DOCUMENT
66 -- Wizard 2480 Gamma Counter - Attachment
- Notice Date
- 8/17/2012
- Notice Type
- Attachment
- NAICS
- 334519
— Other Measuring and Controlling Device Manufacturing
- Contracting Office
- Department of Veterans Affairs;Orlando VA Medical Center;5201 Raymond Street;Orlando FL 32803
- ZIP Code
- 32803
- Solicitation Number
- VA24812I2561
- Response Due
- 8/22/2012
- Archive Date
- 9/21/2012
- Point of Contact
- Anita Leitch
- Small Business Set-Aside
- N/A
- Description
- This is a SOURCES SOUGHT notice. This is only a request for information. This is not a solicitation and no contract will be awarded from this announcement. Pursuant to FAR Part 10 (Market Research), the purpose of this notice is to determine if there are any Service Disabled Veteran Owned Small Businesses (SDVOSB), Veteran-Owned Small Businesses (VOSB), or any other small business socioeconomic category capable of providing the following medical equipment. Competition and set-aside decisions may be based on the results of this market research. All businesses able to provide this equipment are encouraged to submit information regardless of business size. This notice in no way obligates the Government to any further action. Vendors that can meet the requirements described below are to submit company information below as well as product information pertaining to the items being requested. Submit all information electronically to anita.leitch@va.gov. Phone inquires will not be accepted. All responses must be received no later than 12 NOON on August 22, 2012. Vendor Name Address Email and phone number DUNS Number Business Size GSA Contract (if applicable) Product information: All items are being procured on a brand name or equal basis. Please see salient characteristics. If equivalent items are proposed, please provide adequate descriptions: Manufacturer's name, Make/model name, number/product number. ITEM DESCRIPTION OF QTY UNIT NO. SUPPLIES/SVCS 1 Product Number: 2480 WIZARD21 EA WIZARD 2480 GAMMA COUNTER/TRICARB 3110 LIQUID SCINTILLATION COUNTER Manufacturer: PerkinElmer 2. Product Number: TRI-CARB 3110TR1 EA TRICARB 3110 LIQUID SCINTILLATION COUNTER 3 OPERATOR & MAINTENANCE/SERVICE MANUAL 2 EA 4 BIOMEDICAL TRAINING 1 EA 5 OPERATOR TRAINING 1 EA SALIENT CHARACTERISTICS: -Detector system consists of a thallium activated, sodium iodide crystal. The crystal height is 80 mm (3.15 in) and diameter 75 mm (2.95 in). The detector uses 4p counting geometry. -Radiation shielding is present for the detector assembly and the conveyor. The detector assembly is surrounded by a minimum of 50 mm (2.0 in) of lead shielding above and below. The shielding against the conveyor is 75 mm (2.95 in) of solid lead. -Sample changer has a storage capacity of 100 racks (1000 samples, 3 mL tubes) or 54 racks (270 sample, 20 mL tubes). -Linear multichannel analyzer with 2048 channels. Dead time is 2.5  µs. -Counting efficiency is not highly dependent on sample volume. In 20 mL LSC vial, < 1%/mL change in relative counting efficiency for any nuclide in the range 0à ‚¬"20 mL is achieved. -Multi-parameter linear MCA (Multichannel Analyzer) with an effective resolution of 1/10 keV. -133Ba low energy external standard source and tSIE (transformed Spectral Index of External standard) calculations eliminate the effects of vial glow, plastic wall and cocktail changes on the DPM results. -A cassette-loaded bi-directional sample conveyor mechanism is standard with a sample capacity of either 408 standard 20 mL vials, or 720 small 4 or 7 mL vials. -Sample changer enables intermixing and counting of both large and small sample vials without special adapters. Includes both large vial (12-position) and small vial (18-position) cassettes. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/OrVAMC/Or675VAMC/VA24812I2561/listing.html)
- Document(s)
- Attachment
- File Name: VA248-12-I-2561 VA248-12-I-2561_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=445393&FileName=VA248-12-I-2561-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=445393&FileName=VA248-12-I-2561-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA248-12-I-2561 VA248-12-I-2561_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=445393&FileName=VA248-12-I-2561-000.docx)
- Record
- SN02845295-W 20120819/120818000521-7f4d5c4cbdacb58df683543724948376 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |