Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 21, 2012 FBO #4045
DOCUMENT

C -- REPLACE UNDERGROUND STEAM MAINS | 575 GRAND JUNCTION - Attachment

Notice Date
12/19/2012
 
Notice Type
Attachment
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office;NCO 19;4100 E. Mississippi Avenue, Suite 900;Glendale CO 80246
 
ZIP Code
80246
 
Solicitation Number
VA25913R0212
 
Archive Date
3/19/2013
 
Point of Contact
Tracy Lynn Jackson
 
E-Mail Address
3.3272<br
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
THIS IS A PRE-SOLICITATION NOTICE ONLY. THE GOVERNMENT RESERVES THE RIGHT NOT TO SOLICIT OR AWARD THIS REQUIREMENT. DESCRIPTION: This contract will provide for engineering, design and contract solicitation documents as required for the construction of the project through public solicitation. The project Replace Underground Steam Mains is located on the grounds of the VA Medical Center, Grand Junction, Colorado. The Engineering Firm shall utilize skills and knowledge to design and develop contract drawings, specifications and procedures necessary to meet the mission needs of the Medical Center. 1.Determine and develop means of maintaining steam utility service during periods of pipe line construction. 2.Provide all labor, materials and equipment as required to determine soil conditions of the steam mains replacement. 3.Determine and develop excavation procedures to remove existing subsurface steel steam distribution piping. Excavation shall also include existing cathodic protection array. 4.Determine and develop the design for steam control cubicles 5.Determine and develop the design required to install a new steam supply and steam condensate piping system. 6.Develop, edit and coordinate specifications for construction work and products. 7.Develop construction drawings for solicitation. 8.Provide construction period services of review and inspection during construction contract award. 9.Provide Drawings of Record upon completion of construction contract. NARRATIVE: The existing steam distribution piping consists of fiberglass covered ductile iron piping with individual cal-sil covered steam piping contained in the interior. The original piping (1982) was installed with a sacrificial anode cathodic protection array. With a historically high water table, the cathodic protection array has failed, resulting in deterioration to the exterior primary pipe. The cal-sil pipe insulation of the interior distribution piping is expected to be deteriorated as the ground surface during the winter months remains clear of snow. The piping in the manholes has deteriorated to a point of being unserviceable. The size of the manholes and the subsurface location prevents economical and safe preventive maintenance and repair within the space. INTENT: This scope expects the Engineering Firm to design a new exterior steam piping system in accordance with industry standards, the VA Master Specifications and VA Design Guidelines. The design shall include connections to all campus buildings utilizing steam. New piping shall be sized to meet future steam loads. GENERAL: All design and work will conform to the current edition of the VA Master Specifications and VA Design Standards as published at the following site: www.cfm.va.gov, code of Colorado Regulations, EPA, ASHRAE, IBC 2003, NFPA and NEC building code and standards. Solicitation will be issued in the month of January 2013, on fbo.gov. SET-ASIDE: At this time, this will be a Service Disabled Veteran Owned Business, utilizing NAICS 541330 for Professional Engineering. CONTRACTING OFFICE ADDRESS: Department of Veterans Affairs ; Network Contracting Office, 19; 4100 East Mississippi Avenue #900; Glendale, CO 80246 PLACE OF PERFORMANCE: Grand Junction, CO VAMC at 2121 North Avenue, Grand Junction, CO 81501 POINT OF CONTACT: Tracy Lynn Jackson Contract Specialist Tracy.jackson2@va.gov 303.603.3272
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/VA25913R0212/listing.html)
 
Document(s)
Attachment
 
File Name: VA259-13-R-0212 VA259-13-R-0212.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=561331&FileName=VA259-13-R-0212-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=561331&FileName=VA259-13-R-0212-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Grand Junction, CO VAMC at 2121 North Avenue;Grand Junction, CO
Zip Code: 81501
 
Record
SN02951727-W 20121221/121219234242-14e89a10334aaf7c5a5a3a278cdee071 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.