Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 10, 2013 FBO #4155
MODIFICATION

66 -- Photoacoustic Detector Modules.

Notice Date
4/8/2013
 
Notice Type
Modification/Amendment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Health and Human Services, Food and Drug Administration, Office of Acquisitions and Grants Services, 5630 Fishers Lane, Room 2129, Rockville, Maryland, 20857-0001
 
ZIP Code
20857-0001
 
Solicitation Number
FDA-SOL-1116379
 
Archive Date
4/26/2013
 
Point of Contact
Emmanuel T. Mbah, Phone: 301 827 7156
 
E-Mail Address
Emmanuel.mbah@fda.hhs.gov
(Emmanuel.mbah@fda.hhs.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
AS A RESULT OF THE QUESTIONS BELLOW FROM VENDORS, THE MINIMUM SPECIFICATIONS FOR THIS REQUIREMENT HAVE BEEN REVISED. IF A VENDOR HAS ALREADY SUBMITTED A QUOTE AND THE SLIGHTLY REVISED SPECIFICATIONS DO NOT EFFECT YOUR PROPOSAL, YOU CAN IGNORE THIS AMENDMENT, OTHERWISE, YOU ARE FREE TO REVISE YOUR QUOTE. THE RESPONSE DUE DATE HAS ALSO BEEN REVISED TO 04/11/13 TO PROVIDE THE INTERESTED VENDORS AN OPPORTUNITY TO PARTICIPATE IN THIS REQUIREMENT. THE REVISED SEPCS ARE AS FOLLOWS: Minimum Specifications: 1. Compatibility with Shimadzu IRAFFINITY-1 FTIR spectrometer 2. Spectrum range: at least, 7,000 - 400 cm-1 with KBr window 3. Maximum microphone sensitivity: > 1 V/Pa at a scan speed within 5 Hz - 30 kHz 4. Capability of measuring solid, liquid, and gaseous samples using one or more interchangeable detector modules. 5. Variable gain control: > 10 steps QUESTIONS The microphone sensitivity specification does not state the frequency range. A 5 Hz to 20 kHz frequency range is required to accommodate the full range of FTIR operating parameters. A resonance-free, constant 10 V/Pa sensitivity from 5 Hz to 20 kHz, which is the frequency range of the..... microphone, has never been demonstrated by any photoacoustic detector manufacturer. A 10 V/Pa resonance-free sensitivity has only been demonstrated below approximately 1 kHz which is a serious limitation for a photoacoustic detector......... provides specific sampling heads for gas samples and for solid, semisolid, and liquid samples that all operate interchangeably with the...... PAC300 photoacoustic detector. Multiple photoacoustic detectors are not necessary with......'s technology to access these different types of samples. The signal inputs on FTIR spectrometers require an analog signal so digitizing the signal is not desirable prior to the FTIR input. The..... PAC300 detector has variable gains in 12 steps covering a gain range of 5000. This gain range has been proven to be fully adequate for all commercial FTIRs and all types of photoacoustic measurements.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/FDA/DCASC/FDA-SOL-1116379 /listing.html)
 
Place of Performance
Address: U.S. Food and Drug Administration (FDA), FDA/CDRH/OSEL, 10903 New Hampshire Avenue, Building 62, Room 1133, Silver Spring, MD 20993, Silver Spring, Maryland, 20993, United States
Zip Code: 20993
 
Record
SN03031039-W 20130410/130408234227-b51ad00e1440e16c384c57c75c459070 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.