Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 31, 2015 FBO #4816
SPECIAL NOTICE

J -- WPC Uninterrupted Power Supply (UPS) Repair

Notice Date
1/29/2015
 
Notice Type
Special Notice
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
US Air Force Europe - 700 CONS
 
ZIP Code
00000
 
Solicitation Number
F3NF114311A001
 
Archive Date
2/28/2015
 
Point of Contact
Susanne Schorr, Phone: 496315366611, Andrew Feutz, Phone: 011496315367999
 
E-Mail Address
susanne.schorr.de@us.af.mil, andrew.feutz@us.af.mil
(susanne.schorr.de@us.af.mil, andrew.feutz@us.af.mil)
 
Small Business Set-Aside
N/A
 
Description
NOTICE OF INTENT TO AWARD SOLE SOURCE 29 January 2015 The USAFE Warrior Preparation Center (WPC) hereby formally announces the intent to award a firm-fixed price purchase order on a sole source basis to Eaton Corporation. This is a one-time repair purchase. The repair requires: Qty Part/Name/Part Number 3 TA1200NB1 Terminal Lugs (4) 4/0-500MCM CU/AL for Maintenance Bypass Output Bus. Part# 101073073-001 1 Eaton Panelboard 23Circuits, 400A, Fully Rated, 415/240V 3Ph 4W, Copper Bus, 50k AIC, 400A, HKD 3P Main Breaker[Top Fed], Surface Mounted Qty List of Materials 1 400A, HKD 3P Main Breaker 1 20A, 1P HFD Branch Breaker 5 100A, 3P HFD Branch Breaker 4 15A, 1P HFD Branch Breaker 1 30A, 3P HFD Branch Breaker 1 SPD Monitor Visible Through Panel Door - Special Trim 1 SPD Factory Cable Connected to 30A Branch Breaker 1 Surge Protective Device, 120 kA SPD Series - Standard w/ Surge Counter 1 Copper Main Bus, 400 Amps 1 Std. Bolted Al Ground Bar (Al/Cu Cable) 1 Panel Nameplate - White with Black Letters 1 Complete Assembly 1 Type 1 Enclosure: Non Std Box 1 EZ Trim, Door in Door, Concealed Hardware: Special Trim Dimensions: 20"W x 5.75"D x 72"H ** Part# RAKN0731X4K1 1 Cellwatch Battery Monitoring System for (105) SBL200-12i Batteries. Includes: (1) ISK-M 36 Main Kit (1) ISK-S 36 String Kit (1) 701027 - iBMU Wall Mounting Kit (1) 116002 - Single Fiber wire (66 Ft.) 1 Maintenance Bypass Output Lug Modification, Cellwatch electrical connections and Panelboard Installation. 1 Cellwatch Installation and Commissioning The contractor shall provide all equipment, tools, supplies, transportation, supervision, management, and other incidentals necessary to modify the existing Uninterruptable Power Supply (UPS) systems providing critical power to support the USAFE Warrior Preparation Center building 710. The UPS protected, mission critical loads connected to the output of the three Eaton (Powerware) 9390 Uninterruptable Power Supply (UPS) systems will be systematically be reconnected to the output of the Eaton (Powerware) 9315 - 400 kVA UPS. The existing 400 kVA UPS maintenance bypass panel (MBP) located in room A01 will be modified to allow additional load connections. The loads which are currently supported by three non-operational 60 kVA UPSs, located in room A03, will be reconnected to the larger 400 kVA UPS system which is operational. The modification of the MBP and the reconnection of the loads on the 60 kVA UPSs to the 400 kVA UPS will be coordinated with the end users as this will require an outage to those loads. After the loads that are supported by the three 60 kVA UPSs have been reconnected to the larger 400 kVA UPS, the contractor will remove and dispose of the three 60 kVA UPS systems (3 UPS modules, 3 battery cabinets, and 3 MBPs). In addition, the contractor shall provide and install a battery monitoring system designed to work with the Eaton 9315 - 400 kVA UPS system. This will include mounting all equipment for the battery monitoring system, installing tabbed washers on all battery connections, installing the required communications wiring, and configuring the battery program for the battery system at building 710. The battery monitoring system will allow the end users to monitor the health of all batteries within the 400 kVA UPS system, and alert the users of changing battery internal characteristics which may cause failure of the UPS system to protect the mission critical loads. Contractor will remove and dispose of old batteries. This notice of intent is NOT a request for quote; however, all interested persons that identify to the Contracing Officer their intent and capabilities to satisfy the Government's requirement with commercial items and are received within 15 days after the date of publication of this synopsis will be considered by the Government. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be consisered solely for the purpose of determining whether to conduct a competitive procurement. For specific questions, please contact the Contract Specialist, Mrs. Susanne Schorr, at susanne.schorr.de@us.af.mil or telephone (314)536-6611, or the Contracting Officer, Mr. Andrew Feutz, at andrew.feutz@us.af.mil or telephone (314)536-7999.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/b4db68a5b6342bbb947842321454d82c)
 
Place of Performance
Address: Warrior Preparation Center (WPC) Kaiserstrasse 84, Bldg 708, Room109, ATTN: WPC POC: Mr. Victor Waters, Kaiserslautern, Einsiedlerhof, Non-U.S., 67661, Germany
 
Record
SN03628960-W 20150131/150129235625-b4db68a5b6342bbb947842321454d82c (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.