N -- Video and Duress Alarm System Install SDVOSB set-aside - Attachment
- Notice Date
- 7/24/2012
- Notice Type
- Attachment
- NAICS
- 561621
— Security Systems Services (except Locksmiths)
- Contracting Office
- Department of Veterans Affairs;VA Maryland Health Care System;Carl.Henderson3@va.gov410-642-2411 X6403;P.O. Box 1000, Bldg. 101, Room 26;Perry Point MD 21902
- ZIP Code
- 21902
- Solicitation Number
- VA24512R0396
- Response Due
- 8/3/2012
- Archive Date
- 10/2/2012
- Point of Contact
- Carl.Henderson3@va.gov 410-642-2411 X6403
- E-Mail Address
-
Contract Specialist Intern
(Carl.Henderson3@va.gov)
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- SCOPE OF WORK FORT MEADE VA CBOC Provide all work for a complete security system installation per attached drawings E102 and E601. Work includes but not limited to the following: PHARMACY 1.Provide RADC with PIMS, BMS, duress switches, Local Controller with Maglock, keypad, REX Button, Emergency Exit Button. BUILDING PERIMETER 1.Provide RADC with remote keypads, RIOX cards, Provide PIMS, BMS, duress switches, local controllers, each controller will have a Maglock, keypad, REX Button, Emergency Exit Button. ADD Room 1.Provide RADC with PIMS,1 BMS, duress switch, 1 Local Controller with Maglock, keypad, REX Button, Emergency Exit Button. CAMERAS 1.Provide cameras as located on drawings for both interior and exterior of the building. 2.Provide component cabinet with DVR and UPS, fiber converter rack, and fiber converters, connect fibers, AC Power, and Ethernet to customer's LAN. Including all cable connections and tampers to the RADC 3.Assist customer's IT department with setting up to the DVR for Ethernet connectivity 4.Provide disc of software to the customer. This disc controls the software that allows the VA to view and control cameras. 5. Provide UPS next to the DVR cabinet, and wire to commercial power and into the DVR cabinet. Connect the alarms to the RADC in the same room as the UPS. 6.Provide Monitor and PTZ Controller in room 176 and connect to local power outlets 7.Complete access control system including card access and electric door strike. DATA BASE/GRAPHICS/TESTING 1.Reconfigure software, data base, and graphics to support new configuration. Provide as-built set to append to ICIDS III as-builts drawings. A functional test will be conducted by contractor's Technical Specialist and Systems Administrative Officer.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAMHCS512/VAMHCS512/VA24512R0396/listing.html)
- Document(s)
- Attachment
- File Name: VA245-12-R-0396 VA245-12-R-0396_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=411119&FileName=VA245-12-R-0396-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=411119&FileName=VA245-12-R-0396-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA245-12-R-0396 VA245-12-R-0396_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=411119&FileName=VA245-12-R-0396-000.docx)
- Record
- SN02813887-W 20120726/120725000531-57386039375604a76a08fa2787095fad (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |