Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 27, 2013 FBO #4113
SOURCES SOUGHT

Z -- Licensed Electrical Contractor

Notice Date
2/25/2013
 
Notice Type
Sources Sought
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Labor, Employment Training Administration, Westover Job Corps Center, 103 Johnson Drive, Chicopee, Massachusetts, 01022
 
ZIP Code
01022
 
Solicitation Number
02252013
 
Point of Contact
Cheryl Shaughnessy, Phone: 4135934015
 
E-Mail Address
shaughnessy.Cheryl@jobcorps.org
(shaughnessy.Cheryl@jobcorps.org)
 
Small Business Set-Aside
N/A
 
Description
The Westover Job Corps Center in Chicopee Mass is accepting Bids for a Electrical Sub-Contractor for work to be performed on site at: Westover Job Corps Center 103 Johnson Road, Chicopee, MA 01022. Bids are to be submitted no later then March 15th, 2013 at close of business. Bids should be submitted in a sealed envelope and address to Purchasing, Attn: Cheryl Shaughnessy. Walk through for Interested Contractors is being held on March 4th, 2013 by appointment. Please call Cheryl Shaughnessy at 413-593-4015 to schedule. See Detailed Scopes of Work Below. Project 85761(Building 5650 – Center Maintenance) Scope of Work: In the maintenance shop re-lamp the existing industrial type light fixtures replacing 4 lamps with 3 lamps. Replace two ballasts with one ballast suitable for three-lamp application. In the storage areas reduce amount of fixtures, utilizing about 12 strip type light fixtures in the large storage area and 2 strip type light fixtures in the small storage room; fixtures to have 2 T8 lamps and wire guard. In the offices replace the existing light fixtures with total of three 2’x4’ wrap-around light fixtures, each with two T8 lamps (two fixtures in the large office and one in the small office). For the entrance area retrofit two existing 2’x4’ light fixtures. Clean the lenses for all retrofitted light fixtures prior to re-installation. For cost estimating, assume retrofit of (22) light fixtures and replacement of (3) 2’x4’ wrap-around light fixtures, each with two T8 lamps. Project 85769(Building – Carpentry Shop) Scope of Work: In the classroom, instructor’s office, mechanical room and toilet rooms retrofit the existing fixtures with T 12-fluorescent lamps and matching electronic ballast. Provide lighting levels according to the space utilization: 35 foot-candles (fc) for the classroom and instructor’s office, 20 fc for toilet rooms and mechanical rooms. Reduce amount of lamps and ballasts as necessary to achieve required lighting levels. In classroom retrofit 6 fixtures, (2 T8-lamps), in the office retrofit 2 fixtures (3-T8-Lamps), in two toilet rooms retrofit 4 fixtures, (1 T8-lamp), and in the mechanical room retrofit 2 fixtures, (2 T8-lamps). Provide wall-mounted occupancy sensors in the above mentioned rooms with exception of the mechanical room (utilize the existing on/off switch). In the carpentry shop replace the existing T 12 light fixtures with approximately 12 high bay industrial type, 4-lamp, 4’ T5HO 54W-fluorescent fixtures (for the shop area), and 7 low bay industrial type 2 lamp T8 light fixtures (for the mezzanine area). For cost estimating, assume retrofit of (14) fluorescent fixtures and the installation of 12 new high bay industrial type 4-lamp, 4’ T5HO-fluorescent fixtures (54W per lamp), each with matching electronic ballast and wire guard, 7 low bay industrial type, 2-lamp T8 light fixtures (for mezzanine area) and 4 wall-mounted occupancy sensors. Project 85787(Building 5690 – Equipment Storage) Scope of Work: Replace four existing HD light fixtures in the storage area with energy-efficient high bay T8 fluorescent fixtures. For estimating, assume the installation of (4) 4’ chain-mounted (chain length 3”) high bay industrial type fixtures, each with three T8 fluorescent lamps and electronic ballast. Fixtures shall additionally have wire guards. Connect the new fixtures to the existing branch circuit wiring as allowable by NEC. Re-wire light fixtures to provide dual switching in the main storage area and provide wall mounted occupancy sensor to turn all lights off. For cost estimating, include the installation of 4 new, chain-mounted industrial type high bay energy efficient fluorescent light fixtures, each with 3 T8 fluorescent lamps, electronic ballasts (ULTRAMAX or equal) and wire guard, 50’ of 3 #12 wire in ˝” EMT, and small scissor lift for a ˝ day. Project 85790(Building 5693 – Construction Voc.) Scope of Work: Retrofit the existing T12 fluorescent fixtures with T8 lamps, matching electronic ballasts and high-efficiency reflectors. For fixture with four T12 fluorescent lamps, retrofit using three T8 fluorescent lamps and one matching electronic ballast. For fixture with three T12 fluorescent lamps, retrofit using two T8 fluorescent lamps and one matching electronic ballast. For fixture with two T12 fluorescent lamps, retrofit using two T8 fluorescent lamps and one matching electronic ballast. Reduce amount of light fixtures, if necessary, providing DOL required lighting levels of 50 FC for the shop area and 20 fc for the storage rooms and toilet rooms. Provide listed high intensity reflectors inside the fixtures. Replace all broken lenses and sockets. Clean the remaining lenses. For cost estimating assume retrofit of (30) light fixtures. Project 85803(Building 5902 – Men’s Dorm) Scope of Work: Rewire existing corridor lighting such that corridor lighting will have double switching. Every third light fixture should be switched separately from the rest of the fixtures and designated as night lighting. Night light fixtures will stay on longer hours than the rest of the fixtures, which can be switched off after hours. Project 85804(Building 5903 – Women’s Dorm) Scope of Work: Rewire existing corridor lighting such that corridor lighting will have double switching. Every third light fixture should be switched separately from the rest of the fixtures and designated as night lighting. Night light fixtures will stay “on” longer hours than the rest of the fixtures, which can be switched “off” after hours. Project 85836(Building 5908 – Men’s Dorm) Scope of Work: Replace the existing fixtures with energy efficient fluorescent fixtures providing two 4’ all purpose wall brackets, each with one T8 lamp located above the mirrors in each of six bathrooms. Fixtures should be suitable for damp location. Connect fixtures to the existing wiring. For estimating, assume the installation of (12) 4’ all purpose wall brackets, suitable for damp locations, each with one T8 lamp.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOL/ETA/WestoverJCC/02252013/listing.html)
 
Place of Performance
Address: Westover Job Corps, 103 Johnson Road, Chicopee, Massachusetts, 01022, United States
Zip Code: 01022
 
Record
SN02994900-W 20130227/130225234112-b80fa6fd120b34fee4cb2f7e037c6f82 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.