99 -- MARKET SURVEY-Viking Fire Alarm Upgrade, Oakland ARTCC

Notice Date
8/10/2012
 
Notice Type
Presolicitation
 
Contracting Office
FEDERAL AVIATION ADMINISTRATION, AWP-52 AWP - Western Pacific
 
ZIP Code
00000
 
Solicitation Number
12157
 
Response Due
8/17/2012
 
Archive Date
9/1/2012
 
Point of Contact
Deana Galloway, 310-725-7548
 
E-Mail Address
deana.galloway@faa.gov
(deana.galloway@faa.gov)
 
Small Business Set-Aside
N/A
 
Description
The FAA has a requirement for Upgrading the Fire Suppression System in Oakland ARTCC. Work includes but is not limited to the following: Upgrade existing Firecycle II systems to Firecycle III systems. Rewire existing Firecycle III systems control panel pressure switch inputs in accordance with Viking Installation Instructions. Set all soak timers to 5 minutes on all Firecycle systems. Provide and install system isolation test valves and tamper switches as required on the drawings. Provide and install flow pressure switches as required on the drawings Modify existing sprinkler piping in the Control Room Basement to reposition sprinkler heads to within 6 inches of the ceiling. Provide additional thermal detectors as indicated in the drawings in the Automation Wing Basement. Repair leaks in the trim piping as indicated in the drawings. Perform acceptance test for all Firecycle systems (8 total) at the facility. Interface new flow pressure switch and tamper switch with the building's fire alarm system. Re-wire, re-terminate and reprogram building fire alarm system with Firecycle control panel per standard practices as indicated on the drawings Test and re-certify existing building fire alarm system upon completion of work. Fire Alarm Testing and Firecycle system testing shall be coordinated. New and existing penetration for conduit /cabling runs installed during this project shall be firestopped per project specifications. This procurement is anticipated to be a firm fixed price contract with a period of performance of sixty calendar days. At this time the nature of the final competition has not been determined. The FAA may decide to do a full and open competition or set aside the procurement for small business, service disabled veteran owned small business or eligible socially and economically disadvantaged businesses that are certified by the SBA for participation in the SBA's 8(a) program. The NAICS Code for this procurement is as follows: 238220 Fire sprinkler system installation This is not a Screening Information Request or Request for Proposals of any kind; The FAA is not seeking or accepting unsolicited proposals; The FAA will not pay for any information received or costs incurred in preparing the response to the market survey; and Any costs associated with the market survey submittal is solely at the interested vendor's expense In order to make this determination and to be considered responsive, the FAA requires the following information from interested vendors: Capability statement addressing the ability to meet all the requirements identified. Completed Business Declaration Form (attached) Copy of SBA 8(a) Certification from or proof of documentation from service-disabled veteran-owned small business (if applicable)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOT/FAA/WPR/12157/listing.html)
 
Record
SN02834786-W 20120812/120810235859-8f8f0e920ceef5d3c08c2ee9882664e9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.