DOCUMENT
66 -- Laboratory Centrifuges - Attachment
- Notice Date
- 1/27/2015
- Notice Type
- Attachment
- NAICS
- 333999
— All Other Miscellaneous General Purpose Machinery Manufacturing
- Contracting Office
- U.S. Department of Veterans Affairs;Strategic Acquisition Center;10300 Spotsylvania Ave;Fredericksburg VA 22408
- ZIP Code
- 22408
- Solicitation Number
- VA11915N0099
- Response Due
- 1/30/2015
- Archive Date
- 3/31/2015
- Point of Contact
- Debbie Frankovich
- Small Business Set-Aside
- N/A
- Description
- TABLE 1: All Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR1Timer range: 1 second-99 minutes Literature review MTR2Accommodate tubes of 0.1 to 10 mLLiterature review MTR3Minimum RPM speed of 3000 Relative Centrifugal Force (RCF) x gLiterature review MTR4Maximum allowed noise level, 60 dB(A)Literature review MTR5Safety lock (remains engaged until rotor stops)Literature review MTR6Automatic off-balance rotor detector shut offLiterature review MTR7Power requirement of 60HzLiterature review TABLE 2: Superspeed Refrigerated Floor Model Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8Maximum of 40 tube positions per rotor Literature review MTR9Minimum RCF of 70,450 x gLiterature review MTR10Accommodate sample volume ranges from 1.5-1,000 mLLiterature review MTR11Designated rotors (fixed angles, swinging buckets, continuous flow or zonal)Literature review MTR12Refrigerated with digital display of internal temperatureLiterature review TABLE 3: Superspeed Unrefrigerated Floor Model Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8Maximum of 40 tube positions per rotor Literature review MTR9Minimum RCF of 70,450 x gLiterature review MTR10Accommodate sample volume ranges from 1.5-1,000 mLLiterature review MTR11Designated rotors (fixed angles, swinging buckets, continuous flow or zonal)Literature review MTR12UnrefrigeratedLiterature review TABLE 4: Ultracentrifuge Floor Models MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8RCF up to 802,000 x g Literature review MTR9Accommodate sample volumes up to 250 mLLiterature review TABLE 5: Bench-top General Purpose Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8RCF up to 24,000 x gLiterature review MTR9Accommodate tubes of 0.2 through 750 mLLiterature review MTR10Designated rotors (fixed angles, swinging buckets, continuous flow or zonal)Literature review MTR11Audible and/or visual end-of-run alarmLiterature review TABLE 6: Bench-top Microcentrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8RCF up to 21,000 x gLiterature review MTR9Spin up through 2 mL volumesLiterature review MTR10Rotors that accept 0.2 mL PCR tubes and 1.5 mL/2.0mL tubes and filtersLiterature review TABLE 7: Bench-top Clinical Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8RCF up to 3,000 x gLiterature review MTR9Accommodate tubes of 3 through 15 mLLiterature review MTR10Accommodate from 4 through 28 tubes per run, dependent on tube size and unitLiterature review MTR11Designated rotors (fixed angles, swinging buckets, continuous flow or zonal)Literature review MTR12Audible and/or visual end-of-run alarmLiterature review TABLE 8: Bench-top Cell Washer Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8RCF up to 1,500 x gLiterature review MTR9Supports 3 and 5 mL culture tubesLiterature review MTR10Accommodate 12x75 mm tubesLiterature review MTR11Accommodate minimum of 12 tubes per runLiterature review MTR12Ability to adjust number of wash cycles, volume of saline dispensed, number or time of agitation, and the decant speedLiterature review MTR13Automatic shake step prior to each wash cycleLiterature review MTR14Audible and visual end-of-run alarmLiterature review TABLE 9: Bench-top Refrigerated High Speed Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8RCF up to 50,000 x gLiterature review MTR9Low-speed, high-volume swing-out rotorLiterature review MTR10High-speed, mid-volume (i.e. 15-50 mL) fixed angle rotorLiterature review MTR11High-speed, low-volume (i.e. 1.5 mL/2.0 mL) fixed angle rotorLiterature review TABLE 9: Bench-top Refrigerated High Speed Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR12Accommodate volume range of 1.5-200 mL, dependent on type of rotorsLiterature review MTR13Designated rotors (fixed angles, swinging buckets, continuous flow or zonal)Literature review MTR14Refrigerated with digital display of internal temperatureLiterature review TABLE 10: Bench-top Unrefrigerated High Speed Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8RCF up to 50,000 x gLiterature review MTR9Low-speed, high-volume swing-out rotorLiterature review MTR10High-speed, mid-volume (i.e. 15-50 mL) fixed angle rotorLiterature review MTR11High-speed, low-volume (i.e. 1.5 mL/2.0 mL) fixed angle rotorLiterature review MTR12Accommodate volume range of 1.5-200 mL, dependent on type of rotorsLiterature review MTR13Designated rotors (fixed angles, swinging buckets, continuous flow or zonal)Literature review MTR14UnrefrigeratedLiterature review TABLE 11: Bench-top Micro-ultra Centrifuges MTR NumberMinimum Technical Requirement (MTR)Method of Evaluation MTR8RCF g forces > than 1,000,000Literature review MTR9Accommodate micro-volume samples ? 13.5 mLLiterature review MTR10Designated rotors (fixed angles, swinging buckets, continuous flow or zonal)Literature review
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/4ea1f8ed84c56d9ba00162264018c894)
- Document(s)
- Attachment
- File Name: VA119-15-N-0099 VA119-15-N-0099_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1832475&FileName=VA119-15-N-0099-001.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1832475&FileName=VA119-15-N-0099-001.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA119-15-N-0099 VA119-15-N-0099_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1832475&FileName=VA119-15-N-0099-001.docx)
- Record
- SN03625851-W 20150129/150127234543-4ea1f8ed84c56d9ba00162264018c894 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |