancho m nimo: 1.60 mts altura m nima: 1.35 mts CONDICIONES AMBIENTALES: TEMPERATURA Los equipos en la ambulancia se almacenaran entre temperaturas de -5oc a 45oc.La ambulancia podr mantener temperaturas entre 5oc y 45oc por 6h y utilizar el equipo W913FT-12-T-0111 Page 21 of 45 una vez que la temperatura haya variado entre 0oc y 40oc. Se instalara un aire acondicionado con control en el compartimiento de paciente con capacidad de conseguir temperatura m xima seca de 24oc en 20 min. y cumplir con la NTC 3476. El refrigerante ser ecol gico y se tomara el aire del exterior al lado contrario del exhosto. La ambulancia tendr extractor de olores con corriente a 12v.Estos equipos funcionan sin detrimento de la ambulancia NIVEL DE RUIDOS: Se cumplir la normatividad al respecto por el ministerio de salud con la mejor insonorizaci n posible. IMPERMEABILIDAD: La ambulancia superara una prueba de proyecci n de agua pulverizada por chorro de 7mm durante 2 min. y a 4 metros de distancia con apertura de 30 grados.No se debe encontrar despu s de la prueba se ales de agua dentro del veh culo. EXHOSTO: La ambulancia expulsara los gases del motor por un costado de la ambulancia por un costado posterior a las puertas laterales y anterior a las llantas traseras.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/91c5edae08924ab0d16362a315590e1a)
- Place of Performance
- Address: Bogota Branch (PARC Americas 410th CSB) KO Directorate of Contracting, Unit 5136 US Embassy Colombia APO AA
- Zip Code: 34038-0008
- Zip Code: 34038-0008
- Record
- SN02800072-W 20120713/120712000119-91c5edae08924ab0d16362a315590e1a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |