MODIFICATION
Z -- REPLACE COOLING SYSTEM AND CIRCULATING PUMP
- Notice Date
- 9/5/2012
- Notice Type
- Modification/Amendment
- Contracting Office
- BIA - Western Regional Office Division of Acquistion - Western2600 N. Central Avenue, Suite 400 Phoenix AZ 85004
- ZIP Code
- 85004
- Solicitation Number
- A12PS02332
- Response Due
- 9/7/2012
- Archive Date
- 9/5/2013
- Point of Contact
- Darren Nutter Contract Specialist 6022414567 darren.nutter@bia.gov;
- E-Mail Address
-
Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
- Small Business Set-Aside
- Total Small Business
- Description
- The purpose of this amendment is to incorporate answers to questions received before the question submission deadline and to extend the quotation submission deadline. The quotation submission deadline is extended to Friday September 07, 2012 at 1800 EST. The questions and answers are as follows: Question: The SOW mentions replacing existing equipment and an air cooled chiller but there is no chiller at the facility. Is it a requirement that the equipment is replaced with a system utilizing an air cooled chiller? Answer: The SOW does not indicate that the equipment must be replaced with a system utilizing an air cooled chiller. Question: The SOW lists an exhibit A for a floor plan of the building. I cannot find where this is attached to the solicitation and Sam did not have one. Is there a drawing available? Answer: Exhibit A was omitted from the posting in error. It can be requested by emailing darren.nutter@bia.gov. Question: Is all ducting is to be removed and replaced? Answer: Yes Question: If ducting is to be replaced, are the existing grills and drop locations to be used on the new system? Answer: The same existing grill and drop locations can be used on the new system if the vendor determines that it would be practical to do so. Question: Is there a description of the equipment that will be replaced, size of the packaged air cooled chiller, quantity and size of fan coil units or air handlers? Answer: 2-swamp coolers: Minneapolis MN 55440, season master & season vent central station air conditioners. 3- air handlers; 1. Mcquay serial # 36G00497-06 16X20X2 filter, model # LHD103CH. 2. Mcquay serial # 3SG00498-06 20x20x2 filter, model # LHD104CH. 3. Mcquay serial# 3SG00499-06 25x25x2 filter, model # LHD106CH.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOI/BIA/RestonVA/A12PS02332/listing.html)
- Place of Performance
- Address: Owyhee, Nevada
- Zip Code: 89832
- Zip Code: 89832
- Record
- SN02867743-W 20120907/120906000326-075509bf7af3724099242a25ebc19898 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |