SOLICITATION NOTICE
66 -- Fixtures for the calibration of laboratory grade single and multi-axis load cells
- Notice Date
- 9/18/2013
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 339999
— All Other Miscellaneous Manufacturing
- Contracting Office
- US Army Medical Research Acquisition Activity, ATTN: MCMR-AAA, 820 Chandler Street, Frederick, MD 21702-5014
- ZIP Code
- 21702-5014
- Solicitation Number
- W81XWH-13-T-0406
- Response Due
- 10/2/2013
- Archive Date
- 11/17/2013
- Point of Contact
- Abraham Pottenger, 301-619-2294
- E-Mail Address
-
US Army Medical Research Acquisition Activity
(abraham.pottenger.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Minimum Essential Characteristics Fixtures for the calibration of laboratory grade single and multi-axis load cells Description of Technology: The required supply is a set of calibration fixtures for mounting laboratory grade single and multi-channel load cells in a uni-axial universal test system for the purposes of calibrating the laboratory grade sensors. The required set of fixtures will be used to calibrate an existing stock of laboratory grade load cells manufactured by Robert A Denton, Inc. and Humanetic ATD, Inc. These calibration fixtures are being procured to support in-house calibration of laboratory grade load cells on an as-needed basis. Laboratory grade load cells are used to support USAARL's ongoing injury biomechanics research mission. To meet the needs of this research program, the required supply must meet the following minimum specifications. I.The required supplies must include at a minimum: a.At least one (1) calibration fixture compatible with both Robert A. Denton, Inc. Model 1716, 6-channel Upper Neck Load Cells and Robert A. Denton, Inc. Model 8070J, 6-channel FOCUS-specific Upper Neck Load Cells. b.At least one (1) calibration fixture compatible with Robert A. Denton, Inc. Model 7502J, 6-channel Lumbar Load Cells. c.At least one (1) calibration fixture compatible with Robert A. Denton, Inc. Model 1914, 6-channel Femur Load Cells. d.At least one (1) calibration fixture compatible with both Robert A. Denton, Inc. Model 1583 6-channel Upper Tibia Load Cells and Robert A. Denton, Inc. Model 4509, 5-channel Upper Tibia Load Cells. e.At least one (1) calibration fixture compatible with Robert A. Denton, Inc. Model 1584, 3-channel Lower Tibia Load Cells. f.At least one (1) calibration fixture compatible with Robert A. Denton, Inc. Model 4929, 5-channel Lower Tibia Load Cells. g.At least one (1) calibration fixture compatible with both Robert A. Denton, Inc. Model 8040J 3-channel Right Zygoma Load Cells and Robert A. Denton, Inc. Model 8045J, 3-channel Left Zygoma Load Cells. h.At least one (1) calibration fixture compatible with Robert A. Denton, Inc. Model 8055J 3-channel Mandible Load Cells. i.At least one (1) calibration fixture compatible with both Robert A. Denton, Inc. Model 8030J 3-channel Nasal Load Cells and Robert A. Denton, Inc. Model 8035J, 3-channel Frontal Bone Load Cells. j.At least one (1) calibration fixture compatible with Robert A. Denton, Inc. Model 8050J 3-channel Maxilla Load Cells. k.At least one (1) calibration fixture compatible with both Robert A. Denton, Inc. Model 8060J 3-channel Right Eye Load Cells and Robert A. Denton, Inc. Model 8065J, 3-channel Left Eye Load Cells. l.At least one (1) calibration fixture compatible with both Robert A. Denton, Inc. Model 4773 3-channel Barrier Load Cells and Humanetics ATD, Inc. Model 10490FL 3-channel Barrier Load Cells. II.Quotations for required supplies should include freight for shipping calibration fixtures to requesting agency's location on Fort Rucker, AL. Note via 52.212-2: An offeror is expected to submit sufficient information in response to the RFQ to allow for the evaluation of his/her quotation.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/USAMRAA/DAMD17/W81XWH-13-T-0406/listing.html)
- Place of Performance
- Address: US Army Medical Research Acquisition Activity ATTN: MCMR-AAA, 820 Chandler Street Frederick MD
- Zip Code: 21702-5014
- Record
- SN03193515-W 20130920/130918235647-1a04c1a95a0fc97ce0f810edb9225869 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)