MODIFICATION
95 -- HELIUM JACKETED DEUTERIUM STORAGE TANK AND VALVE MANIFOLD
- Notice Date
- 11/15/2012
- Notice Type
- Modification/Amendment
- NAICS
- 332420
— Metal Tank (Heavy Gauge) Manufacturing
- Contracting Office
- Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B129, Mail Stop 1640, Gaithersburg, Maryland, 20899-1640, United States
- ZIP Code
- 20899-1640
- Solicitation Number
- AMD-13-SS06
- Archive Date
- 12/15/2012
- Point of Contact
- Paula Wilkison, Phone: 301-975-8448, Todd D Hill, Phone: 301-975-8802
- E-Mail Address
-
paula.wilkison@nist.gov, todd.hill@nist.gov
(paula.wilkison@nist.gov, todd.hill@nist.gov)
- Small Business Set-Aside
- N/A
- Description
- Additional information for vendors interested in the helium jacketed deuterium storage tank and valve manifold requirement: Leak tests for both the inner deuterium storage vessel with the valve manifold connected and the outer helium vessel and connected valve box shall each be performed with a helium mass spectrometer. The test shall be performed after all welding has been finished and the pneumatic pressure test has been successfully completed. The leak rate shall not exceed 1x10-9 std. cc/sec for either test.