SOLICITATION NOTICE
99 -- MARKET SURVEY: Repair of the chilled and condenser water system in the Administration Wing of the Oakland Air Route Traffic Control Center (ZOA) located in Fremont, CA.
- Notice Date
- 8/10/2012
- Notice Type
- Presolicitation
- Contracting Office
- FEDERAL AVIATION ADMINISTRATION, AAQ-530 AWP - Western Pacific
- ZIP Code
- 00000
- Solicitation Number
- 12163
- Response Due
- 8/17/2012
- Archive Date
- 9/1/2012
- Point of Contact
- Elsa Pineda-Gonzalez, 310-725-7499
- E-Mail Address
-
elsa.gonzalez@faa.gov
(elsa.gonzalez@faa.gov)
- Small Business Set-Aside
- N/A
- Description
- NOTE: If viewing this announcement from a source other than the FAA Contract Opportunities website, please visit http://faaco.faa.gov for the original announcement. Updates and or amendments will only be issued through the FAA Contracting Opportunities Website. Introduction/Description: The Federal Aviation Administration (FAA) Western Service Area has a requirement to repair the chilled and condenser water system located in the chiller room of the Administration Wing at the Oakland ARTCC. The period of performance for this requirement has been established as thirty (30) calendar days. Interested vendors are advised of the following: (a)This is not a Screening Information Request for Proposals of any kind; (b)The FAA is not seeking or accepting unsolicited proposals; (c)The FAA will not pay for any information received or costs incurred in preparing the response to the market survey; and (d)Any costs associated with this market survey submittal is solely at the interested vendor's expense Work includes but is not limited to the following: A. Replace condenser water supply drain lines including associated valves for all four chillers. B. Replace automatic air vents, taps, valves, and vent lines on chilled water supply and return piping for all four chillers. C. Replace two drain lines and valves for the cooling tower bypass. D. Replace 8 inch condenser water supply pipe from the flow control valve to the chiller connection on Chiller-300. Remove condenser supply temperature and pressure gauges. Replace nipples, fittings, and valves and reinstall temperature and pressure gauges. Salvage 8" elbow for facility spare use. E. For all four chillers, remove chilled water supply temperature and pressure gauges/indicators. Replace nipples, fittings, and valves and reinstall existing temperature and pressure gauges. F. Replace chilled water drain line and associated valves on Ch-400. The Government intends to award a firm-fixed price contract to the low priced technically acceptable offer. Anticipated Dollar Range: Under $100,000.00 The acquisition strategy for this procurement has not been determined at this time; however, either an unrestricted competition or set-aside will be chosen depending on the responses to this market survey. In order to make this determination and be considered responsive, interested offerors must submit the following to elsa.gonzalez@faa.gov by 2:30 PM PDT on Friday, August 17, 2012: a.Completed Business Declaration Form (attached) b.Copy of SBA 8(a) Certification Form or proof of documentation from Service-Disabled Veteran-Owned Small Business (if applicable). T3.6.1 - Small Business Development Program (Revision 21, October 2007) Small Business Development 5: DOT Lending Program This notice is for informational purposes for Minority, Women-Owned and Disadvantaged Business Enterprises: The Department of Transportation (DOT), Office of Small and Disadvantaged Business Utilization, has a program to assist small businesses, small businesses owned and controlled by a socially and economically disadvantaged individuals, and women-owned concerns to acquire short-term working capital assistance for transportation-related contracts. Loans are available under the DOT Short Term Lending Program (STLP) at prime interest rates to provide accounts receivable financing. The maximum line of credit is $750,000. For further information and applicable forms concerning the STLP, call the OSDBU at (800) 532-1169. NAICS Code: 238220 - Chilled water system installation Size standards in millions of dollars: $14.0
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOT/FAA/WPR/12163/listing.html)
- Record
- SN02834409-W 20120812/120810235424-abf1a77b3bed12685dcf93a27a4f6106 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |