AWARD

Y -- Fort Hood VOLAR Barracks and Central Energy Plant (CEP)Renovations, Fort Hood, Texas

Notice Date
1/30/2015
 
Notice Type
Award Notice
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
USACE District, Fort Worth, PO Box 17300/819 Taylor Street, Fort Worth, TX 76102-0300
 
ZIP Code
76102-0300
 
Solicitation Number
W9126G-14-R-0017
 
Response Due
3/21/2014
 
Archive Date
3/1/2015
 
Point of Contact
Richard Feller, 817-886-1165
 
E-Mail Address
USACE District, Fort Worth
(richard.feller@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Award Number
W9126G-15-C-0009
 
Award Date
1/29/2015
 
Awardee
GUYCO, INC. (056303894) <br> 175 PRIVATE ROAD 3020 <br> LAMPASAS, TX 76550
 
Award Amount
$75,493,905.00
 
Line Number
0001 - 0014
 
Description
Project Description includes the design and construction for the whole block revitalization of the west 39000 block, to include Barracks Buildings 39004, 39005, 39006, 39007, 39012, 39013, 39017 and CEP 39015, renovation of laundry facilities in each barracks, replacement of distribution piping, water and sewer lines to all buildings within the west 39000 block, sidewalk replacement, parking lot reconfiguration and reconstruction, and landscaping. All barracks shall be designed and constructed to house one soldier per room under normal conditions, but the design shall also support two soldiers per room under surge conditions. This project includes the demo of chilled water and steam piping to all buildings supported by the CEP and replacement with a condenser water loop system for ground source heat pumps in the barracks and a heating water loop for domestic hot water. This project also requires providing 40% domestic hot water with solar for the barracks and solar water heating at the central energy plant for the heating water loop. Provisions shall be made for future connection of Headquarters Building 39021 and 39022 to the new condenser water loop.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA63/W9126G-14-R-0017/listing.html)
 
Record
SN03629857-W 20150201/150130235202-724cfd7f4bb0de7ca6338c9e46100688 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.