Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 21, 2012 FBO #4045
SOURCES SOUGHT

58 -- FMS Case MD-B-UBG A4

Notice Date
12/19/2012
 
Notice Type
Sources Sought
 
Contracting Office
ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
 
ZIP Code
21005-1846
 
Solicitation Number
MARKET-SURVEY-5372-1
 
Response Due
1/4/2013
 
Archive Date
2/17/2013
 
Point of Contact
Tineka C. Davis, 443-861-5437
 
E-Mail Address
ACC-APG - Aberdeen Division B
(tineka.c.davis.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
FOR MORE INFORMATION PLEASE CONTACT: Mitch Jacquay 443-861-4396 mitchell.a.jacquay.civ@mail.mil, Franklin Lee 443-861-4395 franklin.f.lee.ctr@mail.mil, Tony Blais 443-861-4399 anthony.w.blais.civ@mail.mil You must respond NO LATER than the Respond Date and Time The ACC-APG -C4ISR intends to acquire: I.Qty. (1) Utility/Auxiliary Power System including the following items: a.Qty. (2) each Gillette GPNDL-60E Portable Diesel Power Generator Type(or similar) with wheel kit i.Salient Characteristics: 1.Voltage:120/240(v) 2.Power Output:5 kW (6 kW Max) 3.Amperage (A) :42/21(A) 4.Engine Type: a.Diesel b.9 Horsepower (HP) 5.Fuel Tank: 4 Gallon 6.Weight: 191lbs. (not to exceed) 7.Connector Qty. and Types: a.4 - 120V (NEMA 5-15R) b.1 - 120V (NEMA L5-30R) c.1 - 240V (NEMA L14-20R) 8.Special Features: a.Clean Power ( less than 7% Harmonic Distortion) b.Automatic Load Balance c.Insulation Design (Heat Reduction for increased Winding Life) d.2-Element Heavy - Duty Air Cleaner e.Heavy - Duty Diodes f.Heavy - Duty Diodes g.Wheel Kit for increase user mobility b.Qty. (1) each Distribution Panel with Transfer Switch i.Salient Characteristics 1.Panel Type:Similar to TCA0603DR 2.Max Generator Running Power:7.5 kW 3.Phase:Single 4.Shipping Weight: 12 lbs. 5.Dimensions (H x W x D):13x11.125x3.5 (inches) 6.Cabinet Type, NEMA:Outdoor, NEMA 3R 7.Special Features: a.Circuit Breaker Combinations: i.Utility60 - 125 A ii.Generator30 - 125 A iii.Interlinked circuit breakers to keep generator power isolated from utility power at all times. iv.Heavy - Duty Copper Bus c.Qty. (4) 20 meter (approx 60ft.) Commercial Power cable (pigtail) with NEMA appropriate connector. Cables should connect the Generators to the Distribution Panel. i. Salient Characteristics 1.Connector type on one end of the cable:NEMA (L14-20R) 2.Max Current Load:20A (max) II.Spare Generators for the Utility/Auxiliary Power System a.Qty. (4) each Gillette GPNDL-60E Portable Diesel Power Generator Type(or similar) with wheel kit i.Salient Characteristics: 1.Voltage:120/240(v) 2.Power Output:5 kW (6 kW Max) 3.Amperage (A) :42/21(A) 4.Engine Type: a.Diesel b.9 Horsepower (HP) 5.Fuel Tank: 4 Gallon 6.Weight: 191lbs. (not to exceed) 7.Connector Qty. and Types: a.4 - 120V (NEMA 5-15R) b.1 - 120V (NEMA L5-30R) c.1 - 240V (NEMA L14-20R) 8.Special Features: a.Clean Power ( less than 7% Harmonic Distortion) b.Automatic Load Balance c.Insulation Design (Heat Reduction for increased Winding Life) d.2-Element Heavy - Duty Air Cleaner e.Heavy - Duty Diodes f.Heavy - Duty Diodes g.Wheel Kit for increased user mobility REQUIRED INFORMATION: 1.If you are a reseller/distributor you MUST disclose the manufacturer of ALL ITEMS listed. 2.Please furnish price quotes for lot sizes of 1-9, 10-24 and 25-49 for each of the two configurations. 3.You MUST reference the FMS case designator on your formal solicitations. 4.A quality system to monitor a phases of manufacturing will be requested after contract award. 5.Identify whether you are a small or large business 6.If you are a small business then identify your subcategory, i.e. 8A, SDB, SDVOB, etc. Respond to My Attention by COB Eastern on 4 January 2013 Mitchell Jacquay, Email mitchell.a.jacquay.civ@mail.mil, Franklin Lee, Email franklin.f.lee.ctr@mail.mil, Tony Blais, Email anthony.w.blais.civ@mail.mil
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/95d9b1549db37fe62ac8a3d4207e5372)
 
Place of Performance
Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
Zip Code: 21005-1846
 
Record
SN02952708-W 20121221/121219235320-95d9b1549db37fe62ac8a3d4207e5372 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.