DOCUMENT
J -- Annual Maintenance on Steam Sterilizers and Washers - Attachment
- Notice Date
- 9/6/2012
- Notice Type
- Attachment
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 8 (248);Room 315, Bldg. 2;10,000 Bay Pines Blvd;Bay Pines FL 33744
- ZIP Code
- 33744
- Solicitation Number
- VA24812I2859
- Response Due
- 9/10/2012
- Archive Date
- 9/15/2012
- Point of Contact
- James L. Jones
- Small Business Set-Aside
- Total Small Business
- Description
- DESCRIPTION/SPECS/WORK STATEMENT I.Provide all repair parts and service for maintenance on the Steris equipment detailed in the solicitation to include: -Century V116 Steam Sterilizers SN# 011030425, EE# 37745, Location: 2D100-100-BP -Century V116 Steam Sterilizers SN# 010910403, EE# 37747, Location: 2D107-100-BP -Reliance Synergy Washer SN# 3611205003, EE# 41927, Location: 1C104-100-BP -Reliance Synergy Washer SN# 3611205004, EE# 41963, Location: 1C104-100-BP -Reliance 130L Cart Washer SN# 3630605001, EE# 45198, Location: 1C103-100-BP -SC1224C Ultrasonic Cleaner SN# 3615107002, EE# 52799, Location: 1C104-100-BP -Century V148H Steam Sterilizer SN# 032070701, EE# 53023, Location: 1C109-100-BP -Century V148H Steam Sterilizer SN# 033280703, EE# 54443, Location: 1C109-100-BP -Century V148H Steam Sterilizer SN# 031590801, EE# 59436, Location: 1C109-100-BP -Century V148H Steam Sterilizer SN# 0303560914, EE# 65876, Location: 1C109-100-BP -Reliance 333 Sanitizer Washer SN# 3603108011, EE# 56418, Location: 431-OPC-FM -Reliance Vision Washer Disinfector SN# 3611709004, EE# 66531, Location: 1C104-100-BP -Eagle Series 3017 100% ETO Gas Sterilizers SN# 030640841, EE# 58716, Location: 433-OPC-FM -Eagle Series 3017 100% ETO Gas Sterilizers SN# 030660807, EE# 58717, Location: 433-OPC-FM -Eagle Series 3017 100% ETO Gas Sterilizers SN# 012440503, EE# 42239, Location: 1C109-100-BP -Eagle Series 3017 100% ETO Gas Sterilizers SN# 012490509, EE# 42240, Location: 1C109-100-BP -Eagle Series 3017 100% ETO Gas Sterilizers SN# 030260909, EE# 64179, Location: 1C109-100-BP -Eagle Series 3017 100% ETO Gas Sterilizers SN# 030640841032780834, EE# 64177, Location: 1C109-100-BP -Caviwave Ultrasonic Cleaner SN# 0311C1184, EE# 77398, Location: 1C104-100-BP II.Hours of coverage will be from 8:00 am through 5:00 pm Monday through Friday, excluding Federal Holidays (New Years Day, Martin Luther King Day, President's Day, Memorial Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day). All work done outside the normal coverage time should be first approved through the Biomedical Engineering Section, Ft. Myers. Preventive maintenance should be negotiated, during normal hours, at least two weeks in advance with the Biomedical Engineering Section, Bay Pines FL. Preventive maintenance will be done at the manufacturer's recommended frequency, replacing all parts recommended by the manufacturer, with oversight and confirmation of workmanship by personnel from Biomedical Engineering. Biological testing done after repairs or preventive maintenance, resulting in failed tests, will result in the contractor returning to correct any problems resulting in these failed tests. Testing will be performed by VA personnel. III.Hardware and software upgrades will be included, scheduled and performed during normal working hours, at no additional charge to the VA. These upgrades are those required for the correct function of the system; not those purchased to enhance function. IV.The contractor will provide all hardware and software necessary for unscheduled repairs. The contractor's field service engineer will respond by phone within 2 hours and respond on site within 48 hours to correct the problem. Uptime requirements, excluding scheduled preventive maintenance, will be 97% of the normal working hours and working days during the term of the contract. All broken parts used to repair the system will become the property of the contractor. V.The contractor must have trained personnel within a 300 mile radius of Bay Pines and Ft. Myers, Florida, with an adequate spare parts inventory in some area office and proof of manufacturer's or equivalent maintenance training of field service personnel. VI.Each scheduled and unscheduled visit will result in the production of a written report, by the contractor's representative, in a format negotiated between the VA and the contractor. The contractor will always contact the Biomedical Engineering Section, before and after arrival at the site. Contact Phone # is (727) 398-9401.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BPVAMC/VAMCCO80220/VA24812I2859/listing.html)
- Document(s)
- Attachment
- File Name: VA248-12-I-2859 VA248-12-I-2859_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=468350&FileName=VA248-12-I-2859-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=468350&FileName=VA248-12-I-2859-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA248-12-I-2859 VA248-12-I-2859_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=468350&FileName=VA248-12-I-2859-000.docx)
- Record
- SN02871382-W 20120908/120907001306-2682ea4c5bdf6aba987c393cf6855308 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |